Academic Journal

The correlation of urea and creatinine concentrations in sweat and saliva with plasma during hemodialysis: an observational cohort study: an observational cohort study

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: The correlation of urea and creatinine concentrations in sweat and saliva with plasma during hemodialysis: an observational cohort study: an observational cohort study
Συγγραφείς: Sophie Adelaars, Constantijn J.A.M. Konings, Lieke Cox, Eva Boonen, Massimo Mischi, R. Arthur Bouwman, Daan van de Kerkhof
Πηγή: Clinical Chemistry and Laboratory Medicine (CCLM). 62:1118-1125
Στοιχεία εκδότη: Walter de Gruyter GmbH, 2024.
Έτος έκδοσης: 2024
Θεματικοί όροι: Male, Adult, Urea/analysis, Biomarkers/analysis, Sweat/chemistry, Kidney Failure, Cohort Studies, hemodialysis at home, Renal Dialysis, Humans, Urea, Saliva, Sweat, Aged, biosensors for sweat analysis, Saliva/chemistry, Creatinine/blood, Middle Aged, continuous monitoring, diagnostics of urea in sweat and saliva, Chronic/therapy, 3. Good health, non-invasive monitoring, Creatinine, Kidney Failure, Chronic, Female, Biomarkers
Περιγραφή: Objectives Urea and creatinine concentrations in plasma are used to guide hemodialysis (HD) in patients with end-stage renal disease (ESRD). To support individualized HD treatment in a home situation, there is a clinical need for a non-invasive and continuous alternative to plasma for biomarker monitoring during and between cycles of HD. In this observational study, we therefore established the correlation of urea and creatinine concentrations between sweat, saliva and plasma in a cohort of ESRD patients on HD. Methods Forty HD patients were recruited at the Dialysis Department of the Catharina Hospital Eindhoven. Sweat and salivary urea and creatinine concentrations were analyzed at the start and at the end of one HD cycle and compared to the corresponding plasma concentrations. Results A decrease of urea concentrations during HD was observed in sweat, from 27.86 mmol/L to 12.60 mmol/L, and saliva, from 24.70 mmol/L to 5.64 mmol/L. Urea concentrations in sweat and saliva strongly correlated with the concentrations in plasma (ρ 0.92 [p Conclusions The results illustrate a proof of principle of urea measurements in sweat and saliva to monitor HD adequacy in a non-invasive and continuous manner. Biosensors enabling urea monitoring in sweat or saliva could fill in a clinical need to enable at-home HD for more patients and thereby decrease patient burden.
Τύπος εγγράφου: Article
Γλώσσα: English
ISSN: 1437-4331
1434-6621
DOI: 10.1515/cclm-2023-1285
Σύνδεσμος πρόσβασης: https://pubmed.ncbi.nlm.nih.gov/38253354
https://research.tue.nl/en/publications/00bd62b9-b233-4d36-b0b4-e28b71c26e98
https://doi.org/10.1515/cclm-2023-1285
Rights: CC BY
Αριθμός Καταχώρησης: edsair.doi.dedup.....2bd098bdbad7bda5d55ee2c44f5c8306
Βάση Δεδομένων: OpenAIRE
Περιγραφή
ISSN:14374331
14346621
DOI:10.1515/cclm-2023-1285