| Τίτλος: |
Resonance frequency analysis-reliability in third generation instruments: Osstell mentor R |
| Συγγραφείς: |
Herrero-Climent, Mariano, Albertini, Matteo, Ríos-Santos, J.V., Lázaro-Calvo, Pedro, Fernández Palacín, Ana, Bullon, Pedro |
| Συνεισφορές: |
Universidad de Sevilla. Departamento de Estomatología, Universidad de Sevilla. Departamento de Medicina Preventiva y Salud Pública |
| Στοιχεία εκδότη: |
Medicina oral S.L |
| Έτος έκδοσης: |
2024 |
| Συλλογή: |
idUS - Deposito de Investigación Universidad de Sevilla |
| Θεματικοί όροι: |
Dental implants, RFA, ISQ, Implant stability, Osstell |
| Περιγραφή: |
Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive measurements were registered with each transducer. Results: Average ISQ varied from 72.43 to 72.60 and 73.26 in the first, second and third measurements, respectively with the SamrtPeg I and from 72.98 to 73.26 and 73.74 in the first, second and third measurements, respectively with the SamrtPeg II . Exactly equal values were observed in 10.43 and 12.1% of the cases with Smart-Pegs I and II, respectively. The intraclass correlation coefficient was 0.96 and 0.96 for Smart Pegs I and II, respectively. Repeatability and reproducibility was 0.97 for both Smart-Pegs I and II. Conclusions: The RFA system contributed by Osstell Mentor® renders almost perfect reproducibility and repeatability, as proven by statistical analysis carried out by means of ICC with 95% confidence level. This instrument contributes highly reliable RFA measurements in dental implants. |
| Τύπος εγγράφου: |
article in journal/newspaper |
| Γλώσσα: |
English |
| Relation: |
Medicina oral, patología oral y cirugía bucal, 17 (5), E801-E806.; http://www.medicinaoral.com/pubmed/medoralv17_i5_p801.pdf; https://idus.us.es/handle//11441/161829 |
| Διαθεσιμότητα: |
https://idus.us.es/handle//11441/161829 |
| Rights: |
info:eu-repo/semantics/openAccess |
| Αριθμός Καταχώρησης: |
edsbas.C946FC35 |
| Βάση Δεδομένων: |
BASE |