Evaluation of a Faraday cup-style detector as a beam diagnostic system for ultra-high dose rate (FLASH) electron beams.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Evaluation of a Faraday cup-style detector as a beam diagnostic system for ultra-high dose rate (FLASH) electron beams.
Συγγραφείς: Lopez A; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.; The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA., Baikalov A; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.; Department of Radiation Oncology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.; Institute of Radiation Medicine, Helmholtz Zentrum München GmbH, German Research Center for Environmental Health, Neuherberg, Germany., Liu K; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.; The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA., Esplen N; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA., Bartzsch S; Department of Radiation Oncology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.; Institute of Radiation Medicine, Helmholtz Zentrum München GmbH, German Research Center for Environmental Health, Neuherberg, Germany., Schüler E; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.; The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA.
Πηγή: Journal of applied clinical medical physics [J Appl Clin Med Phys] 2026 Oct; Vol. 27 (10), pp. e70819.
Τύπος έκδοσης: Journal Article; Evaluation Study
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Wiley on behalf of American Association of Physicists in Medicine Country of Publication: United States NLM ID: 101089176 Publication Model: Print Cited Medium: Internet ISSN: 1526-9914 (Electronic) Linking ISSN: 15269914 NLM ISO Abbreviation: J Appl Clin Med Phys Subsets: MEDLINE
Imprint Name(s): Publication: 2017- : Malden, MA : Wiley on behalf of American Association of Physicists in Medicine
Original Publication: Reston, VA : American College of Medical Physics, c2000-
Ιατρικοί όροι (MeSH): Particle Accelerators*/instrumentation , Radiometry*/instrumentation , Radiometry*/methods , Radiotherapy Planning, Computer-Assisted*/methods , Quality Assurance, Health Care*/standards , Electrons* , Phantoms, Imaging*, Humans ; Radiotherapy Dosage ; Equipment Design
Περίληψη: Background: Beam diagnostic systems are essential for the development and quality assurance of ultra-high dose rate (UHDR) radiation sources to enable reliable delivery of FLASH radiotherapy (RT). Critically, suitable beam diagnostic systems for electron FLASH sources are lacking.
Purpose: In this study, we evaluated a Faraday cup-style beam collector (BC), the BC-145-Al, on an UHDR electron linac for FLASH-RT applications.
Methods: The BC performance was benchmarked against a reference alternating-current current transformer (ACCT) across a wide range of beam currents and pulse structures to test the BC's charge linearity and signal resolution capabilities. Two termination impedances were tested: 200 kΩ and 13 Ω.
Results: The highly time-resolved signal of the BC was charge-proportional when terminated at 200 kΩ and current-proportional when terminated at 13 Ω, agreeing well with the time-resolved ACCT signal. The cumulative signals from the BC and ACCT showed excellent agreement, maintaining linearity with a deviation of less than ± 0.5% over 50 consecutive pulses (4-µs pulse width, 120-Hz pulse repetition frequency [PRF]). The BC/ACCT signal ratio remained stable within ± 0.5% as the PRF increased from 5 to 120 Hz at constant pulse width. Pulse width measurements from both detectors were also consistent within ± 0.5% across all nominal pulse width values (0.5-4 µs). When the charge per pulse was modulated by either increasing the pulse width or decreasing the source-to-surface distance (from 32.3 to 19.3 cm), the BC signal remained approximately linear with respect to the ACCT signal; however, the BC/ACCT ratio deviated by up to ± 6% across this range.
Conclusions: The BC produced highly time-resolved absolute charge measurements of a pulsed UHDR electron beam across a large range of beam parameters. These results support its potential as a beam diagnostic system for both preclinical studies and clinical applications of electron FLASH radiotherapy.
(© 2026 The Author(s). Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine.)
References: Med Phys. 2017 Mar;44(3):1157-1167. (PMID: 28094853)
Phys Med Biol. 2023 Nov 23;68(23):. (PMID: 37934049)
Med Phys. 2022 Aug;49(8):5513-5522. (PMID: 35652248)
Med Phys. 2023 Nov;50(11):7252-7262. (PMID: 37403570)
Radiother Oncol. 2019 Oct;139:11-17. (PMID: 31253466)
Phys Med Biol. 2021 Feb 09;66(4):045015. (PMID: 33361551)
Med Phys. 2022 Mar;49(3):1902-1910. (PMID: 35064594)
Med Phys. 2022 Jul;49(7):4912-4932. (PMID: 35404484)
Med Phys. 2024 Dec;51(12):9275-9289. (PMID: 39311014)
Med Phys. 2025 Feb;52(2):1207-1223. (PMID: 39462477)
Med Phys. 2021 Aug;48(8):4472-4484. (PMID: 34077590)
Phys Med Biol. 2020 Dec 04;65(23):23TR03. (PMID: 32721941)
Med Phys. 2022 Mar;49(3):2082-2095. (PMID: 34997969)
J Appl Clin Med Phys. 2026 Oct;27(10):e70819. (PMID: 42786706)
Phys Med Biol. 2021 Jun 08;66(12):. (PMID: 33906166)
Med Phys. 2018 Feb;45(2):863-874. (PMID: 29206287)
Med Phys. 1999 Sep;26(9):1847-70. (PMID: 10505874)
Med Phys. 2022 Mar;49(3):1831-1838. (PMID: 35066878)
J Appl Clin Med Phys. 2023 Feb;24(2):e13891. (PMID: 36601691)
Int J Radiat Oncol Biol Phys. 2025 Apr 01;121(5):1372-1383. (PMID: 39615658)
Radiat Res. 2020 Dec 1;194(6):580-586. (PMID: 33348371)
Med Phys. 2024 Jan;51(1):494-508. (PMID: 37696271)
Med Phys. 2022 Jul;49(7):4682-4692. (PMID: 35462420)
Int J Radiat Oncol Biol Phys. 2023 Aug 1;116(5):1202-1217. (PMID: 37121362)
Rev Sci Instrum. 2020 Nov 1;91(11):113303. (PMID: 33261456)
Med Phys. 2012 May;39(5):2447-55. (PMID: 22559615)
Cancers (Basel). 2023 Jul 30;15(15):. (PMID: 37568699)
Radiat Res. 2024 Mar 1;201(3):252-260. (PMID: 38308528)
Grant Information: P30 CA016672 United States CA NCI NIH HHS; R01 CA266673 United States CA NCI NIH HHS; P30 CA016672 MD Anderson's Division of Radiation Oncology; by Cancer Center Support (Core); R01CA266673 United States NH NIH HHS
Contributed Indexing: Keywords: FLASH radiotherapy; Faraday cup; beam diagnostics; ultra‐high dose rate
Entry Date(s): Date Created: 20260925 Date Completed: 20260925 Latest Revision: 20260929
Update Code: 20260929
PubMed Central ID: PMC13612965
DOI: 10.1002/acm2.70819
PMID: 42786706
Βάση Δεδομένων: MEDLINE
Περιγραφή
ISSN:1526-9914
DOI:10.1002/acm2.70819