The Efficacy and Safety of Synchronous Parallel Ultrasound for the Clinical Improvement of Cellulite Using High-Density Handpiece.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: The Efficacy and Safety of Synchronous Parallel Ultrasound for the Clinical Improvement of Cellulite Using High-Density Handpiece.
Συγγραφείς: Gold MH; Tennessee Clinical Research Center, Nashville, Tennessee, USA., Bernstein EF; Main Line Center for Laser Surgery, Ardmore, Pennsylvania, USA., Chapas AM; UnionDerm, New York, New York, USA.; Department of Dermatology, Icahn School of Medicine at Mt. Sinai, New York, New York, USA., Kilmer SL; Laser & Skin Surgery Center of Northern California, Sacramento, California, USA., Bedich O; SofWave Medical, Yokneam Illit, Israel., Amir R; SofWave Medical, Yokneam Illit, Israel., Goldberg DJ; Department of Dermatology, Icahn School of Medicine at Mt. Sinai, New York, New York, USA.; Cosmetic Dermatology and Clinical Research, Schweiger Dermatology Group, New York, New York, USA.
Πηγή: Journal of cosmetic dermatology [J Cosmet Dermatol] 2025 Dec; Vol. 24 (12), pp. e70597.
Τύπος έκδοσης: Clinical Trial; Journal Article; Multicenter Study
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Blackwell Science Country of Publication: England NLM ID: 101130964 Publication Model: Print Cited Medium: Internet ISSN: 1473-2165 (Electronic) Linking ISSN: 14732130 NLM ISO Abbreviation: J Cosmet Dermatol Subsets: MEDLINE
Imprint Name(s): Original Publication: Oxford, UK : Blackwell Science, c2002-
Ιατρικοί όροι (MeSH): Cellulite*/therapy , Cosmetic Techniques*/instrumentation , Cosmetic Techniques*/adverse effects , Ultrasonic Therapy*/instrumentation , Ultrasonic Therapy*/adverse effects , Ultrasonic Therapy*/methods, Adult ; Aged ; Female ; Humans ; Male ; Middle Aged ; Young Adult ; Buttocks ; Esthetics ; Follow-Up Studies ; Patient Satisfaction ; Prospective Studies ; Thigh ; Treatment Outcome
Περίληψη: Background: Cellulite is a common aesthetic condition of the skin, predominantly affecting more than 90% of postpubertal females. Energy-based devices (EBDs) have demonstrated efficacy in treating a variety of dermatologic concerns. A controlled thermal injury to the dermis can stimulate remodeling of the extracellular matrix (ECM), leading to skin tightening, an effect that may improve the dimpled appearance of cellulite.
Objective: To assess the efficacy and safety of synchronous parallel ultrasound using a high-density handpiece for improving cellulite appearance.
Materials and Methods: Sixty subjects, aged 23-65, were enrolled in a prospective, open-label, non-randomized, multicenter study. Subjects underwent two treatment sessions using a novel ultrasonic system equipped with a new high-density handpiece, applied on either one side or both sides of the thighs and/or buttocks. The follow-up period extended up to 3 months after the second treatment. Clinical improvements were evaluated by three blinded physicians based on baseline and follow-up photographs, using the Cellulite Severity Scale (CSS), Global Aesthetic Improvement Scale (GAIS), and Laxity Scale (LS). Satisfaction questionnaires were completed by subjects. Treatment discomfort was rated immediately after treatment using the Numerical Scale Response (NSR).
Results: Sixty subjects, with a mean age of 47, were enrolled in the study. GAIS results showed improvement in 91% of the treated areas, CSS score improved by 69%, while LS score improved by 53%. Most subjects (73%) reported satisfaction. Mean pain score was 4.26 ± 2.33. No serious adverse events were reported.
Conclusion: The novel ultrasound system was found to be effective and safe for improving cellulite appearance.
(© 2025 Sofwave Medical Ltd. Journal of Cosmetic Dermatology published by Wiley Periodicals LLC.)
References: J Cosmet Dermatol. 2025 Apr;24(4):e70134. (PMID: 40132902)
Metabolism. 2001 Apr;50(4):425-35. (PMID: 11288037)
Obesity (Silver Spring). 2007 Aug;15(8):1933-43. (PMID: 17712110)
Dermatol Surg. 2024 Oct 1;50(10):922-925. (PMID: 38754134)
J Cosmet Dermatol. 2025 Dec;24(12):e70597. (PMID: 41397931)
J Cosmet Dermatol. 2024 Jan;23(1):117-123. (PMID: 38031530)
J Am Acad Orthop Surg. 2000 Sep-Oct;8(5):305-13. (PMID: 11029558)
Dermatol Surg. 2021 Dec 1;47(12):1585-1589. (PMID: 34417390)
Cancer Res. 1984 Oct;44(10 Suppl):4736s-4744s. (PMID: 6467228)
Dermatol Surg. 2024 Feb 1;50(2):165-170. (PMID: 38091485)
Am J Clin Dermatol. 2015 Aug;16(4):243-256. (PMID: 25940753)
Cell Stem Cell. 2022 Aug 4;29(8):1161-1180. (PMID: 35931028)
JAMA Dermatol. 2018 Oct 1;154(10):1167-1174. (PMID: 30140900)
Plast Reconstr Surg Glob Open. 2022 Apr 08;10(4):e4237. (PMID: 35415061)
Aesthet Surg J Open Forum. 2023 Jun 21;5:ojad050. (PMID: 37424836)
J Int Med Res. 2009 Sep-Oct;37(5):1528-42. (PMID: 19930861)
J Cosmet Dermatol. 2023 May;22(5):1488-1494. (PMID: 36757157)
Int J Womens Dermatol. 2018 Oct 22;5(1):68-72. (PMID: 30809581)
Dermatol Surg. 2020 Oct;46 Suppl 1:S77-S85. (PMID: 32976174)
Contributed Indexing: Keywords: Synchronous Ultrasound Parallel Beam Technology; cellulite; skin laxity
Entry Date(s): Date Created: 20251215 Date Completed: 20251215 Latest Revision: 20251218
Update Code: 20260130
PubMed Central ID: PMC12705495
DOI: 10.1111/jocd.70597
PMID: 41397931
Βάση Δεδομένων: MEDLINE
Περιγραφή
ISSN:1473-2165
DOI:10.1111/jocd.70597