Academic Journal

In vitro comparison of dental implant site preparation with ultrasonic system and conventional rotatory system

Bibliographic Details
Title: In vitro comparison of dental implant site preparation with ultrasonic system and conventional rotatory system
Authors: Lanata‐Flores, A., Nascimento, E.H.L., Goulart, D.R., Haiter‐Neto, F., de Moraes, M., de Albergaria‐Barbosa, J.R.
Source: Oral Surgery ; volume 13, issue 2, page 108-116 ; ISSN 1752-2471 1752-248X
Publisher Information: Wiley
Publication Year: 2019
Collection: Wiley Online Library (Open Access Articles via Crossref)
Description: Aim To compare in vitro the site preparation of dental implant using a rotatory system and an ultrasonic system by evaluating the variability of temperature, time and primary stability that is provided by the different sequences of dental implant drills and tips. Materials and methods Sixteen osteotomies were performed with different sequences of drills (Initial, Titamax 2.0, 2/3 and 3.0) for the rotatory group (RG) and tips (IM1S, IM2P, IM2/3, IM3P) for the ultrasonic group (UG) on bovine cortical‐cancellous bone samples. Micro‐CT images were acquired to assess bone microarchitecture and bone mineral density of each sample to guarantee similar bone conditions. For the RG, the osteotomies were performed with a dental implant contra‐angle handpiece at 800 rpm and 50 N/cm maximum torque using an implant micromotor. For the UG, the osteotomies were performed using a Piezosurgery3 system with the respective tip. The temperature was measured and four implants 3.75 × 11 Titamax were installed in each group to measure the final torque. Results For the RG, the following mean values were found: 22.87 s, 24.2°C superficial temperature, 27.6°C perforation temperature and 32.30 N/cm torque. The UG values were 72.9 s, 26.6°C superficial temperature, 32.1°C perforation temperature and 22.60 N/cm torque. Conclusions Rotatory and ultrasonic systems are effective methods for implant site preparation with satisfactory outcomes. For cortical‐cancellous preparation sites, the drills of the RG were related to lower temperatures and less time for osteotomy. Thus, the use of rotatory systems is preferred due to the heat differential generated during the dental implant sites preparation.
Document Type: article in journal/newspaper
Language: English
DOI: 10.1111/ors.12460
Availability: https://doi.org/10.1111/ors.12460
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1111%2Fors.12460
https://onlinelibrary.wiley.com/doi/pdf/10.1111/ors.12460
https://onlinelibrary.wiley.com/doi/full-xml/10.1111/ors.12460
Rights: http://onlinelibrary.wiley.com/termsAndConditions#vor
Accession Number: edsbas.7BDB658F
Database: BASE
Description
DOI:10.1111/ors.12460