Academic Journal

Fast and compact scatterometer for ex vivo qualification of low-scattering biological samples.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Fast and compact scatterometer for ex vivo qualification of low-scattering biological samples.
Συγγραφείς: Sarrade A; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Ramsay Générale de Santé, Clinique Monticelli-Velodrome, Marseille, France., El Allam J; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France., Espinas V; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Centre Européen de Recherche en Imagerie Médicale (CERIMED), Aix-Marseille University, CNRS, Marseille, France., Hoffart L; Ramsay Générale de Santé, Clinique Monticelli-Velodrome, Marseille, France., Picard C; Tissue Bank, French Blood Establishment, Marseille, France.; ADES, French Blood Establishment/Aix-Marseille University/CNRS, Marseille, France., David T; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France., Georges G; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France., Deumié C; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Centre Européen de Recherche en Imagerie Médicale (CERIMED), Aix-Marseille University, CNRS, Marseille, France., Siozade Lamoine L; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Centre Européen de Recherche en Imagerie Médicale (CERIMED), Aix-Marseille University, CNRS, Marseille, France., Fade J; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Centre Européen de Recherche en Imagerie Médicale (CERIMED), Aix-Marseille University, CNRS, Marseille, France.
Πηγή: The Review of scientific instruments [Rev Sci Instrum] 2026 Jul 01; Vol. 97 (7).
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: American Institute Of Physics Country of Publication: United States NLM ID: 0405571 Publication Model: Print Cited Medium: Internet ISSN: 1089-7623 (Electronic) Linking ISSN: 00346748 NLM ISO Abbreviation: Rev Sci Instrum Subsets: MEDLINE
Imprint Name(s): Publication: 1933- : Woodbury, N.Y. : American Institute Of Physics
Original Publication: 1930-1932 : Menasha, WI : Optical Society of America
Ιατρικοί όροι (MeSH): Scattering, Radiation* , Cornea*, Humans ; Calibration ; Time Factors ; Equipment Design ; Light
Περίληψη: We present the design, calibration, qualification, and application of a fast and compact scatterometer designed for the characterization of ex vivo human corneas. As an alternative to standard qualification processes and in order to meet the current need for improved reliability of graft qualification, this instrument provides a non-invasive, label-free, and contact-free quantitative means of characterizing corneal grafts, based on back-scattered light diffusometry. The instrument is shown to be capable of detecting BRDF (bidirectional reflectance distribution function) variations of 1.4 × 10-4 sr-1 with a detectivity threshold of 2.0 × 10-3 sr-1, with an overall dynamics >27 dB for the total integrated scattering parameter used for graft quality assessment. We also demonstrate the feasibility of integrating this new technique into tissue bank qualification processes through controlled test experiments reported here.
(© 2026 Author(s). Published under an exclusive license by AIP Publishing.)
Entry Date(s): Date Created: 20260713 Date Completed: 20260713 Latest Revision: 20260713
Update Code: 20260713
DOI: 10.1063/5.0327390
PMID: 42439722
Βάση Δεδομένων: MEDLINE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=10897623&ISBN=&volume=97&issue=7&date=20260701&spage=&pages=&title=The Review of scientific instruments&atitle=Fast%20and%20compact%20scatterometer%20for%20ex%20vivo%20qualification%20of%20low-scattering%20biological%20samples.&aulast=Sarrade%20A&id=DOI:10.1063/5.0327390
    Name: Full Text Finder (for New FTF UI) (ns324271)
    Category: fullText
    Text: Full Text Finder
    MouseOverText: Full Text Finder
Header DbId: cmedm
DbLabel: MEDLINE
An: 42439722
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Fast and compact scatterometer for ex vivo qualification of low-scattering biological samples.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Sarrade+A%22">Sarrade A</searchLink>; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Ramsay Générale de Santé, Clinique Monticelli-Velodrome, Marseille, France.<br /><searchLink fieldCode="AU" term="%22El+Allam+J%22">El Allam J</searchLink>; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.<br /><searchLink fieldCode="AU" term="%22Espinas+V%22">Espinas V</searchLink>; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Centre Européen de Recherche en Imagerie Médicale (CERIMED), Aix-Marseille University, CNRS, Marseille, France.<br /><searchLink fieldCode="AU" term="%22Hoffart+L%22">Hoffart L</searchLink>; Ramsay Générale de Santé, Clinique Monticelli-Velodrome, Marseille, France.<br /><searchLink fieldCode="AU" term="%22Picard+C%22">Picard C</searchLink>; Tissue Bank, French Blood Establishment, Marseille, France.; ADES, French Blood Establishment/Aix-Marseille University/CNRS, Marseille, France.<br /><searchLink fieldCode="AU" term="%22David+T%22">David T</searchLink>; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.<br /><searchLink fieldCode="AU" term="%22Georges+G%22">Georges G</searchLink>; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.<br /><searchLink fieldCode="AU" term="%22Deumié+C%22">Deumié C</searchLink>; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Centre Européen de Recherche en Imagerie Médicale (CERIMED), Aix-Marseille University, CNRS, Marseille, France.<br /><searchLink fieldCode="AU" term="%22Siozade+Lamoine+L%22">Siozade Lamoine L</searchLink>; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Centre Européen de Recherche en Imagerie Médicale (CERIMED), Aix-Marseille University, CNRS, Marseille, France.<br /><searchLink fieldCode="AU" term="%22Fade+J%22">Fade J</searchLink>; Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.; Centre Européen de Recherche en Imagerie Médicale (CERIMED), Aix-Marseille University, CNRS, Marseille, France.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%220405571%22">The Review of scientific instruments</searchLink> [Rev Sci Instrum] 2026 Jul 01; Vol. 97 (7).
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22American+Institute+Of+Physics%22">American Institute Of Physics </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>0405571 <i>Publication Model: </i>Print <i>Cited Medium: </i>Internet <i>ISSN: </i>1089-7623 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200346748%22">00346748 </searchLink><i>NLM ISO Abbreviation: </i>Rev Sci Instrum <i>Subsets: </i>MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: <i>Publication</i>: 1933- : Woodbury, N.Y. : American Institute Of Physics<br /><i>Original Publication</i>: 1930-1932 : Menasha, WI : Optical Society of America
– Name: SubjectMESH
  Label: MeSH Terms
  Group: Su
  Data: <searchLink fieldCode="MM" term="%22Scattering%2C+Radiation%22">Scattering, Radiation*</searchLink> <br /><searchLink fieldCode="MM" term="%22Cornea%22">Cornea*</searchLink><br /><searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22Calibration%22">Calibration</searchLink> ; <searchLink fieldCode="MH" term="%22Time+Factors%22">Time Factors</searchLink> ; <searchLink fieldCode="MH" term="%22Equipment+Design%22">Equipment Design</searchLink> ; <searchLink fieldCode="MH" term="%22Light%22">Light</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: We present the design, calibration, qualification, and application of a fast and compact scatterometer designed for the characterization of ex vivo human corneas. As an alternative to standard qualification processes and in order to meet the current need for improved reliability of graft qualification, this instrument provides a non-invasive, label-free, and contact-free quantitative means of characterizing corneal grafts, based on back-scattered light diffusometry. The instrument is shown to be capable of detecting BRDF (bidirectional reflectance distribution function) variations of 1.4 × 10-4 sr-1 with a detectivity threshold of 2.0 × 10-3 sr-1, with an overall dynamics >27 dB for the total integrated scattering parameter used for graft quality assessment. We also demonstrate the feasibility of integrating this new technique into tissue bank qualification processes through controlled test experiments reported here.<br /> (© 2026 Author(s). Published under an exclusive license by AIP Publishing.)
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: <i>Date Created: </i>20260713 <i>Date Completed: </i>20260713 <i>Latest Revision: </i>20260713
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260713
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1063/5.0327390
– Name: AN
  Label: PMID
  Group: ID
  Data: 42439722
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42439722
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1063/5.0327390
    Languages:
      – Code: eng
        Text: English
    Subjects:
      – SubjectFull: Humans
        Type: general
      – SubjectFull: Calibration
        Type: general
      – SubjectFull: Time Factors
        Type: general
      – SubjectFull: Equipment Design
        Type: general
      – SubjectFull: Light
        Type: general
      – SubjectFull: Scattering, Radiation
        Type: general
      – SubjectFull: Cornea
        Type: general
    Titles:
      – TitleFull: Fast and compact scatterometer for ex vivo qualification of low-scattering biological samples.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Sarrade A
      – PersonEntity:
          Name:
            NameFull: El Allam J
      – PersonEntity:
          Name:
            NameFull: Espinas V
      – PersonEntity:
          Name:
            NameFull: Hoffart L
      – PersonEntity:
          Name:
            NameFull: Picard C
      – PersonEntity:
          Name:
            NameFull: David T
      – PersonEntity:
          Name:
            NameFull: Georges G
      – PersonEntity:
          Name:
            NameFull: Deumié C
      – PersonEntity:
          Name:
            NameFull: Siozade Lamoine L
      – PersonEntity:
          Name:
            NameFull: Fade J
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 07
              Text: 2026 Jul 01
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 1089-7623
          Numbering:
            – Type: volume
              Value: 97
            – Type: issue
              Value: 7
          Titles:
            – TitleFull: The Review of scientific instruments
              Type: main
ResultId 1