Exploring appropriate offset values for pencil beam and Monte Carlo dose optimization in lung stereotactic body radiotherapy encompassing the effects of respiration and tumor location
| Τίτλος: | Exploring appropriate offset values for pencil beam and Monte Carlo dose optimization in lung stereotactic body radiotherapy encompassing the effects of respiration and tumor location |
|---|---|
| Συνεισφορές: | Evans, Grant (author), Shang, Charles (Thesis advisor), Florida Atlantic University (Degree grantor), Charles E. Schmidt College of Science, Department of Physics |
| Στοιχεία εκδότη: | Florida Atlantic University |
| Συλλογή: | FAU Digital Collections (Florida Atlantic University Digital Library) |
| Θεματικοί όροι: | Drug development -- Computer simulation, Image guided radiation therapy, Lung cancer -- Treatment, Monte Carlo method, Proton beams, Transport theory |
| Περιγραφή: | Evaluation of dose optimization using the Pencil Beam (PB) and Monte Carlo (MC) algorithms may allow physicists to apply dosimetric offsets to account for inaccuracies of the PB algorithm for lung cancer treatment with Stereotactic Body Radiotherapy (SBRT). 20 cases of Non-Small Cell Lung Cancer (NSCLC) were selected. Treatment plans were created with Brainlab iPlanDose® 4.1.2. The D97 of the Planning Target Volume (PTV) was normalized to 50 Gy on the Average Intensity Projection (AIP) using the fast PB and compared with MC. This exact plan with the same beam Monitor Units (MUs) was recalculated over each respiratory phase. The results show that the PB algorithm has a 2.3-2.4% less overestimation at the maximum exhalation phase than the maximum inhalation phase when compared to MC. Significantly smaller dose difference between PB and MC is also shown in plans for peripheral lesions (7.7 ± 0.7%) versus central lesions (12.7±0.8%)(p< 0.01). ; Includes bibliography. ; Thesis (M.S.)--Florida Atlantic University, 2014. ; FAU Electronic Theses and Dissertations Collection |
| Τύπος εγγράφου: | Thesis |
| Περιγραφή αρχείου: | 83 p.; application/pdf; Electronic Thesis or Dissertation |
| Γλώσσα: | English |
| Relation: | FA00004105; http://purl.flvc.org/fau/fd/FA00004105; https://fau.digital.flvc.org/islandora/object/fau%3A13442/datastream/TN/view/%20Exploring%20appropriate%20offset%20values%20for%20pencil%20beam%20and%20Monte%20Carlo%20dose%20optimization%20in%20lung%20stereotactic%20body%20radiotherapy%20encompassing%20the%20effects%20of%20respiration%20and%20tumor%20location.jpg |
| Διαθεσιμότητα: | http://purl.flvc.org/fau/fd/FA00004105 https://fau.digital.flvc.org/islandora/object/fau%3A13442/datastream/TN/view/%20Exploring%20appropriate%20offset%20values%20for%20pencil%20beam%20and%20Monte%20Carlo%20dose%20optimization%20in%20lung%20stereotactic%20body%20radiotherapy%20encompassing%20the%20effects%20of%20respiration%20and%20tumor%20location.jpg |
| Rights: | Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. ; http://rightsstatements.org/vocab/InC/1.0/ |
| Αριθμός Καταχώρησης: | edsbas.8917C01D |
| Βάση Δεδομένων: | BASE |
| FullText | Text: Availability: 0 CustomLinks: – Url: http://purl.flvc.org/fau/fd/FA00004105# Name: EDS - BASE (ns324271) Category: fullText Text: View record from BASE |
|---|---|
| Header | DbId: edsbas DbLabel: BASE An: edsbas.8917C01D RelevancyScore: 672 AccessLevel: 3 PubType: Dissertation/Thesis PubTypeId: unknown PreciseRelevancyScore: 671.999938964844 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Exploring appropriate offset values for pencil beam and Monte Carlo dose optimization in lung stereotactic body radiotherapy encompassing the effects of respiration and tumor location – Name: Author Label: Contributors Group: Au Data: Evans, Grant (author)<br />Shang, Charles (Thesis advisor)<br />Florida Atlantic University (Degree grantor)<br />Charles E. Schmidt College of Science<br />Department of Physics – Name: Publisher Label: Publisher Information Group: PubInfo Data: Florida Atlantic University – Name: Subset Label: Collection Group: HoldingsInfo Data: FAU Digital Collections (Florida Atlantic University Digital Library) – Name: Subject Label: Subject Terms Group: Su Data: <searchLink fieldCode="DE" term="%22Drug+development+--+Computer+simulation%22">Drug development -- Computer simulation</searchLink><br /><searchLink fieldCode="DE" term="%22Image+guided+radiation+therapy%22">Image guided radiation therapy</searchLink><br /><searchLink fieldCode="DE" term="%22Lung+cancer+--+Treatment%22">Lung cancer -- Treatment</searchLink><br /><searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink><br /><searchLink fieldCode="DE" term="%22Proton+beams%22">Proton beams</searchLink><br /><searchLink fieldCode="DE" term="%22Transport+theory%22">Transport theory</searchLink> – Name: Abstract Label: Description Group: Ab Data: Evaluation of dose optimization using the Pencil Beam (PB) and Monte Carlo (MC) algorithms may allow physicists to apply dosimetric offsets to account for inaccuracies of the PB algorithm for lung cancer treatment with Stereotactic Body Radiotherapy (SBRT). 20 cases of Non-Small Cell Lung Cancer (NSCLC) were selected. Treatment plans were created with Brainlab iPlanDose® 4.1.2. The D97 of the Planning Target Volume (PTV) was normalized to 50 Gy on the Average Intensity Projection (AIP) using the fast PB and compared with MC. This exact plan with the same beam Monitor Units (MUs) was recalculated over each respiratory phase. The results show that the PB algorithm has a 2.3-2.4% less overestimation at the maximum exhalation phase than the maximum inhalation phase when compared to MC. Significantly smaller dose difference between PB and MC is also shown in plans for peripheral lesions (7.7 ± 0.7%) versus central lesions (12.7±0.8%)(p< 0.01). ; Includes bibliography. ; Thesis (M.S.)--Florida Atlantic University, 2014. ; FAU Electronic Theses and Dissertations Collection – Name: TypeDocument Label: Document Type Group: TypDoc Data: Thesis – Name: Format Label: File Description Group: SrcInfo Data: 83 p.; application/pdf; Electronic Thesis or Dissertation – Name: Language Label: Language Group: Lang Data: English – Name: NoteTitleSource Label: Relation Group: SrcInfo Data: FA00004105; http://purl.flvc.org/fau/fd/FA00004105; https://fau.digital.flvc.org/islandora/object/fau%3A13442/datastream/TN/view/%20Exploring%20appropriate%20offset%20values%20for%20pencil%20beam%20and%20Monte%20Carlo%20dose%20optimization%20in%20lung%20stereotactic%20body%20radiotherapy%20encompassing%20the%20effects%20of%20respiration%20and%20tumor%20location.jpg – Name: URL Label: Availability Group: URL Data: http://purl.flvc.org/fau/fd/FA00004105<br />https://fau.digital.flvc.org/islandora/object/fau%3A13442/datastream/TN/view/%20Exploring%20appropriate%20offset%20values%20for%20pencil%20beam%20and%20Monte%20Carlo%20dose%20optimization%20in%20lung%20stereotactic%20body%20radiotherapy%20encompassing%20the%20effects%20of%20respiration%20and%20tumor%20location.jpg – Name: Copyright Label: Rights Group: Cpyrght Data: Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. ; http://rightsstatements.org/vocab/InC/1.0/ – Name: AN Label: Accession Number Group: ID Data: edsbas.8917C01D |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsbas&AN=edsbas.8917C01D |
| RecordInfo | BibRecord: BibEntity: Languages: – Text: English Subjects: – SubjectFull: Drug development -- Computer simulation Type: general – SubjectFull: Image guided radiation therapy Type: general – SubjectFull: Lung cancer -- Treatment Type: general – SubjectFull: Monte Carlo method Type: general – SubjectFull: Proton beams Type: general – SubjectFull: Transport theory Type: general Titles: – TitleFull: Exploring appropriate offset values for pencil beam and Monte Carlo dose optimization in lung stereotactic body radiotherapy encompassing the effects of respiration and tumor location Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Evans, Grant (author) – PersonEntity: Name: NameFull: Shang, Charles (Thesis advisor) – PersonEntity: Name: NameFull: Florida Atlantic University (Degree grantor) – PersonEntity: Name: NameFull: Charles E. Schmidt College of Science – PersonEntity: Name: NameFull: Department of Physics IsPartOfRelationships: – BibEntity: Identifiers: – Type: issn-locals Value: edsbas – Type: issn-locals Value: edsbas.oa |
| ResultId | 1 |