Academic Journal

The effect of multiple firings on the dimensional accuracy of monolithic multilayered zirconia crowns manufactured with different shades: An in vitro study.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: The effect of multiple firings on the dimensional accuracy of monolithic multilayered zirconia crowns manufactured with different shades: An in vitro study.
Συγγραφείς: Spiteri, Maxiline, Trang Tran, Thi Ngoc, Attard, Nikolai, Tezulas, Emre
Πηγή: International Journal of Computerized Dentistry; 2026, Vol. 29 Issue 2, p1-38, 38p
Θεματικοί όροι: Dental crowns, Heat treatment, Prosthodontics, Laboratory techniques, Pigments, Statistical accuracy
Περίληψη: Aim: To evaluate the effect of multiple firings and shading on the dimensional accuracy of monolithic multilayered zirconia crowns. Materials and Methods: Forty-five monolithic multilayered zirconia crowns (Cercon HT ML, Dentsply Sirona) were milled in three shades (A1, A2, A4; n=15 each) from a prepared typodont tooth design. After an initial reference scan of the intaglio surface using an intraoral scanner (Primescan, Dentsply Sirona), the crowns were subjected to six firing cycles. The intaglio surface was scanned after the second, fourth, and sixth cycles to record dimensional changes. Dimensional accuracy was quantified using root mean square (RMS) values, and the uniformity of change was quantified with standard deviation (SD) values using the Geomagic Control X software v24.2.0 (Stockholm, Sweden). Data were analysed using a two-way mixed ANOVA and Simple Main Effects Analysis. Results: Repeated firings had a substantial impact on dimensional accuracy (p<0.01), exhibiting a V-shaped pattern. Initially, there was an improvement in fit, followed by subsequent distortion. Although the overall shade effect was not statistically significant (p=0.630), a simple main effects analysis revealed shade-dependent outcomes. Darker shades (A2, A4) demonstrated significant non-linear fluctuations (p<0.05), while shade A1 remained stable (p=0.126). Conclusion: Repeated firings and darker shades increase the material's sensitivity to thermal treatments, causing statistically significant dimensional changes. However, these dimensional fluctuations remain clinically negligible. Clinicians can safely perform multiple corrective firings on these restorations, regardless of shade, without compromising their final fit. [ABSTRACT FROM AUTHOR]
Copyright of International Journal of Computerized Dentistry is the property of Quintessence Publishing Company Inc. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Βάση Δεδομένων: Biomedical Index
FullText Text:
  Availability: 0
Header DbId: edm
DbLabel: Biomedical Index
An: 195513569
RelevancyScore: 1121
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 1121.07458496094
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: The effect of multiple firings on the dimensional accuracy of monolithic multilayered zirconia crowns manufactured with different shades: An in vitro study.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Spiteri%2C+Maxiline%22&quot;&gt;Spiteri, Maxiline&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Trang+Tran%2C+Thi+Ngoc%22&quot;&gt;Trang Tran, Thi Ngoc&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Attard%2C+Nikolai%22&quot;&gt;Attard, Nikolai&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Tezulas%2C+Emre%22&quot;&gt;Tezulas, Emre&lt;/searchLink&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: International Journal of Computerized Dentistry; 2026, Vol. 29 Issue 2, p1-38, 38p
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Dental+crowns%22&quot;&gt;Dental crowns&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Heat+treatment%22&quot;&gt;Heat treatment&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Prosthodontics%22&quot;&gt;Prosthodontics&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Laboratory+techniques%22&quot;&gt;Laboratory techniques&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Pigments%22&quot;&gt;Pigments&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Statistical+accuracy%22&quot;&gt;Statistical accuracy&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Aim: To evaluate the effect of multiple firings and shading on the dimensional accuracy of monolithic multilayered zirconia crowns. Materials and Methods: Forty-five monolithic multilayered zirconia crowns (Cercon HT ML, Dentsply Sirona) were milled in three shades (A1, A2, A4; n=15 each) from a prepared typodont tooth design. After an initial reference scan of the intaglio surface using an intraoral scanner (Primescan, Dentsply Sirona), the crowns were subjected to six firing cycles. The intaglio surface was scanned after the second, fourth, and sixth cycles to record dimensional changes. Dimensional accuracy was quantified using root mean square (RMS) values, and the uniformity of change was quantified with standard deviation (SD) values using the Geomagic Control X software v24.2.0 (Stockholm, Sweden). Data were analysed using a two-way mixed ANOVA and Simple Main Effects Analysis. Results: Repeated firings had a substantial impact on dimensional accuracy (p&lt;0.01), exhibiting a V-shaped pattern. Initially, there was an improvement in fit, followed by subsequent distortion. Although the overall shade effect was not statistically significant (p=0.630), a simple main effects analysis revealed shade-dependent outcomes. Darker shades (A2, A4) demonstrated significant non-linear fluctuations (p&lt;0.05), while shade A1 remained stable (p=0.126). Conclusion: Repeated firings and darker shades increase the material&#39;s sensitivity to thermal treatments, causing statistically significant dimensional changes. However, these dimensional fluctuations remain clinically negligible. Clinicians can safely perform multiple corrective firings on these restorations, regardless of shade, without compromising their final fit. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of International Journal of Computerized Dentistry is the property of Quintessence Publishing Company Inc. and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edm&AN=195513569
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.3290/j.ijcd.b7047011
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 38
        StartPage: 1
    Subjects:
      – SubjectFull: Dental crowns
        Type: general
      – SubjectFull: Heat treatment
        Type: general
      – SubjectFull: Prosthodontics
        Type: general
      – SubjectFull: Laboratory techniques
        Type: general
      – SubjectFull: Pigments
        Type: general
      – SubjectFull: Statistical accuracy
        Type: general
    Titles:
      – TitleFull: The effect of multiple firings on the dimensional accuracy of monolithic multilayered zirconia crowns manufactured with different shades: An in vitro study.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Spiteri, Maxiline
      – PersonEntity:
          Name:
            NameFull: Trang Tran, Thi Ngoc
      – PersonEntity:
          Name:
            NameFull: Attard, Nikolai
      – PersonEntity:
          Name:
            NameFull: Tezulas, Emre
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: 2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 14634201
          Numbering:
            – Type: volume
              Value: 29
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: International Journal of Computerized Dentistry
              Type: main
ResultId 1