Academic Journal

Review of the mechanical behavior of different implant–abutment connections

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Review of the mechanical behavior of different implant–abutment connections
Συγγραφείς: Vinhas, Ana Sofia, Aroso, Carlos, Salazar, Filomena, López-Jarana, Paula, Ríos-Santos, J.V., Herrero-Climent, Mariano
Συνεισφορές: Universidad de Sevilla. Departamento de Estomatología
Στοιχεία εκδότη: Mdpi
Έτος έκδοσης: 2024
Συλλογή: idUS - Deposito de Investigación Universidad de Sevilla
Θεματικοί όροι: Implant–abutment connection, Preload, Tightening torque, Cyclicloading, Misfit, Microleakage
Περιγραφή: Introduction: Different implant–abutment connections have been developed to reduce mechanical and biological failure. The most frequent complications are loss of preload, screw loosening, abutment or implant fracture, deformations at the different interfaces, and bacterial microleakage. Aim: To review the evidence indicating whether the implant–abutment connection type is significant regarding the following issues: (1) maintenance of the preload in static and dynamic in vitro studies; (2) assessment of possible deformations at the implant–abutment interfaces, after repeated application of the tightening torque; (3) evaluation of the sealing capability of different implant connections against microleakage. Materials and Methods: In June 2020, an electronic literature search was performed in Medline, EBSCO host, and PubMed databases. The search was focused on the ability of different implant connections to maintain preload, resist deformation after tightening and retightening, and prevent microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full-text reading. Results: The literature search conducted for this review initially resulted in 68 articles, among which 19 articles and 1 systematic review fulfilled the criteria for inclusion. The studies were divided according to the three proposed objectives, with some studies falling into more than one category (maintenance of preload, surface abutment–implant deformation, and resistance to microleakage). Conclusions: Conical abutment appears to result in fewer mechanical complications, such as screw loosening or fractures, and higher torque preservation. After SEM evaluation, damage was observed in the threads of the abutment screws, before and after loading in internal and external connections. Internal hexagon implants and predominantly internal conical (Morse taper) implants showed less microleakage in dynamic loading conditions. We suggest further studies to ...
Τύπος εγγράφου: article in journal/newspaper
Γλώσσα: English
Relation: International journal of environmental research and public health, 17 (22), 8685.; https://www.mdpi.com/1660-4601/17/22/8685; https://idus.us.es/handle//11441/161817
Διαθεσιμότητα: https://idus.us.es/handle//11441/161817
Rights: Atribución 4.0 Internacional ; http://creativecommons.org/licenses/by/4.0/ ; info:eu-repo/semantics/openAccess
Αριθμός Καταχώρησης: edsbas.5D382F1
Βάση Δεδομένων: BASE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://idus.us.es/handle//11441/161817#
    Name: EDS - BASE (ns324271)
    Category: fullText
    Text: View record from BASE
Header DbId: edsbas
DbLabel: BASE
An: edsbas.5D382F1
RelevancyScore: 950
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 949.707946777344
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Review of the mechanical behavior of different implant–abutment connections
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Vinhas%2C+Ana+Sofia%22">Vinhas, Ana Sofia</searchLink><br /><searchLink fieldCode="AR" term="%22Aroso%2C+Carlos%22">Aroso, Carlos</searchLink><br /><searchLink fieldCode="AR" term="%22Salazar%2C+Filomena%22">Salazar, Filomena</searchLink><br /><searchLink fieldCode="AR" term="%22López-Jarana%2C+Paula%22">López-Jarana, Paula</searchLink><br /><searchLink fieldCode="AR" term="%22Ríos-Santos%2C+J%2EV%2E%22">Ríos-Santos, J.V.</searchLink><br /><searchLink fieldCode="AR" term="%22Herrero-Climent%2C+Mariano%22">Herrero-Climent, Mariano</searchLink>
– Name: Author
  Label: Contributors
  Group: Au
  Data: Universidad de Sevilla. Departamento de Estomatología
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: Mdpi
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2024
– Name: Subset
  Label: Collection
  Group: HoldingsInfo
  Data: idUS - Deposito de Investigación Universidad de Sevilla
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Implant–abutment+connection%22">Implant–abutment connection</searchLink><br /><searchLink fieldCode="DE" term="%22Preload%22">Preload</searchLink><br /><searchLink fieldCode="DE" term="%22Tightening+torque%22">Tightening torque</searchLink><br /><searchLink fieldCode="DE" term="%22Cyclicloading%22">Cyclicloading</searchLink><br /><searchLink fieldCode="DE" term="%22Misfit%22">Misfit</searchLink><br /><searchLink fieldCode="DE" term="%22Microleakage%22">Microleakage</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: Introduction: Different implant–abutment connections have been developed to reduce mechanical and biological failure. The most frequent complications are loss of preload, screw loosening, abutment or implant fracture, deformations at the different interfaces, and bacterial microleakage. Aim: To review the evidence indicating whether the implant–abutment connection type is significant regarding the following issues: (1) maintenance of the preload in static and dynamic in vitro studies; (2) assessment of possible deformations at the implant–abutment interfaces, after repeated application of the tightening torque; (3) evaluation of the sealing capability of different implant connections against microleakage. Materials and Methods: In June 2020, an electronic literature search was performed in Medline, EBSCO host, and PubMed databases. The search was focused on the ability of different implant connections to maintain preload, resist deformation after tightening and retightening, and prevent microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full-text reading. Results: The literature search conducted for this review initially resulted in 68 articles, among which 19 articles and 1 systematic review fulfilled the criteria for inclusion. The studies were divided according to the three proposed objectives, with some studies falling into more than one category (maintenance of preload, surface abutment–implant deformation, and resistance to microleakage). Conclusions: Conical abutment appears to result in fewer mechanical complications, such as screw loosening or fractures, and higher torque preservation. After SEM evaluation, damage was observed in the threads of the abutment screws, before and after loading in internal and external connections. Internal hexagon implants and predominantly internal conical (Morse taper) implants showed less microleakage in dynamic loading conditions. We suggest further studies to ...
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: article in journal/newspaper
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: NoteTitleSource
  Label: Relation
  Group: SrcInfo
  Data: International journal of environmental research and public health, 17 (22), 8685.; https://www.mdpi.com/1660-4601/17/22/8685; https://idus.us.es/handle//11441/161817
– Name: URL
  Label: Availability
  Group: URL
  Data: https://idus.us.es/handle//11441/161817
– Name: Copyright
  Label: Rights
  Group: Cpyrght
  Data: Atribución 4.0 Internacional ; http://creativecommons.org/licenses/by/4.0/ ; info:eu-repo/semantics/openAccess
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsbas.5D382F1
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsbas&AN=edsbas.5D382F1
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Text: English
    Subjects:
      – SubjectFull: Implant–abutment connection
        Type: general
      – SubjectFull: Preload
        Type: general
      – SubjectFull: Tightening torque
        Type: general
      – SubjectFull: Cyclicloading
        Type: general
      – SubjectFull: Misfit
        Type: general
      – SubjectFull: Microleakage
        Type: general
    Titles:
      – TitleFull: Review of the mechanical behavior of different implant–abutment connections
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Vinhas, Ana Sofia
      – PersonEntity:
          Name:
            NameFull: Aroso, Carlos
      – PersonEntity:
          Name:
            NameFull: Salazar, Filomena
      – PersonEntity:
          Name:
            NameFull: López-Jarana, Paula
      – PersonEntity:
          Name:
            NameFull: Ríos-Santos, J.V.
      – PersonEntity:
          Name:
            NameFull: Herrero-Climent, Mariano
      – PersonEntity:
          Name:
            NameFull: Universidad de Sevilla. Departamento de Estomatología
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-locals
              Value: edsbas
            – Type: issn-locals
              Value: edsbas.oa
ResultId 1