ПРУД-ОХЛАДИТЕЛЬ НОВОВОРОНЕЖСКОЙ АТОМНОЙ ЭЛЕКТРОСТАНЦИИ КАК ПРИРУСЛОВОЙ ВОДОЕМ ДОНА: ПРЕИМУЩЕСТВА И ВОЗНИКАЮЩИЕ ПРОБЛЕМЫ
| Τίτλος: | ПРУД-ОХЛАДИТЕЛЬ НОВОВОРОНЕЖСКОЙ АТОМНОЙ ЭЛЕКТРОСТАНЦИИ КАК ПРИРУСЛОВОЙ ВОДОЕМ ДОНА: ПРЕИМУЩЕСТВА И ВОЗНИКАЮЩИЕ ПРОБЛЕМЫ |
|---|---|
| Στοιχεία εκδότη: | Мониторинг. Наука и технологии, 2019. |
| Έτος έκδοσης: | 2019 |
| Θεματικοί όροι: | filtration, nuclear power plant, грунтовые воды, 13. Climate action, пруд-охладитель, атомная станция, фильтрация, erosion of the river bank, 7. Clean energy, размыв берега, water reservoir-cooler, 6. Clean water, ground water |
| Περιγραφή: | The suggestion to use surface waters as a cooling agent was proposed at one of the stages of nuclear energy development. Subsequently, this technology was abandoned for a number of reasons, first and foremost, for the environmental problems. The paper considers the further negative factor that endangering the integrity of the water reservoir-cooler in the result of the rise of ground water level from the reservoir and break into the steep Bank of the river. There was a paradoxical situation: into the reservoir-cooler located in the floodplain of the Don River a huge volume of water was pumped with the water table 10 meters above than in low-water period. In the end, after 45 years, due to the occurrence of a large water pressure towards the river, there was a landslide process on the left Bank of the Don opposite the water reservoir-cooler. The River bend here accelerates the process. The problem needs to be solved, since the River bend to start moving towards the reservoir-cooler and the city territory tends to be lost. If no decision is taken, the stream-bank erosion will only increase with time. На одном из этапов развития атомной энергетики в качестве охлаждающей воды было предложено использовать поверхностные воды. Впоследствии от этой технологии отказались по ряду причин, в первую очередь, экологических. В статье рассматривается еще один негативный фактор, создающий угрозу целостности пруда-охладителя в результате повышения грунтовых вод от водоема и выпора их в обрывистый берег реки. Сложилась парадоксальная ситуация, в пруд-охладитель, расположенный в пойме Дона, был закачан огромный объем воды с зеркалом воды выше меженного уровня в реке более чем на 10 м. В итоге, через 45 лет за счет возникновения большого напора грунтовой воды в сторону реки возник оползневой процесс на левом берегу Дона напротив пруда-охладителя. Излучина реки в этом месте лишь ускоряет начавшийся процесс. Проблема требует своего разрешения, так как теряется городская территория и излучина начала перемещение в сторону пруда-охладителя. Размыв берега будет только нарастать со временем в случае непринятия решения. №4(42) (2019) |
| Τύπος εγγράφου: | Article |
| Γλώσσα: | Russian |
| DOI: | 10.25714/mnt.2019.42.007 |
| Αριθμός Καταχώρησης: | edsair.doi...........6fdcfaeb8a44e8b4e9d1fcf43235d372 |
| Βάση Δεδομένων: | OpenAIRE |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: edsair DbLabel: OpenAIRE An: edsair.doi...........6fdcfaeb8a44e8b4e9d1fcf43235d372 RelevancyScore: 822 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 822.384155273438 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: ПРУД-ОХЛАДИТЕЛЬ НОВОВОРОНЕЖСКОЙ АТОМНОЙ ЭЛЕКТРОСТАНЦИИ КАК ПРИРУСЛОВОЙ ВОДОЕМ ДОНА: ПРЕИМУЩЕСТВА И ВОЗНИКАЮЩИЕ ПРОБЛЕМЫ – Name: Publisher Label: Publisher Information Group: PubInfo Data: Мониторинг. Наука и технологии, 2019. – Name: DatePubCY Label: Publication Year Group: Date Data: 2019 – Name: Subject Label: Subject Terms Group: Su Data: <searchLink fieldCode="DE" term="%22filtration%22">filtration</searchLink><br /><searchLink fieldCode="DE" term="%22nuclear+power+plant%22">nuclear power plant</searchLink><br /><searchLink fieldCode="DE" term="%22грунтовые+воды%22">грунтовые воды</searchLink><br /><searchLink fieldCode="DE" term="%2213%2E+Climate+action%22">13. Climate action</searchLink><br /><searchLink fieldCode="DE" term="%22пруд-охладитель%22">пруд-охладитель</searchLink><br /><searchLink fieldCode="DE" term="%22атомная+станция%22">атомная станция</searchLink><br /><searchLink fieldCode="DE" term="%22фильтрация%22">фильтрация</searchLink><br /><searchLink fieldCode="DE" term="%22erosion+of+the+river+bank%22">erosion of the river bank</searchLink><br /><searchLink fieldCode="DE" term="%227%2E+Clean+energy%22">7. Clean energy</searchLink><br /><searchLink fieldCode="DE" term="%22размыв+берега%22">размыв берега</searchLink><br /><searchLink fieldCode="DE" term="%22water+reservoir-cooler%22">water reservoir-cooler</searchLink><br /><searchLink fieldCode="DE" term="%226%2E+Clean+water%22">6. Clean water</searchLink><br /><searchLink fieldCode="DE" term="%22ground+water%22">ground water</searchLink> – Name: Abstract Label: Description Group: Ab Data: The suggestion to use surface waters as a cooling agent was proposed at one of the stages of nuclear energy development. Subsequently, this technology was abandoned for a number of reasons, first and foremost, for the environmental problems. The paper considers the further negative factor that endangering the integrity of the water reservoir-cooler in the result of the rise of ground water level from the reservoir and break into the steep Bank of the river. There was a paradoxical situation: into the reservoir-cooler located in the floodplain of the Don River a huge volume of water was pumped with the water table 10 meters above than in low-water period. In the end, after 45 years, due to the occurrence of a large water pressure towards the river, there was a landslide process on the left Bank of the Don opposite the water reservoir-cooler. The River bend here accelerates the process. The problem needs to be solved, since the River bend to start moving towards the reservoir-cooler and the city territory tends to be lost. If no decision is taken, the stream-bank erosion will only increase with time.<br />На одном из этапов развития атомной энергетики в качестве охлаждающей воды было предложено использовать поверхностные воды. Впоследствии от этой технологии отказались по ряду причин, в первую очередь, экологических. В статье рассматривается еще один негативный фактор, создающий угрозу целостности пруда-охладителя в результате повышения грунтовых вод от водоема и выпора их в обрывистый берег реки. Сложилась парадоксальная ситуация, в пруд-охладитель, расположенный в пойме Дона, был закачан огромный объем воды с зеркалом воды выше меженного уровня в реке более чем на 10 м. В итоге, через 45 лет за счет возникновения большого напора грунтовой воды в сторону реки возник оползневой процесс на левом берегу Дона напротив пруда-охладителя. Излучина реки в этом месте лишь ускоряет начавшийся процесс. Проблема требует своего разрешения, так как теряется городская территория и излучина начала перемещение в сторону пруда-охладителя. Размыв берега будет только нарастать со временем в случае непринятия решения.<br />№4(42) (2019) – Name: TypeDocument Label: Document Type Group: TypDoc Data: Article – Name: Language Label: Language Group: Lang Data: Russian – Name: DOI Label: DOI Group: ID Data: 10.25714/mnt.2019.42.007 – Name: AN Label: Accession Number Group: ID Data: edsair.doi...........6fdcfaeb8a44e8b4e9d1fcf43235d372 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsair&AN=edsair.doi...........6fdcfaeb8a44e8b4e9d1fcf43235d372 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.25714/mnt.2019.42.007 Languages: – Text: Russian Subjects: – SubjectFull: filtration Type: general – SubjectFull: nuclear power plant Type: general – SubjectFull: грунтовые воды Type: general – SubjectFull: 13. Climate action Type: general – SubjectFull: пруд-охладитель Type: general – SubjectFull: атомная станция Type: general – SubjectFull: фильтрация Type: general – SubjectFull: erosion of the river bank Type: general – SubjectFull: 7. Clean energy Type: general – SubjectFull: размыв берега Type: general – SubjectFull: water reservoir-cooler Type: general – SubjectFull: 6. Clean water Type: general – SubjectFull: ground water Type: general Titles: – TitleFull: ПРУД-ОХЛАДИТЕЛЬ НОВОВОРОНЕЖСКОЙ АТОМНОЙ ЭЛЕКТРОСТАНЦИИ КАК ПРИРУСЛОВОЙ ВОДОЕМ ДОНА: ПРЕИМУЩЕСТВА И ВОЗНИКАЮЩИЕ ПРОБЛЕМЫ Type: main BibRelationships: IsPartOfRelationships: – BibEntity: Dates: – D: 25 M: 12 Type: published Y: 2019 Identifiers: – Type: issn-locals Value: edsair |
| ResultId | 1 |