Academic Journal

Effect of Laryngeal Mask Airway Insertion on Intraocular Pressure Response: Systematic Review and Meta-Analysis.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Effect of Laryngeal Mask Airway Insertion on Intraocular Pressure Response: Systematic Review and Meta-Analysis.
Συγγραφείς: Obsa MS; School of Anesthesia, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Kanche ZZ; School of Pharmacy, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Olana Fite R; School of Nursing, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Tura TS; School of Nursing, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Adema BG; School of Nursing, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Kinfe AA; School of Nursing, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Kercho MW; School of Midwifery, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Paulos Chanko K; School of Midwifery, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Shanka GM; School of Medicine, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Lencha AA; School of Public Health, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Asnake Azeze G; School of Midwifery, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Hanfore LK; School of Nursing, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Adulo NA; School of Nursing, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Dessu BK; School of Anesthesia, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Wolde GD; School of Anesthesia, Wolaita Soddo University, Wolaita Soddo, Ethiopia., Workie SB; School of Public Health, Wolaita Soddo University, Wolaita Soddo, Ethiopia.
Πηγή: Anesthesiology research and practice [Anesthesiol Res Pract] 2020 Jul 09; Vol. 2020, pp. 7858434. Date of Electronic Publication: 2020 Jul 09 (Print Publication: 2020).
Τύπος έκδοσης: Journal Article; Review
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Wiley Country of Publication: United States NLM ID: 101532982 Publication Model: eCollection Cited Medium: Print ISSN: 1687-6962 (Print) Linking ISSN: 16876962 NLM ISO Abbreviation: Anesthesiol Res Pract Subsets: PubMed not MEDLINE
Imprint Name(s): Publication: 2023- : [Philadelphia, PA] : Wiley
Original Publication: New York, N.Y. : Hindawi Pub. Corp., 2008-
Περίληψη: Background: Use of laryngeal mask airway as an alternative to the endotracheal tube has attracted the attention of several workers with regard to intraocular pressure changes. However, the previous studies have reported different results while comparing intraocular pressure, following insertion of laryngeal mask airway or the endotracheal tube. Therefore, this systematic review and meta-analysis was aimed to generate the best possible evidence on the intraocular pressure response to endotracheal tube intubation and laryngeal mask airway insertion.
Methods: Electronic databases like PubMed, CINAHL, EMBASE, Google Scholar, Cochrane library databases, and Mednar were used. All original peer-reviewed papers which reported the mean and standard deviation of IOP before and after airway instrumentation in both groups were included. Two reviewers independently extracted the data using a standardized data extraction format for eligibility and appraised their quality. Data were analyzed using the STATA version 14 software. The pooled standard mean difference was estimated with the random-effect model. Heterogeneity between studies was assessed by the I 2 statistics test. A subgroup analysis was done to assess the source of variation between the studies.
Result: A total of 47 research papers were reviewed, of which, six studies were finally included in this systematic review and meta-analysis. The overall pooled standard mean difference of intraocular pressure was 1.30 (95% CI, 0.70, 1.90), showing that LMA insertion is better than ETT intubation to maintain stable intraocular pressure. A random-effect model was employed to estimate the pooled standard mean differences due to severe heterogeneity (I 2 79.45,  p ≤ 0.001).
Conclusion: The available information suggests that the LMA provides lesser intraocular pressure response in comparison with the conventional tracheal tube.
(Copyright © 2020 Mohammed Suleiman Obsa et al.)
Competing Interests: The authors declare that they have no conflicts of interest.
References: Anaesthesia. 1991 Nov;46(11):922-4. (PMID: 1750590)
J Clin Anesth. 1991 Jul-Aug;3(4):310-3. (PMID: 1910800)
Am J Ophthalmol. 2007 Oct;144(4):507-10. (PMID: 17686451)
J Clin Anesth. 2001 Jun;13(4):264-7. (PMID: 11435050)
Anaesth Intensive Care. 2008 May;36(3):431-5. (PMID: 18564806)
Anesthesiology. 1996 Mar;84(3):686-99. (PMID: 8659797)
Br J Anaesth. 1992 Aug;69(2):143-7. (PMID: 1309179)
Can J Anaesth. 2003 Aug-Sep;50(7):732-46. (PMID: 12944451)
Ann Intern Med. 2009 Aug 18;151(4):264-9, W64. (PMID: 19622511)
Acta Anaesthesiol Scand. 1999 Mar;43(3):343-6. (PMID: 10081543)
Br J Anaesth. 1998 Jan;80(1):106-22; discussion 104-5. (PMID: 9505789)
Anesthesiology. 1977 Dec;47(6):524-5. (PMID: 337858)
Can Anaesth Soc J. 1960 Jan;7:39-43. (PMID: 13846283)
J Res Med Sci. 2012 Jun;17(6):503-7. (PMID: 23626623)
J Clin Anesth. 1999 May;11(3):216-9. (PMID: 10434217)
J Anaesthesiol Clin Pharmacol. 2012 Jul;28(3):326-9. (PMID: 22869938)
Anaesthesia. 1995 Feb;50(2):126-9. (PMID: 7710022)
BMC Med Res Methodol. 2008 Nov 27;8:79. (PMID: 19036172)
Br J Anaesth. 1987 Mar;59(3):295-9. (PMID: 3828177)
Anaesth Intensive Care. 2004 Jun;32(3):383-9. (PMID: 15264735)
J Postgrad Med. 2001 Jul-Sep;47(3):181-4. (PMID: 11832619)
Anaesthesia. 1997 Aug;52(8):794-6. (PMID: 9291769)
Entry Date(s): Date Created: 20200723 Latest Revision: 20220415
Update Code: 20260130
PubMed Central ID: PMC7368206
DOI: 10.1155/2020/7858434
PMID: 32695160
Βάση Δεδομένων: MEDLINE
Περιγραφή
ISSN:1687-6962
DOI:10.1155/2020/7858434