Academic Journal

Validation of the Shoebox PureTest audiometry technology for remote data collection in clinical trials.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Validation of the Shoebox PureTest audiometry technology for remote data collection in clinical trials.
Συγγραφείς: Robertson EE; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA. erinrobertson6287@gmail.com., Acosta RJ; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA., Tzoneva G; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA., Redington ER; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA., Wipperman MF; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA., Rai P; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA., Majaj R; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA., Barge R; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA., Drummond MC; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA., Shuldiner AR; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA., Urbanek JK; Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA.
Πηγή: Scientific reports [Sci Rep] 2026 Jun 12; Vol. 16 (1). Date of Electronic Publication: 2026 Jun 12.
Τύπος έκδοσης: Journal Article; Validation Study
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Nature Publishing Group Country of Publication: England NLM ID: 101563288 Publication Model: Electronic Cited Medium: Internet ISSN: 2045-2322 (Electronic) Linking ISSN: 20452322 NLM ISO Abbreviation: Sci Rep Subsets: MEDLINE
Imprint Name(s): Original Publication: London : Nature Publishing Group, copyright 2011-
Ιατρικοί όροι (MeSH): Data Collection*/methods , Audiometry, Pure-Tone*/methods , Audiometry, Pure-Tone*/instrumentation , Audiometry*/methods , Clinical Trials as Topic*, Humans ; Female ; Male ; Adult ; Middle Aged ; Aged ; Reproducibility of Results ; Young Adult
Περίληψη: At present, traditional audiologic assessments are required to be performed in clinics and present a considerable burden to patients and sites (e.g., cost, time), particularly in clinical trials that require numerous longitudinal visits. This study evaluated an iPad-based remote audiometry technology, the Shoebox PureTest, for accuracy and usability, and aimed to determine whether it is fit for use in research and clinical studies. In participants with a wide range of hearing sensitivity, the Shoebox PureTest audiometer was determined to be sufficiently accurate, reliable, and usable, and was statistically equivalent to gold-standard conventional audiometry assessments at frequencies of 500, 1000, 2000, and 4000 Hz. The user experience survey demonstrated that > 80% of users rated the application and usability as 'good', and the overall satisfaction was rated as 'excellent' by 92% of participants. Whilst there are operational considerations for future use in clinical trials, the Shoebox PureTest audiometer has been shown to be a valid alternative to conventional hearing assessments which can be used for the optimization of clinical research studies.
(© 2026. The Author(s).)
Competing Interests: Declarations. Competing interests: All authors are employees and shareholders of Regeneron Pharmaceuticals, Inc.
References: World Health Organization. Deafness and hearing loss, https://www.who.int/news-room/fact-sheets/detail/deafness-and-hearing-loss (2024).
Yamasoba, T. et al. Current concepts in age-related hearing loss: Epidemiology and mechanistic pathways. Hear. Res. 303, 30–38. https://doi.org/10.1016/j.heares.2013.01.021 (2013). (PMID: 10.1016/j.heares.2013.01.021234223123723756)
Bowl, M. R. & Dawson, S. J. Age-related hearing loss. Cold Spring Harb. Perspect. Med. 9, a033217. https://doi.org/10.1101/cshperspect.a033217 (2019). (PMID: 10.1101/cshperspect.a033217302911496671929)
GBD 2019 Hearing Loss Collaborators. Hearing loss prevalence and years lived with disability, 1990-2019: Findings from the Global Burden of Disease Study 2019. Lancet 397, 996–1009. https://doi.org/10.1016/S0140-6736(21)00516-X (2021). (PMID: 10.1016/S0140-6736(21)00516-X)
Clinical Trials.gov. A study of DB-OTO, an adeno-associated virus (AAV) based gene therapy, in children/infants with hearing loss due to otoferlin mutations (CHORD), https://clinicaltrials.gov/study/NCT05788536?term=AAV-OTOF&rank=2 (2024).
Wang, H. et al. Hair cell-specific Myo15 promoter-mediated gene therapy rescues hearing in DFNB9 mouse model. Mol. Ther. Nucleic Acids 35, 102135. https://doi.org/10.1016/j.omtn.2024.102135 (2024). (PMID: 10.1016/j.omtn.2024.1021353840450410883836)
SHOEBOX Ltd. SHOEBOX PureTest, https://www.shoebox.md/products/shoebox-puretest (2024).
Bastianelli, M. et al. Adult validation of a self-administered tablet audiometer. J. Otolaryngol. Head Neck Surg. 48, 59. https://doi.org/10.1186/s40463-019-0385-0 (2019). (PMID: 10.1186/s40463-019-0385-0316991576839098)
Frank, A., Goldlist, S., Mark Fraser, A. E. & Bromwich, M. Validation of SHOEBOX QuickTest hearing loss screening tool in individuals with cognitive impairment. Front. Digit. Health 3, 724997. https://doi.org/10.3389/fdgth.2021.724997 (2021). (PMID: 10.3389/fdgth.2021.724997347131958521917)
Saliba, J. et al. Accuracy of mobile-based audiometry in the evaluation of hearing loss in quiet and noisy environments. Otolaryngol. Head Neck Surg. 156, 706–711. https://doi.org/10.1177/0194599816683663 (2017). (PMID: 10.1177/019459981668366328025906)
Thompson, G. P., Sladen, D. P., Borst, B. J. & Still, O. L. Accuracy of a tablet audiometer for measuring behavioral hearing thresholds in a clinical population. Otolaryngol. Head Neck Surg. 153, 838–842. https://doi.org/10.1177/0194599815593737 (2015). (PMID: 10.1177/019459981559373726183518)
Nieman, C. L. et al. Prevalence of hearing loss and hearing aid use among persons living with dementia in the US. JAMA Netw. Open 7, e2440400. https://doi.org/10.1001/jamanetworkopen.2024.40400 (2024). (PMID: 10.1001/jamanetworkopen.2024.404003943230411581568)
Hu, M. et al. Collecting objective measures of visual and auditory function in a national in-home survey of older adults. J. Surv. Stat. Methodol. 9, 309–334. https://doi.org/10.1093/jssam/smaa044 (2021). (PMID: 10.1093/jssam/smaa044338696408027590)
Stephan, Y., Sutin, A. R. & Terracciano, A. Personality traits and the risk of sensory impairment: Evidence from the National Health and Aging Trends Study. J. Psychosom. Res. 173, 111459. https://doi.org/10.1016/j.jpsychores.2023.111459 (2023). (PMID: 10.1016/j.jpsychores.2023.1114593765712510591274)
US Department of Labor. 1910.95 - Occupational noise exposure, https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.95?utm_source=chatgpt.com (2008).
Liljequist, D., Elfving, B. & Skavberg Roaldsen, K. Intraclass correlation - A discussion and demonstration of basic features. PLoS One 14, e0219854. https://doi.org/10.1371/journal.pone.0219854 (2019). (PMID: 10.1371/journal.pone.0219854313296156645485)
Koo, T. K. & Li, M. Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15, 155–163. https://doi.org/10.1016/j.jcm.2016.02.012 (2016). (PMID: 10.1016/j.jcm.2016.02.012273305204913118)
Williams, K. Healthcare net promoter score: Meaning, calculation and benchmark, https://surveysparrow.com/blog/net-promoter-score-healthcare/ (2024).
Thai-Van, H. et al. Online digital audiometry vs. conventional audiometry: A multi-centre comparative clinical study. Int. J. Audiol. 62, 362–367. https://doi.org/10.1080/14992027.2022.2052979 (2023). (PMID: 10.1080/14992027.2022.205297935337229)
Villavisanis, D. F., Berson, E. R., Lauer, A. M., Cosetti, M. K. & Schrode, K. M. Sex-based differences in hearing loss: Perspectives from non-clinical research to clinical outcomes. Otol. Neurotol. 41, 290–298. https://doi.org/10.1097/MAO.0000000000002507 (2020). (PMID: 10.1097/MAO.0000000000002507317899687012726)
Carhart, R. J., J.F. Preferred method for clinical determination of pure-tone thresholds. J. Speech Hear. Disord. 24, 330–345 (1959).
Natus Sensory. Madsen® Astera2 - Clinical Audiometer, https://natussensory.com/products/madsen-astera2/ (2026).
Occupational Health and Safety Administration. Shoebox audiometry, https://www.shoebox.md/content/uploads/OSHA-Hearing-Testing.pdf (2019).
Caldwell, A. R. Exploring equivalence testing with the updated TOSTER R package, https://doi.org/10.31234/osf.io/ty8de (2022).
Lakens, D. Equivalence tests: A practical primer for t tests, correlations, and meta-analyses. Soc. Psychol. Pers. Sci. 8, 355–362. https://doi.org/10.1177/1948550617697177 (2017). (PMID: 10.1177/1948550617697177)
Gamer M, L. J., Fellows I. Package‘irr’, https://www.r-project.org/ (2022).
Bates, D., Machler, M., Bolker, B. & Walker, S. Fitting linear mixed-effects models using lme4. J. Stat. Softw. 67, 1–48. https://doi.org/10.18637/jss.v067.i01 (2015). (PMID: 10.18637/jss.v067.i01)
NASA. NASA TLX: Task Load Index, https://humansystems.arc.nasa.gov/groups/tlx/ (2020).
Contributed Indexing: Keywords: Auditory sciences; Clinical trials; Remote audiometry; Remote data collection; Validated tools
Entry Date(s): Date Created: 20260612 Date Completed: 20260731 Latest Revision: 20260731
Update Code: 20260801
DOI: 10.1038/s41598-026-49550-8
PMID: 42286011
Βάση Δεδομένων: MEDLINE
Περιγραφή
ISSN:2045-2322
DOI:10.1038/s41598-026-49550-8