Respiration-Related Catheter Displacement and Physiological Tolerance of High-Frequency Very Low Tidal Volume Ventilation With Peak Pressure Limitation During Atrial Fibrillation Ablation: A Prospective 1-Way Crossover Pilot Study.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Respiration-Related Catheter Displacement and Physiological Tolerance of High-Frequency Very Low Tidal Volume Ventilation With Peak Pressure Limitation During Atrial Fibrillation Ablation: A Prospective 1-Way Crossover Pilot Study.
Συγγραφείς: Ramírez-Paesano CR; Centro Médico Teknon, Quironsalud, Servei Central d'Anestesiología (Anestalia), Barcelona, Spain. Electronic address: cramirez@anestalia.com., Colina-Vargas YA; Centro Médico Teknon, Quironsalud, Servei Central d'Anestesiología (Anestalia), Barcelona, Spain., Teresi L; ICOR, Centro Médico Teknon, Quironsalud, Barcelona, Spain., Penela D; Department of Biomedical Sciences, Humanitas University, Milan, Italy., Falasconi G; ICOR, Centro Médico Teknon, Quironsalud, Barcelona, Spain., Amata F; ICOR, Centro Médico Teknon, Quironsalud, Barcelona, Spain., Tresandi D; Centro Médico Teknon, Quironsalud, Servei Central d'Anestesiología (Anestalia), Barcelona, Spain., Cersosimo A; ICOR, Centro Médico Teknon, Quironsalud, Barcelona, Spain., Olive JR; Centro Médico Teknon, Quironsalud, Servei Central d'Anestesiología (Anestalia), Barcelona, Spain., Soto-Iglesias D; ICOR, Centro Médico Teknon, Quironsalud, Barcelona, Spain., Marti-Almor J; ICOR, Centro Médico Teknon, Quironsalud, Barcelona, Spain., Berruezo A; ICOR, Centro Médico Teknon, Quironsalud, Barcelona, Spain.
Πηγή: Journal of cardiothoracic and vascular anesthesia [J Cardiothorac Vasc Anesth] 2026 Nov; Vol. 40 (11), pp. 3540-3552. Date of Electronic Publication: 2026 Jun 24.
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: W.B. Saunders Country of Publication: United States NLM ID: 9110208 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1532-8422 (Electronic) Linking ISSN: 10530770 NLM ISO Abbreviation: J Cardiothorac Vasc Anesth Subsets: MEDLINE
Imprint Name(s): Original Publication: Philadelphia, PA : W.B. Saunders, c1991-
Ιατρικοί όροι (MeSH): Atrial Fibrillation*/surgery , Atrial Fibrillation*/physiopathology , Catheter Ablation*/methods , Catheter Ablation*/adverse effects , Tidal Volume*/physiology , High-Frequency Ventilation*/methods, Humans ; Cross-Over Studies ; Pilot Projects ; Prospective Studies ; Male ; Female ; Middle Aged ; Aged
Περίληψη: Objective: To evaluate whether high-frequency, very low tidal volume ventilation with controlled peak inspiratory pressure limitation (HFvLTV-cPP) is associated with reduced respiration-related catheter displacement during atrial fibrillation (AF) ablation, while maintaining short-term physiological tolerance.
Design: Prospective, single-center, fixed-sequence within-patient crossover pilot study.
Setting: Tertiary electrophysiology center.
Participants: Fifty-two consecutive eligible adult patients undergoing radiofrequency catheter ablation for AF under general anesthesia.
Intervention: Standard ventilation followed by HFvLTV-cPP (50 breaths·min⁻¹, inspiratory-to-expiratory ratio 1:1, tidal volume titrated to minimize catheter displacement, peak inspiratory pressure ≤20 cmH2O), delivered using a standard anesthesia workstation.
Measurements and Main Results: HFvLTV-cPP was associated with a marked reduction in catheter displacement (6.22 ± 2.18 mm v 1.23 ± 0.69 mm; -4.99 mm, p < 0.001), corresponding to ∼80% reduction. Contact force was similar. Partial pressure of carbon dioxide increased from 38.0 ± 4.9 to 49.9 ± 7.2 mmHg, with values >60 mmHg in 9.6% of patients. Oxygenation remained preserved. Plateau pressures were not increased, and driving pressure was lower. Mean arterial pressure decreased after induction but not after HFvLTV-cPP, with modest vasopressor use. No procedural complications occurred. Early recovery was rapid, without early respiratory or neurologic complications.
Conclusions: HFvLTV-cPP was associated with marked motion reduction and short-term physiological tolerance in a selected cohort. These findings represent a mechanistic signal and do not establish clinical benefit or safety. Randomized studies are required.
(Copyright © 2026 Elsevier Inc. All rights reserved.)
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Contributed Indexing: Keywords: anesthesia; atrial fibrillation; catheter ablation; catheter stability; high-frequency, very low tidal ventilation; hypercapnia; mechanical ventilation; peak pressure limitation
Entry Date(s): Date Created: 20260716 Date Completed: 20261013 Latest Revision: 20261013