Academic Journal

Effective Increasing of NPP Reliability Introducing the Active Monitoring System of Block Construction Stress-Strain State

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Effective Increasing of NPP Reliability Introducing the Active Monitoring System of Block Construction Stress-Strain State
Συγγραφείς: A. A. Zemlyanskij, V. P. Grigorenko, K. A. Zemlyanskij, S. A. Dubnov
Πηγή: Глобальная ядерная безопасность, Vol 0, Iss 1, Pp 38-47 (2022)
Στοιχεία εκδότη: Национальный исследовательский ядерный университет МИФИ, 2022.
Έτος έκδοσης: 2022
Συλλογή: LCC:Nuclear engineering. Atomic power
Θεματικοί όροι: защитные барьеры, надежность, магнитометрические датчики, мониторинг строительных конструкций, остаточные напряжения, protective barriers, reliability, magnetometric sensors, monitoring of building structures, residual stresses, Nuclear engineering. Atomic power, TK9001-9401
Περιγραφή: All nuclear power facilities are unique facilities and are simultaneously identified according to STO 1.1.1.02.009.0873-2017 "Ensuring Safety in the Operation of Buildings and Structures of Nuclear Power Plants" as hazardous production facilities with an increased level of responsibility. In this connection, according to the authors, as well as international and domestic experts, the sixth protective barrier should be promptly introduced into the NPP safety system in the form of a system of active monitoring of irreplaceable load-bearing and enclosing structures of the reactor and turbine compartment. The paper substantiates the fact that the current monitoring systems do not allow reliable and effective assessment of the level of VAT of structures, as well as do not allow to assess the level of "residual" stresses, the presence of which in practice may also lead to pre-emergency and emergency situations. To solve this problem the article develops an innovative system of VAT monitoring of both metal and reinforced concrete bearing structures, which is completely devoid of shortcomings of traditional monitoring systems, and which also has a number of undeniable advantages. The proposed monitoring system is developed on the basis of the Forster effect, which is based on the dependence of the relative magnetic permeability of ferromagnetic media on the level of operating stresses in the material. The authors obtained patent No. 2295118 for the developed monitoring system, which testifies to the level of efficiency of innovative solution of this problem. In general, the use of the proposed system as the sixth barrier of protection will in practice prevent any external, pre-accident or emergency situation at the NPP with simultaneous increase of safety and reliability of operation of the NPP after the extension of its operation life.
Τύπος εγγράφου: article
Περιγραφή αρχείου: electronic resource
Γλώσσα: English
Russian
ISSN: 2305-414X
2499-9733
Relation: https://glonucsec.elpub.ru/jour/article/view/132; https://doaj.org/toc/2305-414X; https://doaj.org/toc/2499-9733
DOI: 10.26583/gns-2020-01-04
Σύνδεσμος πρόσβασης: https://doaj.org/article/205a0ebaee144ff1b0ee396b310ce67c
Αριθμός Καταχώρησης: edsdoj.205a0ebaee144ff1b0ee396b310ce67c
Βάση Δεδομένων: Directory of Open Access Journals
Περιγραφή
ISSN:2305414X
24999733
DOI:10.26583/gns-2020-01-04