Academic Journal

Effect of different temperatures and penetration depths of a System B plugger in the filling of artificially created oval canals

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Effect of different temperatures and penetration depths of a System B plugger in the filling of artificially created oval canals
Συνεισφορές: Il-Young Jung, Sun-Bok Lee, Seung-Jong Lee, Chan-Young Lee, Eui-Seong Kim, Kim, Eui Seong, Lee, Seung Jong, Jung, Il Young
Στοιχεία εκδότη: Elsevier
Έτος έκδοσης: 2003
Θεματικοί όροι: Acrylic Resins, Analysis of Variance, Dental Models, Dental Pulp Cavity/anatomy & histology, Gutta-Percha, Humans, Root Canal Obturation/instrumentation, Root Canal Obturation/methods, Temperature, Tooth Apex/anatomy & histology
Time: 14561971
Περιγραφή: OBJECTIVES: The purpose of this study was to compare the gutta-percha-filled area in oval canals while varying the temperature and penetration depth of the System B plugger. STUDY DESIGN: Seventy-five resin blocks, with artificially created oval canals, were obturated by using a continuous wave technique. In groups 1, 2, and 3, the plugger was introduced to a depth of 4 mm from the apex at set temperatures of 100, 200, and 350 degrees C, respectively. In group 4, the plugger was inserted to a depth of 2 mm from the apex at a set temperature of 200 degrees C. Group 5 was obturated in the same way as group 2, and then an additional cold plugging was performed to a depth of 3 mm from the apex. The cross sections of the obturated canals were photographed, and the percentage of the gutta-percha-filled area (PGP) was measured. RESULTS: No significant differences were found between the 3 different temperature settings (P >.05). At 1 mm from the apex, group 4 showed the highest PGP (95.57% +/- 6.86), followed by group 5 (84.72% +/- 12.19), and group 2 (67.33 +/- 13.03) (P <.05). CONCLUSION: In artificially created oval canals, plugger temperature within the range used in this study did not affect the PGP. However, the penetration depth of the plugger was significantly related to PGP. ; open
Τύπος εγγράφου: article in journal/newspaper
Περιγραφή αρχείου: 453~457
Γλώσσα: English
Relation: ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS; J02443; https://ir.ymlib.yonsei.ac.kr/handle/22282913/113173; http://www.sciencedirect.com/science/article/pii/S1079210403001562; T200300201; 54184
DOI: 10.1016/S1079210403001562
Διαθεσιμότητα: https://ir.ymlib.yonsei.ac.kr/handle/22282913/113173
https://doi.org/10.1016/S1079210403001562
http://www.sciencedirect.com/science/article/pii/S1079210403001562
Rights: CC BY-NC-ND 2.0 KR ; https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ ; not free
Αριθμός Καταχώρησης: edsbas.CA063C
Βάση Δεδομένων: BASE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://ir.ymlib.yonsei.ac.kr/handle/22282913/113173#
    Name: EDS - BASE (ns324271)
    Category: fullText
    Text: View record from BASE
Header DbId: edsbas
DbLabel: BASE
An: edsbas.CA063C
RelevancyScore: 832
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 832.014282226563
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Effect of different temperatures and penetration depths of a System B plugger in the filling of artificially created oval canals
– Name: Author
  Label: Contributors
  Group: Au
  Data: Il-Young Jung&lt;br /&gt;Sun-Bok Lee&lt;br /&gt;Seung-Jong Lee&lt;br /&gt;Chan-Young Lee&lt;br /&gt;Eui-Seong Kim&lt;br /&gt;Kim, Eui Seong&lt;br /&gt;Lee, Seung Jong&lt;br /&gt;Jung, Il Young
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: Elsevier
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2003
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Acrylic+Resins%22&quot;&gt;Acrylic Resins&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Analysis+of+Variance%22&quot;&gt;Analysis of Variance&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Dental+Models%22&quot;&gt;Dental Models&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Dental+Pulp+Cavity%2Fanatomy+%26+histology%22&quot;&gt;Dental Pulp Cavity/anatomy &amp; histology&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Gutta-Percha%22&quot;&gt;Gutta-Percha&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Humans%22&quot;&gt;Humans&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Root+Canal+Obturation%2Finstrumentation%22&quot;&gt;Root Canal Obturation/instrumentation&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Root+Canal+Obturation%2Fmethods%22&quot;&gt;Root Canal Obturation/methods&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Temperature%22&quot;&gt;Temperature&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Tooth+Apex%2Fanatomy+%26+histology%22&quot;&gt;Tooth Apex/anatomy &amp; histology&lt;/searchLink&gt;
– Name: Subject
  Label: Time
  Group: Su
  Data: 14561971
– Name: Abstract
  Label: Description
  Group: Ab
  Data: OBJECTIVES: The purpose of this study was to compare the gutta-percha-filled area in oval canals while varying the temperature and penetration depth of the System B plugger. STUDY DESIGN: Seventy-five resin blocks, with artificially created oval canals, were obturated by using a continuous wave technique. In groups 1, 2, and 3, the plugger was introduced to a depth of 4 mm from the apex at set temperatures of 100, 200, and 350 degrees C, respectively. In group 4, the plugger was inserted to a depth of 2 mm from the apex at a set temperature of 200 degrees C. Group 5 was obturated in the same way as group 2, and then an additional cold plugging was performed to a depth of 3 mm from the apex. The cross sections of the obturated canals were photographed, and the percentage of the gutta-percha-filled area (PGP) was measured. RESULTS: No significant differences were found between the 3 different temperature settings (P &gt;.05). At 1 mm from the apex, group 4 showed the highest PGP (95.57% +/- 6.86), followed by group 5 (84.72% +/- 12.19), and group 2 (67.33 +/- 13.03) (P &lt;.05). CONCLUSION: In artificially created oval canals, plugger temperature within the range used in this study did not affect the PGP. However, the penetration depth of the plugger was significantly related to PGP. ; open
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: article in journal/newspaper
– Name: Format
  Label: File Description
  Group: SrcInfo
  Data: 453~457
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: NoteTitleSource
  Label: Relation
  Group: SrcInfo
  Data: ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS; J02443; https://ir.ymlib.yonsei.ac.kr/handle/22282913/113173; http://www.sciencedirect.com/science/article/pii/S1079210403001562; T200300201; 54184
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1016/S1079210403001562
– Name: URL
  Label: Availability
  Group: URL
  Data: https://ir.ymlib.yonsei.ac.kr/handle/22282913/113173&lt;br /&gt;https://doi.org/10.1016/S1079210403001562&lt;br /&gt;http://www.sciencedirect.com/science/article/pii/S1079210403001562
– Name: Copyright
  Label: Rights
  Group: Cpyrght
  Data: CC BY-NC-ND 2.0 KR ; https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ ; not free
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsbas.CA063C
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsbas&AN=edsbas.CA063C
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/S1079210403001562
    Languages:
      – Text: English
    Subjects:
      – SubjectFull: Acrylic Resins
        Type: general
      – SubjectFull: Analysis of Variance
        Type: general
      – SubjectFull: Dental Models
        Type: general
      – SubjectFull: Dental Pulp Cavity/anatomy & histology
        Type: general
      – SubjectFull: Gutta-Percha
        Type: general
      – SubjectFull: Humans
        Type: general
      – SubjectFull: Root Canal Obturation/instrumentation
        Type: general
      – SubjectFull: Root Canal Obturation/methods
        Type: general
      – SubjectFull: Temperature
        Type: general
      – SubjectFull: Tooth Apex/anatomy & histology
        Type: general
    Titles:
      – TitleFull: Effect of different temperatures and penetration depths of a System B plugger in the filling of artificially created oval canals
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Il-Young Jung
      – PersonEntity:
          Name:
            NameFull: Sun-Bok Lee
      – PersonEntity:
          Name:
            NameFull: Seung-Jong Lee
      – PersonEntity:
          Name:
            NameFull: Chan-Young Lee
      – PersonEntity:
          Name:
            NameFull: Eui-Seong Kim
      – PersonEntity:
          Name:
            NameFull: Kim, Eui Seong
      – PersonEntity:
          Name:
            NameFull: Lee, Seung Jong
      – PersonEntity:
          Name:
            NameFull: Jung, Il Young
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Type: published
              Y: 2003
          Identifiers:
            – Type: issn-locals
              Value: edsbas
            – Type: issn-locals
              Value: edsbas.oa
ResultId 1