Academic Journal

A microcomputer based non-invasive cardiopulmonary monitor using a microwave interferometer

Bibliographic Details
Title: A microcomputer based non-invasive cardiopulmonary monitor using a microwave interferometer
Authors: Basu, Tanmoy K.
Source: Theses
Publisher Information: Digital Commons @ NJIT
Publication Year: 1989
Collection: Digital Commons @ New Jersey Institute of Technology (NJIT)
Subject Terms: Interferometer, Microwave devices, Electrocardiography, Signal processing -- Data processing, Electrical and Electronics
Description: With a microwave interferometer the vibrational velocity of the anterior (front), as well as posterior (back) chest wall can be monitored and recorded. The recorded signals are a reflection of the mechanical cardiac activity within the chest cavity, as opposed to Electrocardiogram (ECG) which is a reflection of the electrical cardiac activity. The interferometer recordings are obtained with no physical contact between the instrument and the subject. Moreover, the subject can be fully clothed since microwave energy readily passes through normal dry clothing. A microwave interferometer that is capable of detecting the vibrational velocity of the surfaces of the chest cavity (anterior and posterior) has been described in detail in the thesis. The objective of this research work is to monitor, record and analyze these vibrational characteristics of the chest wall using the microwave interferometer from co-operative healthy, normal subjects, both males as well as females, and thus to evaluate the possibility of using this instrument as a non-invasive and non-contacting cardiopulmonary monitor. The recordings from an ECG are very well understood by doctors and engineers today. By studying the signals obtained from the microwave interferometer with the ECG as a timing reference, and bearing in mind that certain mechanical cardiac events, such as valves opening and closing occur at certain points in the RR interval of the ECG, an attempt has been made to identify a common 'signature' or repetitive vibration pattern of the chest wall in normal, healthy male and female subjects. The interferometer data from one subject is autocorrelated to accentuate those features that are repetitive and also to attenuate the non-repetitive features. High amplitude velocity peaks are noticed at similar times within each cardiac cycle . In order to relate the timing of the peaks in the raw interferometer signal to the timing of certain known events in the cardiac cycle, such as the R wave of the ECG (recorded simultaneously), the ...
Document Type: text
File Description: application/pdf
Language: unknown
Relation: https://digitalcommons.njit.edu/theses/2722; https://digitalcommons.njit.edu/context/theses/article/3736/viewcontent/njit_etd1989_070.pdf
Availability: https://digitalcommons.njit.edu/theses/2722
https://digitalcommons.njit.edu/context/theses/article/3736/viewcontent/njit_etd1989_070.pdf
Accession Number: edsbas.36F1CE48
Database: BASE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://digitalcommons.njit.edu/theses/2722#
    Name: EDS - BASE (ns324271)
    Category: fullText
    Text: View record from BASE
Header DbId: edsbas
DbLabel: BASE
An: edsbas.36F1CE48
RelevancyScore: 753
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 753.149658203125
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: A microcomputer based non-invasive cardiopulmonary monitor using a microwave interferometer
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Basu%2C+Tanmoy+K%2E%22">Basu, Tanmoy K.</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: Theses
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: Digital Commons @ NJIT
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 1989
– Name: Subset
  Label: Collection
  Group: HoldingsInfo
  Data: Digital Commons @ New Jersey Institute of Technology (NJIT)
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Interferometer%22">Interferometer</searchLink><br /><searchLink fieldCode="DE" term="%22Microwave+devices%22">Microwave devices</searchLink><br /><searchLink fieldCode="DE" term="%22Electrocardiography%22">Electrocardiography</searchLink><br /><searchLink fieldCode="DE" term="%22Signal+processing+--+Data+processing%22">Signal processing -- Data processing</searchLink><br /><searchLink fieldCode="DE" term="%22Electrical+and+Electronics%22">Electrical and Electronics</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: With a microwave interferometer the vibrational velocity of the anterior (front), as well as posterior (back) chest wall can be monitored and recorded. The recorded signals are a reflection of the mechanical cardiac activity within the chest cavity, as opposed to Electrocardiogram (ECG) which is a reflection of the electrical cardiac activity. The interferometer recordings are obtained with no physical contact between the instrument and the subject. Moreover, the subject can be fully clothed since microwave energy readily passes through normal dry clothing. A microwave interferometer that is capable of detecting the vibrational velocity of the surfaces of the chest cavity (anterior and posterior) has been described in detail in the thesis. The objective of this research work is to monitor, record and analyze these vibrational characteristics of the chest wall using the microwave interferometer from co-operative healthy, normal subjects, both males as well as females, and thus to evaluate the possibility of using this instrument as a non-invasive and non-contacting cardiopulmonary monitor. The recordings from an ECG are very well understood by doctors and engineers today. By studying the signals obtained from the microwave interferometer with the ECG as a timing reference, and bearing in mind that certain mechanical cardiac events, such as valves opening and closing occur at certain points in the RR interval of the ECG, an attempt has been made to identify a common 'signature' or repetitive vibration pattern of the chest wall in normal, healthy male and female subjects. The interferometer data from one subject is autocorrelated to accentuate those features that are repetitive and also to attenuate the non-repetitive features. High amplitude velocity peaks are noticed at similar times within each cardiac cycle . In order to relate the timing of the peaks in the raw interferometer signal to the timing of certain known events in the cardiac cycle, such as the R wave of the ECG (recorded simultaneously), the ...
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: text
– Name: Format
  Label: File Description
  Group: SrcInfo
  Data: application/pdf
– Name: Language
  Label: Language
  Group: Lang
  Data: unknown
– Name: NoteTitleSource
  Label: Relation
  Group: SrcInfo
  Data: https://digitalcommons.njit.edu/theses/2722; https://digitalcommons.njit.edu/context/theses/article/3736/viewcontent/njit_etd1989_070.pdf
– Name: URL
  Label: Availability
  Group: URL
  Data: https://digitalcommons.njit.edu/theses/2722<br />https://digitalcommons.njit.edu/context/theses/article/3736/viewcontent/njit_etd1989_070.pdf
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsbas.36F1CE48
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsbas&AN=edsbas.36F1CE48
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Text: unknown
    Subjects:
      – SubjectFull: Interferometer
        Type: general
      – SubjectFull: Microwave devices
        Type: general
      – SubjectFull: Electrocardiography
        Type: general
      – SubjectFull: Signal processing -- Data processing
        Type: general
      – SubjectFull: Electrical and Electronics
        Type: general
    Titles:
      – TitleFull: A microcomputer based non-invasive cardiopulmonary monitor using a microwave interferometer
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Basu, Tanmoy K.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Type: published
              Y: 1989
          Identifiers:
            – Type: issn-locals
              Value: edsbas
            – Type: issn-locals
              Value: edsbas.oa
          Titles:
            – TitleFull: Theses
              Type: main
ResultId 1