Academic Journal

Continuous mobile measurement of camptocormia angle using four accelerometers

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Continuous mobile measurement of camptocormia angle using four accelerometers
Συγγραφείς: Naderi Beni, Kamran, Knutzen, K., Kuhtz-Buschbeck, J. P., Margraf, N. G., Rieger, Robert
Πηγή: http://lobid.org/resources/99370677024006441#!, 62(12):3637-3652.
Έτος έκδοσης: 2024
Συλλογή: Publisso (ZB MED-Publikationsportal Lebenswissenschaften)
Θεματικοί όροι: Wearable, Posture/physiology [MeSH], Adult [MeSH], Accelerometer, Humans [MeSH], Wearable Electronic Devices [MeSH], Muscular Atrophy, Spinal/diagnosis [MeSH], Camptocormia, Accelerometry/instrumentation [MeSH], Original Article, Malleolus method, Male [MeSH], Home assessment, Spinal Curvatures/physiopathology [MeSH], IMU, Perpendicular method, Accelerometry/methods [MeSH], Spinal/physiopathology [MeSH], Parkinson’s disease
Περιγραφή: AbstractCamptocormia, a severe flexion deformity of the spine, presents challenges in monitoring its progression outside laboratory settings. This study introduces a customized method utilizing four inertial measurement unit (IMU) sensors for continuous recording of the camptocormia angle (CA), incorporating both the consensual malleolus and perpendicular assessment methods. The setup is wearable and mobile and allows measurements outside the laboratory environment. The practicality for measuring CA across various activities is evaluated for both the malleolus and perpendicular method in a mimicked Parkinson disease posture. Multiple activities are performed by a healthy volunteer. Measurements are compared against a camera-based reference system. Results show an overall root mean squared error (RMSE) of 4.13° for the malleolus method and 2.71° for the perpendicular method. Furthermore, patient-specific calibration during the standing still with forward lean activity significantly reduced the RMSE to 2.45° and 1.68° respectively. This study presents a novel approach to continuous CA monitoring outside the laboratory setting. The proposed system is suitable as a tool for monitoring the progression of camptocormia and for the first time implements the malleolus method with IMU. It holds promise for effectively monitoring camptocormia at home.
Τύπος εγγράφου: article in journal/newspaper
Γλώσσα: English
Relation: https://repository.publisso.de/resource/frl:6520175; https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569011/
DOI: 10.1007/s11517-024-03149-1
Διαθεσιμότητα: https://repository.publisso.de/resource/frl:6520175
https://doi.org/10.1007/s11517-024-03149-1
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569011/
Rights: https://creativecommons.org/licenses/by/4.0/
Αριθμός Καταχώρησης: edsbas.34B46D5B
Βάση Δεδομένων: BASE
Περιγραφή
DOI:10.1007/s11517-024-03149-1