Academic Journal
Addressing Analytical Challenges to Improve Laboratory Consistency in Unbound Flucloxacillin Measurement
| Τίτλος: | Addressing Analytical Challenges to Improve Laboratory Consistency in Unbound Flucloxacillin Measurement |
|---|---|
| Συγγραφείς: | Van herteryck, Cathérine, Reyns, Tim, Jager, Nynke, Stove, Veronique, Verougstraete, Nick |
| Πηγή: | Therapeutic Drug Monitoring ; ISSN 0163-4356 1536-3694 |
| Στοιχεία εκδότη: | Ovid Technologies (Wolters Kluwer Health) |
| Έτος έκδοσης: | 2026 |
| Περιγραφή: | Background: Accurate quantification of flucloxacillin (FLU) in plasma is essential for therapeutic drug monitoring (TDM). Although TDM of FLU traditionally targets total concentrations, only the unbound drug is pharmacologically active. Ultrafiltration (UF) enables the separation of the unbound drug; however, multiple pre-analytical variables can affect results. Furthermore, the lack of standardized protocols currently limits interlaboratory reproducibility. This study aims to develop and validate a robust liquid chromatography-high-resolution mass spectrometric (LC-HRMS) method for quantifying unbound FLU, including an extensive assessment of analyte stability. Cross-validation with an external laboratory was performed to support harmonization of UF protocols. Methods: Ultrafiltrate was obtained after incubation (10 minutes at 37°C) and UF (30 minutes at 1900 g and 37°C), and analyzed using LC-HRMS. Analytical and pre-analytical protocols were validated in accordance with European Medicine Agency guidelines, evaluating calibration curves, selectivity, carryover, accuracy, precision, matrix effect, stability, dilution integrity, as well as nonspecific binding, and membrane protein leakage. Cross-validation was conducted using patient samples from clinical routine. Results: The method validation was successful. Ultrafiltrate stability was substantially lower than plasma stability, emphasizing the need for immediate postfiltration analysis. Interlaboratory comparison demonstrated strong concordance, with >90% of samples differing by <±25.0%. Conclusions: A validated LC-HRMS method for quantifying unbound FLU was developed using UF. Cross-validation showed that comparable results can be achieved across laboratories when key UF parameters, such as device type and temperature, are harmonized. Because of the limited stability of FLU in ultrafiltrate, sample storage in plasma matrix is recommended. |
| Τύπος εγγράφου: | article in journal/newspaper |
| Γλώσσα: | English |
| DOI: | 10.1097/ftd.0000000000001449 |
| DOI: | 10.1097/FTD.0000000000001449 |
| Διαθεσιμότητα: | https://doi.org/10.1097/ftd.0000000000001449 https://journals.lww.com/10.1097/FTD.0000000000001449 |
| Αριθμός Καταχώρησης: | edsbas.F8FDBC94 |
| Βάση Δεδομένων: | BASE |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://doi.org/10.1097/ftd.0000000000001449# Name: EDS - BASE (ns324271) Category: fullText Text: View record from BASE |
|---|---|
| Header | DbId: edsbas DbLabel: BASE An: edsbas.F8FDBC94 RelevancyScore: 941 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 940.635681152344 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Addressing Analytical Challenges to Improve Laboratory Consistency in Unbound Flucloxacillin Measurement – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Van+herteryck%2C+Cathérine%22">Van herteryck, Cathérine</searchLink><br /><searchLink fieldCode="AR" term="%22Reyns%2C+Tim%22">Reyns, Tim</searchLink><br /><searchLink fieldCode="AR" term="%22Jager%2C+Nynke%22">Jager, Nynke</searchLink><br /><searchLink fieldCode="AR" term="%22Stove%2C+Veronique%22">Stove, Veronique</searchLink><br /><searchLink fieldCode="AR" term="%22Verougstraete%2C+Nick%22">Verougstraete, Nick</searchLink> – Name: TitleSource Label: Source Group: Src Data: Therapeutic Drug Monitoring ; ISSN 0163-4356 1536-3694 – Name: Publisher Label: Publisher Information Group: PubInfo Data: Ovid Technologies (Wolters Kluwer Health) – Name: DatePubCY Label: Publication Year Group: Date Data: 2026 – Name: Abstract Label: Description Group: Ab Data: Background: Accurate quantification of flucloxacillin (FLU) in plasma is essential for therapeutic drug monitoring (TDM). Although TDM of FLU traditionally targets total concentrations, only the unbound drug is pharmacologically active. Ultrafiltration (UF) enables the separation of the unbound drug; however, multiple pre-analytical variables can affect results. Furthermore, the lack of standardized protocols currently limits interlaboratory reproducibility. This study aims to develop and validate a robust liquid chromatography-high-resolution mass spectrometric (LC-HRMS) method for quantifying unbound FLU, including an extensive assessment of analyte stability. Cross-validation with an external laboratory was performed to support harmonization of UF protocols. Methods: Ultrafiltrate was obtained after incubation (10 minutes at 37°C) and UF (30 minutes at 1900 g and 37°C), and analyzed using LC-HRMS. Analytical and pre-analytical protocols were validated in accordance with European Medicine Agency guidelines, evaluating calibration curves, selectivity, carryover, accuracy, precision, matrix effect, stability, dilution integrity, as well as nonspecific binding, and membrane protein leakage. Cross-validation was conducted using patient samples from clinical routine. Results: The method validation was successful. Ultrafiltrate stability was substantially lower than plasma stability, emphasizing the need for immediate postfiltration analysis. Interlaboratory comparison demonstrated strong concordance, with >90% of samples differing by <±25.0%. Conclusions: A validated LC-HRMS method for quantifying unbound FLU was developed using UF. Cross-validation showed that comparable results can be achieved across laboratories when key UF parameters, such as device type and temperature, are harmonized. Because of the limited stability of FLU in ultrafiltrate, sample storage in plasma matrix is recommended. – Name: TypeDocument Label: Document Type Group: TypDoc Data: article in journal/newspaper – Name: Language Label: Language Group: Lang Data: English – Name: DOI Label: DOI Group: ID Data: 10.1097/ftd.0000000000001449 – Name: DOI Label: DOI Group: ID Data: 10.1097/FTD.0000000000001449 – Name: URL Label: Availability Group: URL Data: https://doi.org/10.1097/ftd.0000000000001449<br />https://journals.lww.com/10.1097/FTD.0000000000001449 – Name: AN Label: Accession Number Group: ID Data: edsbas.F8FDBC94 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsbas&AN=edsbas.F8FDBC94 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1097/ftd.0000000000001449 Languages: – Text: English Titles: – TitleFull: Addressing Analytical Challenges to Improve Laboratory Consistency in Unbound Flucloxacillin Measurement Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Van herteryck, Cathérine – PersonEntity: Name: NameFull: Reyns, Tim – PersonEntity: Name: NameFull: Jager, Nynke – PersonEntity: Name: NameFull: Stove, Veronique – PersonEntity: Name: NameFull: Verougstraete, Nick IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Type: published Y: 2026 Identifiers: – Type: issn-locals Value: edsbas Titles: – TitleFull: Therapeutic Drug Monitoring ; ISSN 0163-4356 1536-3694 Type: main |
| ResultId | 1 |