Academic Journal

Preoperative neck growth and size are associated with type 1a endoleak after endovascular aneurysm repair.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Preoperative neck growth and size are associated with type 1a endoleak after endovascular aneurysm repair.
Συγγραφείς: Braet DJ; Department of Surgery, University of Michigan, Ann Arbor, MI. Electronic address: djbraet@med.umich.edu., Carne P; Department of Surgery, University of Michigan, Ann Arbor, MI., Campello Jorge CA; Department of Radiology, University of Wisconsin, Madison, WI., Delbono L; Department of Surgery, University of Michigan, Ann Arbor, MI., Eliason J; Department of Surgery, University of Michigan, Ann Arbor, MI., Figueroa CA; Department of Surgery, University of Michigan, Ann Arbor, MI; Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI., Davis FM; Department of Surgery, University of Michigan, Ann Arbor, MI., Burris NS; Department of Radiology, University of Wisconsin, Madison, WI.
Πηγή: Journal of vascular surgery [J Vasc Surg] 2026 Oct; Vol. 84 (4), pp. 857-865.e3. Date of Electronic Publication: 2026 Jun 02.
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Elsevier Country of Publication: United States NLM ID: 8407742 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1097-6809 (Electronic) Linking ISSN: 07415214 NLM ISO Abbreviation: J Vasc Surg Subsets: MEDLINE
Imprint Name(s): Publication: <2008-> : New York, NY : Elsevier
Original Publication: St. Louis, Mo. : Mosby, [c1984-
Ιατρικοί όροι (MeSH): Endoleak*/etiology , Endoleak*/diagnostic imaging , Endovascular Aneurysm Repair*/adverse effects , Aortic Aneurysm, Abdominal*/surgery , Aortic Aneurysm, Abdominal*/diagnostic imaging , Aorta, Abdominal*/diagnostic imaging , Aorta, Abdominal*/surgery , Blood Vessel Prosthesis Implantation*/adverse effects , Endovascular Procedures*/adverse effects, Aortography/methods ; Humans ; Computed Tomography Angiography ; Aged ; Retrospective Studies ; Male ; Aged, 80 and over ; Female ; Risk Factors ; Predictive Value of Tests ; Treatment Outcome ; Time Factors ; Imaging, Three-Dimensional ; Blood Vessel Prosthesis ; Risk Assessment
Περίληψη: Background: Type 1a endoleak (T1a) is seen in up to 15% of endovascular aortic aneurysm repair (EVAR) within instructions for use (IFU). Involvement of neck by abdominal aortic aneurysm (AAA) pathology may increase the risk of T1a, although current methods based on diameter/volume, may miss slow/submaximal preoperative growth in the neck. Vascular deformation mapping (VDM) is an emerging method for quantifying aortic wall growth in three-dimensional (3D) with submillimeter accuracy. We sought to determine the association of pre-EVAR neck growth and size with T1a using VDM.
Methods: We identified patients with infrarenal AAA who underwent EVAR between 2010 and 2024. Patients were included if they had ≥2 preoperative computed tomography angiograms (CTAs) completed ≥6 months apart with the last CTA being ≤3 months of EVAR. Patients with noncontrast computed tomography scans, off-IFU, and those treated with prophylactic endoanchors were excluded. Patient sex and device type were collected. AAA neck diameters and volumes were measured from both preoperative CTAs using PRAEVAorta (Nurea) and changes over time were calculated. VDM, which involves a multistep deformable image registration, was used to quantify 3D growth (3D defined as degree of deformation in the direction normal/perpendicular to the aortic wall) and 3D size (defined by local centerline radius) of the aneurysm neck. Statistical shape modeling was used to compare mean 3D growth and 3D size of the neck and four neck segments (anterior, posterior, left lateral, and right lateral) between patients with and without T1a.
Results: The cohort included 97 patients (90.7% male; average age, 73.0 ± 9.6 years). Twenty-one patients (21.6%) developed T1a. T1a endoleak was not associated with patient demographics, neck diameter, neck length, neck volume, or changes in neck diameter and/or volume (P > .05, for all). However, patients with T1a had larger 3D growth in the aneurysm neck (3.3 ± 0.8 vs 2.4 ± 0.6 mm/year; P < .001) and across all neck segments (P < .001, for all). Receiver-operating characteristic analysis identified a mean neck 3D growth ≥2.7 mm/year as a predictor of T1a (area under the curve, 0.78; sensitivity, 0.81; specificity, 0.76). Neck 3D size was larger in T1a patients compared with controls (12.5 ± 0.4 vs 11.5 ± 0.6 mm; P < .001) and across all neck segments (P < .001, for all). Receiver-operating characteristic analysis identified an optimal cut-point for neck 3D size of 11.9 mm as a predictor of T1a (area under the curve, 0.85; sensitivity, 86%; specificity, 84%).
Conclusions: Preoperative 3D growth and 3D size of the aneurysm neck are strong predictors of T1a, despite devices being on-IFU. VDM can provide important information about aneurysm growth that is not captured via current standard methods. Preoperative aneurysm neck growth/size should be considered for optimal EVAR planning.
(Copyright © 2026 The Author(s). Published by Elsevier Inc. All rights reserved.)
Competing Interests: Disclosures None.
Contributed Indexing: Keywords: Aneurysm growth; Aneurysm neck; Type 1a endoleak; Vascular deformation mapping
Entry Date(s): Date Created: 20260603 Date Completed: 20260909 Latest Revision: 20260909
Update Code: 20260910
DOI: 10.1016/j.jvs.2026.05.034
PMID: 42235840
Βάση Δεδομένων: MEDLINE
Περιγραφή
ISSN:1097-6809
DOI:10.1016/j.jvs.2026.05.034