Academic Journal
Influence of Image Processing on Radiomic Features From Magnetic Resonance Imaging.
| Τίτλος: | Influence of Image Processing on Radiomic Features From Magnetic Resonance Imaging. |
|---|---|
| Συγγραφείς: | Wichtmann BD; From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany., Harder FN; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany., Weiss K; Philips GmbH, Hamburg, Germany., Schönberg SO; Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Germany., Attenberger UI; From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany., Alkadhi H; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Switzerland., Pinto Dos Santos D, Baeßler B |
| Πηγή: | Investigative radiology [Invest Radiol] 2023 Mar 01; Vol. 58 (3), pp. 199-208. Date of Electronic Publication: 2022 Sep 06. |
| Τύπος έκδοσης: | Journal Article; Research Support, Non-U.S. Gov't |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: Lippincott Williams & Wilkins Country of Publication: United States NLM ID: 0045377 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1536-0210 (Electronic) Linking ISSN: 00209996 NLM ISO Abbreviation: Invest Radiol Subsets: MEDLINE |
| Imprint Name(s): | Publication: 1998- : Hagerstown, MD : Lippincott Williams & Wilkins Original Publication: Philadelphia. |
| Ιατρικοί όροι (MeSH): | Image Processing, Computer-Assisted*/methods , Magnetic Resonance Imaging*, Reproducibility of Results ; Phantoms, Imaging |
| Περίληψη: | Objective: Before implementing radiomics in routine clinical practice, comprehensive knowledge about the repeatability and reproducibility of radiomic features is required. The aim of this study was to systematically investigate the influence of image processing parameters on radiomic features from magnetic resonance imaging (MRI) in terms of feature values as well as test-retest repeatability. Materials and Methods: Utilizing a phantom consisting of 4 onions, 4 limes, 4 kiwifruits, and 4 apples, we acquired a test-retest dataset featuring 3 of the most commonly used MRI sequences on a 3 T scanner, namely, a T1-weighted, a T2-weighted, and a fluid-attenuated inversion recovery sequence, each at high and low resolution. After semiautomatic image segmentation, image processing with systematic variation of image processing parameters was performed, including spatial resampling, intensity discretization, and intensity rescaling. For each respective image processing setting, a total of 45 radiomic features were extracted, corresponding to the following 7 matrices/feature classes: conventional indices, histogram matrix, shape matrix, gray-level zone length matrix, gray-level run length matrix, neighboring gray-level dependence matrix, and gray-level cooccurrence matrix. Systematic differences of individual features between different resampling steps were assessed using 1-way analysis of variance with Tukey-type post hoc comparisons to adjust for multiple testing. Test-retest repeatability of radiomic features was measured using the concordance correlation coefficient, dynamic range, and intraclass correlation coefficient. Results: Image processing influenced radiological feature values. Regardless of the acquired sequence and feature class, significant differences ( P < 0.05) in feature values were found when the size of the resampled voxels was too large, that is, bigger than 3 mm. Almost all higher-order features depended strongly on intensity discretization. The effects of intensity rescaling were negligible except for some features derived from T1-weighted sequences. For all sequences, the percentage of repeatable features (concordance correlation coefficient and dynamic range ≥ 0.9) varied considerably depending on the image processing settings. The optimal image processing setting to achieve the highest percentage of stable features varied per sequence. Irrespective of image processing, the fluid-attenuated inversion recovery sequence in high-resolution overall yielded the highest number of stable features in comparison with the other sequences (89% vs 64%-78% for the respective optimal image processing settings). Across all sequences, the most repeatable features were generally obtained for a spatial resampling close to the originally acquired voxel size and an intensity discretization to at least 32 bins. Conclusion: Variation of image processing parameters has a significant impact on the values of radiomic features as well as their repeatability. Furthermore, the optimal image processing parameters differ for each MRI sequence. Therefore, it is recommended that these processing parameters be determined in corresponding test-retest scans before clinical application. Extensive repeatability, reproducibility, and validation studies as well as standardization are required before quantitative image analysis and radiomics can be reliably translated into routine clinical care. (Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.) |
| Competing Interests: | Conflicts of interest and sources of funding: The authors received funding from Deutsche Forschungsgemeinschaft/German Research Foundation (DFG) through grant 428149221. Wichtmann has given scientific presentations for Philips GmbH and the Bender group/b.e.imaging GmbH on unrelated topics for which monetary compensation was received. In addition, Weiss is working for Philips GmbH. |
| References: | Obermeyer Z, Emanuel EJ. Predicting the future—big data, machine learning, and clinical medicine. N Engl J Med . 2016;375:1216–1219. Lambin P, Leijenaar RTH, Deist TM, et al. Radiomics: the bridge between medical imaging and personalized medicine. Nat Rev Clin Oncol . 2017;14:749–762. Attenberger UI, Biber S, Wichtmann BD. Technological advances of magnetic resonance imaging in today's health care environment. Invest Radiol . 2020;55:531–542. Zwanenburg A, Vallieres M, Abdalah MA, et al. The Image Biomarker Standardization Initiative: standardized quantitative radiomics for high-throughput image-based phenotyping. Radiology . 2020;295:328–338. Hagiwara A, Fujita S, Ohno Y, et al. Variability and standardization of quantitative imaging: monoparametric to multiparametric quantification, radiomics, and artificial intelligence. Invest Radiol . 2020;55:601–616. van Timmeren JE, Cester D, Tanadini-Lang S, et al. Radiomics in medical imaging—“how-to” guide and critical reflection. Insights Imaging . 2020;11:91. Pinto Dos Santos D, Dietzel M, Baessler B. A decade of radiomics research: are images really data or just patterns in the noise? Eur Radiol . 2021;31:1–4. Muhlbauer J, Egen L, Kowalewski KF, et al. Radiomics in renal cell carcinoma—a systematic review and meta-analysis. Cancers (Basel) . 2021;13:1348. Ponsiglione A, Stanzione A, Cuocolo R, et al. Cardiac CT and MRI radiomics: systematic review of the literature and radiomics quality score assessment. Eur Radiol . 2022;32:2629–2638. Zwanenburg A, Leger S, Vallières M, Löck S. Image biomarker standardisation initiative. arXiv. 2016. Preprint arXiv:1612.07003. Mackin D, Fave X, Zhang L, et al. Measuring computed tomography scanner variability of radiomics features. Invest Radiol . 2015;50:757–765. Peng X, Yang S, Zhou L, et al. Repeatability and reproducibility of computed tomography Radiomics for pulmonary nodules: a multicenter phantom study. Invest Radiol . 2022;57:242–253. Euler A, Laqua FC, Cester D, et al. Virtual monoenergetic images of dual-energy CT-impact on repeatability, reproducibility, and classification in radiomics. Cancers (Basel) . 2021;13:4710. Lee SB, Cho YJ, Hong Y, et al. Deep learning-based image conversion improves the reproducibility of computed tomography radiomics features: a phantom study. Invest Radiol . 2022;57:308–317. Mayerhoefer ME, Szomolanyi P, Jirak D, et al. Effects of magnetic resonance image interpolation on the results of texture-based pattern classification: a phantom study. Invest Radiol . 2009;44:405–411. Park JE, Kim HS. Radiomics as a quantitative imaging biomarker: practical considerations and the current standpoint in neuro-oncologic studies. Nucl Med Mol Imaging . 2018;52:99–108. Collewet G, Strzelecki M, Mariette F. Influence of MRI acquisition protocols and image intensity normalization methods on texture classification. Magn Reson Imaging . 2004;22:81–91. Saha A, Harowicz MR, Mazurowski MA. Breast cancer MRI radiomics: an overview of algorithmic features and impact of inter-reader variability in annotating tumors. Med Phys . 2018;45:3076–3085. Cattell R, Chen S, Huang C. Robustness of radiomic features in magnetic resonance imaging: review and a phantom study. Vis Comput Ind Biomed Art . 2019;2:19. Baessler B, Weiss K, Pinto Dos Santos D. Robustness and reproducibility of radiomics in magnetic resonance imaging: a phantom study. Invest Radiol . 2019;54:221–228. Yip SS, Aerts HJ. Applications and limitations of radiomics. Phys Med Biol . 2016;61:R150–R166. Peerlings J, Woodruff HC, Winfield JM, et al. Stability of radiomics features in apparent diffusion coefficient maps from a multi-Centre test-retest trial. Sci Rep . 2019;9:4800. Schwier M, van Griethuysen J, Vangel MG, et al. Repeatability of multiparametric prostate MRI Radiomics features. Sci Rep . 2019;9:9441. Traverso A, Kazmierski M, Shi Z, et al. Stability of radiomic features of apparent diffusion coefficient (ADC) maps for locally advanced rectal cancer in response to image pre-processing. Phys Med . 2019;61:44–51. Mueller-Lisse UG, Murer S, Mueller-Lisse UL, et al. Everyman's prostate phantom: kiwi-fruit substitute for human prostates at magnetic resonance imaging, diffusion-weighted imaging and magnetic resonance spectroscopy. Eur Radiol . 2017;27:3362–3371. Fedorov A, Beichel R, Kalpathy-Cramer J, et al. 3D slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging . 2012;30:1323–1341. Nioche C, Orlhac F, Boughdad S, et al. LIFEx: a freeware for radiomic feature calculation in multimodality imaging to accelerate advances in the characterization of tumor heterogeneity. Cancer Res . 2018;78:4786–4789. R: A Language and Environment for Statistical Computing. Version 3.4.0 [computer program] . Vienna, Austria: R Foundation for Statistical Computing; 2017. RStudio: Integrated Development for R. Version 1.0.136 [computer program] . Boston, MA; 2016. Available at: http://www.rstudio.com/ . Accessed August 27, 2022. DescTools: Tools for Descriptive Statistic. Version 0.99.24 [computer program]. 2018. psych: Procedure for Psychological, Psychometric, and Personality Research. Version 1.7.8 [computer program] . Evanston, IL: Northwestern University; 2017. ggplot2: Elegant Graphics for Data Analysis [computer program] . New York, NY: Springer-Verlag; 2009. Liaw A, Wiener M. Classification and regression by randomForest. R News . 2002;2:18–22. Epi: A Package for Statistical Analysis in Epidemiology. Version 2.12 [computer program] . 2017. Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics . 1989;45:255–268. Balagurunathan Y, Kumar V, Gu Y, et al. Test-retest reproducibility analysis of lung CT image features. J Digit Imaging . 2014;27:805–823. Schuster DP. The opportunities and challenges of developing imaging biomarkers to study lung function and disease. Am J Respir Crit Care Med . 2007;176:224–230. Akoglu H. User's guide to correlation coefficients. Turk J Emerg Med . 2018;18:91–93. Gillies RJ, Kinahan PE, Hricak H. Radiomics: images are more than pictures, they are data. Radiology . 2016;278:563–577. Fiset S, Welch ML, Weiss J, et al. Repeatability and reproducibility of MRI-based radiomic features in cervical cancer. Radiother Oncol . 2019;135:107–114. Yan J, Chu-Shern JL, Loi HY, et al. Impact of image reconstruction settings on texture features in 18F-FDG PET. J Nucl Med . 2015;56:1667–1673. Shafiq-Ul-Hassan M, Zhang GG, Latifi K, et al. Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels. Med Phys . 2017;44:1050–1062. Vallieres M, Freeman CR, Skamene SR, et al. A radiomics model from joint FDG-PET and MRI texture features for the prediction of lung metastases in soft-tissue sarcomas of the extremities. Phys Med Biol . 2015;60:5471–5496. Carre A, Klausner G, Edjlali M, et al. Standardization of brain MR images across machines and protocols: bridging the gap for MRI-based radiomics. Sci Rep . 2020;10:12340. Duron L, Balvay D, Vande Perre S, et al. Gray-level discretization impacts reproducible MRI radiomics texture features. PLoS One . 2019;14:e0213459. Yang F, Dogan N, Stoyanova R, et al. Evaluation of radiomic texture feature error due to MRI acquisition and reconstruction: a simulation study utilizing ground truth. Phys Med . 2018;50:26–36. Wennmann M, Thierjung H, Bauer F, et al. Repeatability and reproducibility of ADC measurements and MRI signal intensity measurements of bone marrow in monoclonal plasma cell disorders: a prospective bi-institutional multiscanner, multiprotocol study. Invest Radiol . 2022;57:272–281. Makowski MR, Bressem KK, Franz L, et al. De novo radiomics approach using image augmentation and features from T1 mapping to predict Gleason scores in prostate cancer. Invest Radiol . 2021;56:661–668. |
| Entry Date(s): | Date Created: 20220907 Date Completed: 20230214 Latest Revision: 20230926 |
| Update Code: | 20260130 |
| DOI: | 10.1097/RLI.0000000000000921 |
| PMID: | 36070524 |
| Βάση Δεδομένων: | MEDLINE |
| ISSN: | 1536-0210 |
|---|---|
| DOI: | 10.1097/RLI.0000000000000921 |