Safety and Efficacy of Right- Versus Left-Sided Transvenous Lead Extraction.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Safety and Efficacy of Right- Versus Left-Sided Transvenous Lead Extraction.
Συγγραφείς: Molitor N; Division of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland., Wiederkehr C; Division of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland., Steffel J; Division of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland., Häberlin A; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.; ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland., Breitenstein A; Division of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland., Hofer D; Division of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.
Πηγή: Journal of cardiovascular electrophysiology [J Cardiovasc Electrophysiol] 2026 Oct; Vol. 37 (10), pp. 2341-2347. Date of Electronic Publication: 2026 Sep 19.
Τύπος έκδοσης: Journal Article; Comparative Study
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Blackwell Country of Publication: United States NLM ID: 9010756 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1540-8167 (Electronic) Linking ISSN: 10453873 NLM ISO Abbreviation: J Cardiovasc Electrophysiol Subsets: MEDLINE
Imprint Name(s): Publication: Malden, MA : Blackwell
Original Publication: Mt. Kisco, N.Y. : Futura Pub., c1990-
Ιατρικοί όροι (MeSH): Device Lead Extraction*/adverse effects , Device Removal*/adverse effects , Device Removal*/methods , Pacemaker, Artificial*/adverse effects , Defibrillators, Implantable*/adverse effects , Prosthesis-Related Infections*/surgery , Prosthesis-Related Infections*/diagnostic imaging , Prosthesis-Related Infections*/diagnosis, Humans ; Retrospective Studies ; Treatment Outcome ; Female ; Male ; Time Factors ; Risk Factors ; Aged ; Middle Aged ; Risk Assessment ; Switzerland ; Aged, 80 and over
Περίληψη: Background and Aims: Transvenous lead extraction (TLE) is increasingly performed for malfunction or infection of cardiac implantable electronic devices. Because of anatomic differences, TLE for right-sided (RS) electrodes may differ in outcome. This study aimed to evaluate whether RS TLE differs in patient characteristics and outcomes compared to left-sided TLE.
Methods: We retrospectively analyzed patients who underwent TLE at the University Hospital Zurich from 2013 until 2023 regarding clinical and radiological success and complications.
Results: A total of 556 patients underwent 568 TLE from January 2013 until December 2023. Patients with RS TLE procedures (n = 147, 25.9%) were older, more often PM-dependent, had longer lead dwell time, more leads with passive fixation and were more often extracted for infection. RS TLE procedures had a longer procedure duration (130 vs. 108 min, p = 0.002), more often needed a snare-bailout strategy (22% vs. 10%, p = 0.0.45), resulted in lower radiological success rates (88.4% vs. 93.8%, p = 0.045) and more major as well as minor complication rates.
Conclusion: In our retrospective single-center analysis, RS TLE Procedures were more challenging concerning patient characteristics and resulted in lower TLE success as well as higher complication rates.
(© 2026 The Author(s). Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC.)
References: Pacing Clin Electrophysiol. 1999 Sep;22(9):1348-57. (PMID: 10527016)
Heart Rhythm. 2017 Dec;14(12):e503-e551. (PMID: 28919379)
Eur Heart J. 2015 Nov 1;36(41):2793-2867. (PMID: 26320108)
J Am Coll Cardiol. 2010 Feb 9;55(6):579-86. (PMID: 20152562)
J Am Coll Cardiol. 2011 Aug 30;58(10):1001-6. (PMID: 21867833)
Europace. 2009 May;11(5):612-7. (PMID: 19329797)
Heart Rhythm. 2014 Mar;11(3):419-25. (PMID: 24315967)
Heart Rhythm. 2009 Jul;6(7):1085-104. (PMID: 19560098)
Contributed Indexing: Keywords: complication; lead extraction; right; right‐sided; success
Entry Date(s): Date Created: 20260919 Date Completed: 20261014 Latest Revision: 20261016
Update Code: 20261016
PubMed Central ID: PMC13661777
DOI: 10.1111/jce.70497
PMID: 42762509
Βάση Δεδομένων: MEDLINE
Περιγραφή
ISSN:1540-8167
DOI:10.1111/jce.70497