Academic Journal
Agreement of Corvis ST Biomechanical IOP Measurements With Pachymetry-Based Correction Formulas in Patients With Keratoconus: A Comparative Analysis According to Disease Severity.
| Τίτλος: | Agreement of Corvis ST Biomechanical IOP Measurements With Pachymetry-Based Correction Formulas in Patients With Keratoconus: A Comparative Analysis According to Disease Severity. |
|---|---|
| Συγγραφείς: | Aydın FO; Department of Ophthalmology (F.O.A., Y.B.A., İ.Ç.A., S.E., B.K.Y.), University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey; and Department of Ophthalmology (A.C.), Akdeniz University, Antalya, Turkey., Ceylan A, Akbaş YB, Çelen Arabacı İ, Ermiş S, Kepez Yıldız B |
| Πηγή: | Eye & contact lens [Eye Contact Lens] 2026 Sep 01; Vol. 52 (9), pp. 362-367. Date of Electronic Publication: 2026 May 18. |
| Τύπος έκδοσης: | Journal Article; Comparative Study |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: Lippincott Williams & Wilkins Country of Publication: United States NLM ID: 101160941 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1542-233X (Electronic) Linking ISSN: 15422321 NLM ISO Abbreviation: Eye Contact Lens Subsets: MEDLINE |
| Imprint Name(s): | Original Publication: Hagerstown, Md. : Lippincott Williams & Wilkins, c2003- |
| Ιατρικοί όροι (MeSH): | Keratoconus*/physiopathology , Keratoconus*/diagnosis , Intraocular Pressure*/physiology , Tonometry, Ocular*/methods , Tonometry, Ocular*/instrumentation , Corneal Pachymetry*/methods , Cornea*/physiopathology, Humans ; Male ; Adult ; Prospective Studies ; Female ; Cross-Sectional Studies ; Severity of Illness Index ; Corneal Topography ; Young Adult ; Biomechanical Phenomena ; Adolescent |
| Περίληψη: | Objectives: To evaluate the agreement of intraocular pressure (IOP) measurements obtained by Corvis ST using biomechanically corrected IOP (bIOP), noncontact tonometry (NCT), and pachymetry-based correction formulas (Ehlers, Shah, Dresden, Spoerl) across different keratoconus severity levels and in comparison with healthy control eyes. Methods: This prospective, cross-sectional study included 77 patients with keratoconus (77 eyes), categorized by severity using Pentacam-based Topographic Keratoconus Classification and 54 healthy control patients. Patients underwent corneal tomography, and IOP was measured with Corvis ST. Uncorrected NCT-IOP (IOPnct), biomechanically corrected IOP (bIOP), and pachymetry-based corrected IOP (Ehlers, Shah, Dresden, Spoerl) were compared. Agreement among methods was assessed using Bland-Altman analysis. Results: The mean patient age was 26.4±7.3 years (59.7% male). NCT consistently underestimated IOP compared with bIOP, while Ehlers (+2.6 mm Hg), Shah (+1.4 mm Hg), and Dresden (+0.7 mm Hg) formulas significantly overestimated ( P <0.001). The Spoerl formula (-0.9 mm Hg) showed no significant difference compared with bIOP ( P =0.209). Bland-Altman analysis confirmed that the Spoerl formula had the smallest bias and narrowest limits of agreement across all keratoconus stages. Differences between methods became more pronounced with increasing severity, particularly evident for Ehlers and Shah formulas. In healthy control eyes, the different IOP estimation methods showed relatively small bias relative to bIOP. Conclusions: Noncontact tonometry significantly underestimates, and common pachymetry-based corrections (Ehlers, Shah, Dresden) tend to overestimate IOP in keratoconic eyes. The Spoerl formula provides IOP values most closely aligned with the Corvis ST bIOP across all keratoconus stages and was the most consistent pachymetric correction method relative to this biomechanically corrected comparator. Agreement between methods was closer in healthy corneas than in keratoconic eyes, supporting the influence of altered corneal biomechanics on tonometric measurements. (Copyright © 2026 Contact Lens Association of Ophthalmologists.) |
| Competing Interests: | The authors have no funding or conflicts of interest to disclose. |
| References: | Rabinowitz YS. Keratoconus. Surv Ophthalmol 1998;42:297–319. Hagishima M, Kamiya K, Fujimura F, et al. Effect of corneal astigmatism on intraocular pressure measurement using ocular response analyzer and Goldmann applanation tonometer. Graefe's Archive Clin Exp Ophthalmol 2010;248:257–262. Firat PG, Orman G, Doganay S, et al. Influence of corneal parameters in keratoconus on IOP readings obtained with different tonometers. Clin Exp Optom 2013;96:233–237. Tian L, Wang D, Wu Y, et al. Corneal biomechanical characteristics measured by the CorVis scheimpflug technology in eyes with primary open‐angle glaucoma and normal eyes. Acta Ophthalmol (Copenh) 2016;94:e317–e324. Matsuura M, Hirasawa K, Murata H, et al. The usefulness of CorvisST tonometry and the ocular response analyzer to assess the progression of glaucoma. Sci Rep 2017;7:40798. Clement CI, Parker DG, Goldberg I. Intra-ocular pressure measurement in a patient with a thin, thick or abnormal cornea. Open Ophthalmol J 2016;10:35–43. Mendez-Hernandez C, Arribas-Pardo P, Cuina-Sardina R, et al. Measuring intraocular pressure in patients with keratoconus with and without intrastromal corneal ring segments. J Glaucoma 2017;26:71–76. Sedaghat MR, Momeni-Moghaddam H, Roberts CJ, et al. Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces. Sci Rep 2021;11:11971. Tian L, Zhang H, Guo LL, et al. Distribution of corneal geometric landmarks and relationship between their distances and biomechanical parameters in the development of keratoconus. Front Bioeng Biotechnol 2021;9:766163. Flockerzi E, Häfner L, Xanthopoulou K, et al. Reliability analysis of successive corneal visualization scheimpflug technology measurements in different keratoconus stages. Acta Ophthalmol (Copenh) 2022;100:e83–e90. Matsuura M, Murata H, Fujino Y, et al. Relationship between novel intraocular pressure measurement from corvis ST and central corneal thickness and corneal hysteresis. Br J Ophthalmol 2020;104:563–568. Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenh) 1975;53:34–43. Shah S, Chatterjee A, Mathai M, et al. Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. Ophthalmology 1999;106:2154–2160. Kohlhaas M, Boehm AG, Spoerl E, et al. Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol 2006;124:471–476. Eliasy A, Chen K-J, Vinciguerra R, et al. Ex-vivo experimental validation of biomechanically-corrected intraocular pressure measurements on human eyes using the CorVis ST. Exp Eye Res 2018;175:98–102. de Padua Soares Bezerra B, Chan E, Chakrabarti R, et al. Intraocular pressure measurement after corneal transplantation. Surv Ophthalmol 2019;64:639–646. Halkiadakis I, Tzimis V, Gryparis A, et al. Evaluation of corvis ST tonometer with the updated software in glaucoma practice. Int J Ophthalmol 2022;15:438–445. Knauf D, Seitz B, Schießl G, et al. Analysis of various modalities for intraocular pressure measurement in relation to keratoconus severity in 246 eyes of the Homburg Keratoconus Center. Cornea 2023;42:829–836. Ramm L, Herber R, Spoerl E, et al. Intraocular pressure measurement using ocular response analyzer, dynamic contour tonometer, and scheimpflug analyzer corvis ST. J Ophthalmol 2019;2019:3879651. De Moraes CGV, Prata TS, Liebmann J, et al. Modalities of tonometry and their accuracy with respect to corneal thickness and irregularities. J Optom 2008;1:43–49. Alvani A, Hashemi H, Pakravan M, et al. Correction methods for noncontact intraocular pressure measurement in patients with keratoconus and healthy individuals. Arq Bras Oftalmol 2022;85:490–497. Chen Y, Rong H, Liu W, et al. Agreement of corrected intraocular pressure values between corvis ST and pentacam in patients with keratoconus, subclinical keratoconus, and normal cornea. Cornea 2021;40:1426–1432. Lee H, Roberts CJ, Kim TI, et al. Changes in biomechanically corrected intraocular pressure and dynamic corneal response parameters before and after transepithelial photorefractive keratectomy and femtosecond laser–assisted laser in situ keratomileusis. J Cataract Refract Surg 2017;43:1495–1503. Kohlhaas M, Spoerl E, Boehm AG, et al. A Correction Formula for the Real Intraocular Pressure After LASIK for the Correction of Myopic Astigmatism. Incorporated Thorofare, NJ: Slack, 2006; 263–267. De Bernardo M, Cembalo G, Rosa N. Reliability of intraocular pressure measurement by Goldmann applanation tonometry after refractive surgery: a review of different correction formulas. Clin Ophthalmol, 2020;14:2783–2788. Yang Z, Miao N, Wang L, et al. Comparison of different correction formulas and measurement methods for the accurate determination of intraocular pressure after SMILE and FS-LASIK surgery. BMC Ophthalmol 2022;22:404. Nakao Y, Kiuchi Y, Okumichi H. Evaluation of biomechanically corrected intraocular pressure using corvis ST and comparison of the corvis ST, noncontact tonometer, and Goldmann applanation tonometer in patients with glaucoma. PLoS One 2020;15:e0238395. |
| Contributed Indexing: | Keywords: Corvis ST; IOP correction formulas; Keratoconus; bIOP |
| Entry Date(s): | Date Created: 20260518 Date Completed: 20260821 Latest Revision: 20260928 |
| Update Code: | 20260928 |
| DOI: | 10.1097/ICL.0000000000001284 |
| PMID: | 42144724 |
| Βάση Δεδομένων: | MEDLINE |
| ISSN: | 1542-233X |
|---|---|
| DOI: | 10.1097/ICL.0000000000001284 |