Performance evaluation of a fast neutron multiplicity counting system using liquid scintillation detectors: Geant4 simulation and experimental validation with252Cf.

Bibliographic Details
Title: Performance evaluation of a fast neutron multiplicity counting system using liquid scintillation detectors: Geant4 simulation and experimental validation with252Cf.
Authors: Cheng, Wei1,2 (AUTHOR), Jia, Wenbao1,2 (AUTHOR), Cheng, Can2,3 (AUTHOR), Zhang, Yan1,2 (AUTHOR), Li, Duohong4 (AUTHOR), Li, Da4 (AUTHOR), Xu, Jiahao5 (AUTHOR), Shan, Qing1,2 (AUTHOR) shanqing@nuaa.edu.cn
Source: Journal of Radioanalytical & Nuclear Chemistry. Sep2026, p1-7. 7p.
Subject Terms: *Neutron multiplicity, *Monte Carlo method, *Scintillation counters, *Radioactive substances
Abstract: \nHighlights: Accurate and rapid non-destructive assay of nuclear materials is critical for nuclear safeguards and arms control. To overcome the limitations of conventional thermal neutron multiplicity counting—such as long measurement times and high susceptibility to accidental coincidences—we developed and validated a fast neutron multiplicity counting (FNMC) system. Our system employs six EJ-301 organic liquid scintillation detectors, leveraging their excellent pulse-shape discrimination and fast timing capabilities. We established a comprehensive Geant4 Monte Carlo model to simulate the system’s response and systematically evaluated different time-correlation analysis methods. The Multiplicity Shift Register (MSR) technique, with an optimized 60 ns coincidence gate, was found to exhibit superior performance, enabling a simulated mass determination accuracy of 0.4% for a 1 μg 252Cf source. Experimental measurements of a 252Cf source demonstrated the system’s practical viability, achieving a mass error of 7.33%. The primary sources of discrepancy between simulation and experiment were identified as imperfect neutron-gamma discrimination and inter-detector neutron cross-talk, which provide clear directions for subsequent system optimization.A six-detector FNMC system was validated for rapid 252Cf assay.Geant4 simulations identified MSR with a 60 ns gate as the most accurate method.Neutron-gamma discrimination and cross-talk were the main limits on measurement accuracy.A six-detector FNMC system was validated for rapid 252Cf assay.Geant4 simulations identified MSR with a 60 ns gate as the most accurate method.Neutron-gamma discrimination and cross-talk were the main limits on measurement accuracy. [ABSTRACT FROM AUTHOR]
Database: Academic Search Index
FullText Links:
  – Type: other
Text:
  Availability: 0
CustomLinks:
  – Url: https://dx.doi.org/doi:10.1007/s10967-026-11179-2
    Name: EDS - Springer Nature Journals (s7799221)
    Category: fullText
    Text: View record at Springer
Header DbId: asx
DbLabel: Academic Search Index
An: 197463333
RelevancyScore: 1452
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 1452.42822265625
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Performance evaluation of a fast neutron multiplicity counting system using liquid scintillation detectors: Geant4 simulation and experimental validation with252Cf.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Cheng%2C+Wei%22">Cheng, Wei</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Jia%2C+Wenbao%22">Jia, Wenbao</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Cheng%2C+Can%22">Cheng, Can</searchLink><relatesTo>2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhang%2C+Yan%22">Zhang, Yan</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Li%2C+Duohong%22">Li, Duohong</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Li%2C+Da%22">Li, Da</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Xu%2C+Jiahao%22">Xu, Jiahao</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shan%2C+Qing%22">Shan, Qing</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> shanqing@nuaa.edu.cn</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Radioanalytical+%26+Nuclear+Chemistry%22">Journal of Radioanalytical & Nuclear Chemistry</searchLink>. Sep2026, p1-7. 7p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Neutron+multiplicity%22">Neutron multiplicity</searchLink><br />*<searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink><br />*<searchLink fieldCode="DE" term="%22Scintillation+counters%22">Scintillation counters</searchLink><br />*<searchLink fieldCode="DE" term="%22Radioactive+substances%22">Radioactive substances</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: \nHighlights: Accurate and rapid non-destructive assay of nuclear materials is critical for nuclear safeguards and arms control. To overcome the limitations of conventional thermal neutron multiplicity counting—such as long measurement times and high susceptibility to accidental coincidences—we developed and validated a fast neutron multiplicity counting (FNMC) system. Our system employs six EJ-301 organic liquid scintillation detectors, leveraging their excellent pulse-shape discrimination and fast timing capabilities. We established a comprehensive Geant4 Monte Carlo model to simulate the system’s response and systematically evaluated different time-correlation analysis methods. The Multiplicity Shift Register (MSR) technique, with an optimized 60 ns coincidence gate, was found to exhibit superior performance, enabling a simulated mass determination accuracy of 0.4% for a 1 μg 252Cf source. Experimental measurements of a 252Cf source demonstrated the system’s practical viability, achieving a mass error of 7.33%. The primary sources of discrepancy between simulation and experiment were identified as imperfect neutron-gamma discrimination and inter-detector neutron cross-talk, which provide clear directions for subsequent system optimization.A six-detector FNMC system was validated for rapid 252Cf assay.Geant4 simulations identified MSR with a 60 ns gate as the most accurate method.Neutron-gamma discrimination and cross-talk were the main limits on measurement accuracy.A six-detector FNMC system was validated for rapid 252Cf assay.Geant4 simulations identified MSR with a 60 ns gate as the most accurate method.Neutron-gamma discrimination and cross-talk were the main limits on measurement accuracy. [ABSTRACT FROM AUTHOR]
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=asx&AN=197463333
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10967-026-11179-2
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 1
    Subjects:
      – SubjectFull: Neutron multiplicity
        Type: general
      – SubjectFull: Monte Carlo method
        Type: general
      – SubjectFull: Scintillation counters
        Type: general
      – SubjectFull: Radioactive substances
        Type: general
    Titles:
      – TitleFull: Performance evaluation of a fast neutron multiplicity counting system using liquid scintillation detectors: Geant4 simulation and experimental validation with252Cf.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Cheng, Wei
      – PersonEntity:
          Name:
            NameFull: Jia, Wenbao
      – PersonEntity:
          Name:
            NameFull: Cheng, Can
      – PersonEntity:
          Name:
            NameFull: Zhang, Yan
      – PersonEntity:
          Name:
            NameFull: Li, Duohong
      – PersonEntity:
          Name:
            NameFull: Li, Da
      – PersonEntity:
          Name:
            NameFull: Xu, Jiahao
      – PersonEntity:
          Name:
            NameFull: Shan, Qing
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 30
              M: 09
              Text: Sep2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 02365731
          Titles:
            – TitleFull: Journal of Radioanalytical & Nuclear Chemistry
              Type: main
ResultId 1