COMPARISON OF PHOTON-COUNTING AND FLAT-PANEL DIGITAL MAMMMOGRAPHY FOR THE PURPOSE OF 3D IMAGING USING A NOVEL IMAGE PROCESSING METHOD.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: COMPARISON OF PHOTON-COUNTING AND FLAT-PANEL DIGITAL MAMMMOGRAPHY FOR THE PURPOSE OF 3D IMAGING USING A NOVEL IMAGE PROCESSING METHOD.
Συγγραφείς: Svahn TM; Centre for Research and Development, Uppsala University/Region Gävleborg, 801 88 Gävle, Sweden., Gordon R; Gulf Marine Specimen Laboratory, Panacea, FL 32346, USA.; C.S. Mott Center for Human Growth & Development, Department of Obstetrics & Gynecology, Wayne State University, Detroit, MI 48201, USA., Ast JC; Department of Organismal Biology, 752 36 Uppsala University, Uppsala, Sweden., Riffel J; Department of Clinical Radiology and Nuclear Medicine, 68167 Mannheim, University of Heidelberg, Germany., Hartbauer M; Institute of Biology, Universitätsplatz 2, University of Graz, 8010 Graz, Austria.
Πηγή: Radiation protection dosimetry [Radiat Prot Dosimetry] 2021 Oct 12; Vol. 195 (3-4), pp. 454-461.
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Oxford University Press Country of Publication: England NLM ID: 8109958 Publication Model: Print Cited Medium: Internet ISSN: 1742-3406 (Electronic) Linking ISSN: 01448420 NLM ISO Abbreviation: Radiat Prot Dosimetry Subsets: MEDLINE
Imprint Name(s): Publication: 2004- : Oxford, UK : Oxford University Press
Original Publication: Ashford, Kent : Nuclear Technology Pub., c1981-
Ιατρικοί όροι (MeSH): Image Processing, Computer-Assisted* , Imaging, Three-Dimensional*, Algorithms ; Phantoms, Imaging ; Photons ; Radiographic Image Enhancement
Περίληψη: The purpose of the present work was to compare the quality of low-dose projections from a photon-counting with a flat-panel system, and to evaluate a novel image processing method. Images were acquired of phantoms in both systems at average glandular doses ranging from ~ 0.15 to 1.4 mGy. Automated detection of low-contrast features and modulation transfer functions were evaluated in phantom images. The novel image processing method was compared with standard processing in a series of clinical cases. At low-doses (~0.15) the photon-counting system out-performed the flat-panel system with a much higher detectability of low-contrast features. The novel algorithm was superior to both manufacturers' processing in terms of conspicuity of soft-tissue lesions (p > 0.05), whereas it was not significantly different in calcification conspicuity. Photon-counting should allow more low-dose projections to be acquired at the same total dose. The novel image enhancer can help to further increase the image quality.