Λεπτομέρειες βιβλιογραφικής εγγραφής
| Τίτλος: |
Resonance frequency analysis by the Osstell system, using the transducer screwed to different healings abutments |
| Συγγραφείς: |
Herrero-Climent, Mariano, Díaz Castro, Carmen María, Chereguini Fernández, Carlos, Falcao, Carlos, Gil, Francisco Javier, Ríos-Santos, J.V. |
| Συνεισφορές: |
Universidad de Sevilla. Departamento de Estomatología |
| Στοιχεία εκδότη: |
SPEMD-Sociedad portuguesa estomatologia & medicina dentaria |
| Έτος έκδοσης: |
2024 |
| Συλλογή: |
idUS - Deposito de Investigación Universidad de Sevilla |
| Θεματικοί όροι: |
Abutment design, Bone implant interface, Dental implants, Osseointegration |
| Περιγραφή: |
Objectives: compare the ISQ values obtained by the Osstell ISQ, screwing the Smarpeg directly to the implant or to the new designed healing abutments of 2, 3.5 and 5 mm of height. Methods: 60 rough surface implants were placed in 4 bovine ribs. 30 standard and 30 prototype implants were divided to group A and B, respectively. All were inserted with a torque of 30 N/ cm2, so that the rough/smooth interface was placed at bone crest level (the distance between the implants needed to be at least 4 mm). Primary stability was measured by resonance frequency analysis (RFA) with the Osstell ISQ transducer directly to the implant or over three Smartpeg screwed to the top of three different healing abutments of 2, 3.5 and 5 mm of height. Results: The mean ISQ of the prototype group is 73.9 ± 5.3 and of the standard one is 79.8 ± 3.7. The mean ISQ values according to where the Smartpeg is screwed to were 76.2 ± 4.47 and 75.69 ± 4.7 when the Smartpeg was screwed directly to the implant; 78.2 ± 5.78, 77.3 ± 5.90, 76.0 ± 5.90 when the transducer was screwed to the abutments of 2, 3.5 and 5 mm of height respectively. Conclusions: It may be concluded from the present investigation that similar ISQ values could be obtained measuring the RFA with the transducer screwed directly to the implant or to healing abutments of different heights, in an accurate and reproducible way. (Rev Port Esto matol Med Dent Cir Maxilofac. 2017;58(2):91-96. |
| Τύπος εγγράφου: |
article in journal/newspaper |
| Γλώσσα: |
English |
| Relation: |
Revista portuguesa de estomatologia medicina dentaria e cirurgia maxilofacial, 58 (2), 91-966.; https://revista.spemd.pt/article/21; https://idus.us.es/handle//11441/161836 |
| Διαθεσιμότητα: |
https://idus.us.es/handle//11441/161836 |
| Rights: |
Attribution-NonCommercial-NoDerivatives 4.0 Internacional ; http://creativecommons.org/licenses/by-nc-nd/4.0/ ; info:eu-repo/semantics/openAccess |
| Αριθμός Καταχώρησης: |
edsbas.40E2D0E5 |
| Βάση Δεδομένων: |
BASE |