Academic Journal

The evaluation of measuring devices instrumental errors influence on informative parameters measuring accuracy

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: The evaluation of measuring devices instrumental errors influence on informative parameters measuring accuracy
Πηγή: Information systems, mechanics and control; No. 15 (2016); 11-18
Информационные системы, механика и управление; № 15 (2016); 11-18
Інформаційні системи, механіка та керування; № 15 (2016); 11-18
Στοιχεία εκδότη: FASS, NTUU "Igor Sikorsky Kyiv Polytecnic Institute", 2016.
Έτος έκδοσης: 2016
Θεματικοί όροι: інформативні параметри, informative parameters, информативные параметры, інструментальна похибка, instrumental error, инструментальная погрешность
Περιγραφή: In the developed measuring tools measuring methods were implemented for informative parameters of harmonic signals using the discrete Fourier transform (DFT) and correction of measuring errors forphase difference and amplitude. Designed layouts based on the virtual instruments to the measuring instruments demonstrate the advantages of the method DFT, allow us to determine the specified metrological characteristics and to correct the errors of their measurement.As a comparing result values of error for estimate value of the phase difference without correction and error estimation of the phase difference with correction we clarified, that the corrective edits in designed phasemeter reduce more than factor 10 the level of error values of the measurement result of the phase difference in comparison with the results without applying a correction.The estimation error of the phase difference with correction has a back-quadratic dependence with the number of analyzed periods of the signal, which sharply decreases already when you change the number of periods from one to four.The accuracy of the calibrator phase shifts is determined by the instrumental error of the DAC and methodical error of creating signal and depends on the number of samples per signal period.The filters affect to error of the calibrator phase shifts can be minimized by ensuring the identity of their phase-and-frequency characteristics.Using more perfect methods of analog-to-digital conversion will improve performance, expand the bandwidth of the signals and increase the ratio signal/noise. Note that errors were made on the stage of analog-to-digital conversion, are difficult to separate from the converted signal and completely eliminate them during further digital processing. Therefore, you should pay attention to the value of the instrumental errors of the ADC and DAC.
Рассмотрено влияние инструментальных погрешностей, обусловленных использованием АЦП и ЦАП, на точность измерения информативных параметров (амплитуды и разности фаз) гармонических сигналов в разработанных средствах измерений (фазометре, калибраторе фазовых сдвигов, автоматизированном рабочем месте метролога).
Розглянуто вплив інструментальних похибок, обумовлених використанням АЦП і ЦАП, на точність вимірювання інформативних параметрів (амплітуди і різниці фаз) гармонічних сигналів у розроблених засобах вимірювань (фазометрі, калібраторі фазових зсувів, автоматизованому робочому місці метролога)
Τύπος εγγράφου: Article
Περιγραφή αρχείου: application/pdf
Γλώσσα: Ukrainian
ISSN: 2219-3804
2519-2256
Σύνδεσμος πρόσβασης: http://ismc.kpi.ua/article/view/85142
Rights: CC BY NC ND
Αριθμός Καταχώρησης: edsair.scientific.p..f9fbc7f0c7a604734b58d78f36fbfd61
Βάση Δεδομένων: OpenAIRE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://explore.openaire.eu/search/publication?articleId=scientific_p%3A%3Af9fbc7f0c7a604734b58d78f36fbfd61
    Name: EDS - OpenAIRE (ns324271)
    Category: fullText
    Text: View record at OpenAIRE
Header DbId: edsair
DbLabel: OpenAIRE
An: edsair.scientific.p..f9fbc7f0c7a604734b58d78f36fbfd61
RelevancyScore: 788
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 787.539306640625
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: The evaluation of measuring devices instrumental errors influence on informative parameters measuring accuracy
– Name: TitleSource
  Label: Source
  Group: Src
  Data: Information systems, mechanics and control; No. 15 (2016); 11-18<br />Информационные системы, механика и управление; № 15 (2016); 11-18<br />Інформаційні системи, механіка та керування; № 15 (2016); 11-18
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: FASS, NTUU "Igor Sikorsky Kyiv Polytecnic Institute", 2016.
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2016
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22інформативні+параметри%22">інформативні параметри</searchLink><br /><searchLink fieldCode="DE" term="%22informative+parameters%22">informative parameters</searchLink><br /><searchLink fieldCode="DE" term="%22информативные+параметры%22">информативные параметры</searchLink><br /><searchLink fieldCode="DE" term="%22інструментальна+похибка%22">інструментальна похибка</searchLink><br /><searchLink fieldCode="DE" term="%22instrumental+error%22">instrumental error</searchLink><br /><searchLink fieldCode="DE" term="%22инструментальная+погрешность%22">инструментальная погрешность</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: In the developed measuring tools measuring methods were implemented for informative parameters of harmonic signals using the discrete Fourier transform (DFT) and correction of measuring errors forphase difference and amplitude. Designed layouts based on the virtual instruments to the measuring instruments demonstrate the advantages of the method DFT, allow us to determine the specified metrological characteristics and to correct the errors of their measurement.As a comparing result values of error for estimate value of the phase difference without correction and error estimation of the phase difference with correction we clarified, that the corrective edits in designed phasemeter reduce more than factor 10 the level of error values of the measurement result of the phase difference in comparison with the results without applying a correction.The estimation error of the phase difference with correction has a back-quadratic dependence with the number of analyzed periods of the signal, which sharply decreases already when you change the number of periods from one to four.The accuracy of the calibrator phase shifts is determined by the instrumental error of the DAC and methodical error of creating signal and depends on the number of samples per signal period.The filters affect to error of the calibrator phase shifts can be minimized by ensuring the identity of their phase-and-frequency characteristics.Using more perfect methods of analog-to-digital conversion will improve performance, expand the bandwidth of the signals and increase the ratio signal/noise. Note that errors were made on the stage of analog-to-digital conversion, are difficult to separate from the converted signal and completely eliminate them during further digital processing. Therefore, you should pay attention to the value of the instrumental errors of the ADC and DAC.<br />Рассмотрено влияние инструментальных погрешностей, обусловленных использованием АЦП и ЦАП, на точность измерения информативных параметров (амплитуды и разности фаз) гармонических сигналов в разработанных средствах измерений (фазометре, калибраторе фазовых сдвигов, автоматизированном рабочем месте метролога).<br />Розглянуто вплив інструментальних похибок, обумовлених використанням АЦП і ЦАП, на точність вимірювання інформативних параметрів (амплітуди і різниці фаз) гармонічних сигналів у розроблених засобах вимірювань (фазометрі, калібраторі фазових зсувів, автоматизованому робочому місці метролога)
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: Article
– Name: Format
  Label: File Description
  Group: SrcInfo
  Data: application/pdf
– Name: Language
  Label: Language
  Group: Lang
  Data: Ukrainian
– Name: ISSN
  Label: ISSN
  Group: ISSN
  Data: 2219-3804<br />2519-2256
– Name: URL
  Label: Access URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="http://ismc.kpi.ua/article/view/85142" linkWindow="_blank">http://ismc.kpi.ua/article/view/85142</link>
– Name: Copyright
  Label: Rights
  Group: Cpyrght
  Data: CC BY NC ND
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsair.scientific.p..f9fbc7f0c7a604734b58d78f36fbfd61
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsair&AN=edsair.scientific.p..f9fbc7f0c7a604734b58d78f36fbfd61
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Text: Ukrainian
    Subjects:
      – SubjectFull: інформативні параметри
        Type: general
      – SubjectFull: informative parameters
        Type: general
      – SubjectFull: информативные параметры
        Type: general
      – SubjectFull: інструментальна похибка
        Type: general
      – SubjectFull: instrumental error
        Type: general
      – SubjectFull: инструментальная погрешность
        Type: general
    Titles:
      – TitleFull: The evaluation of measuring devices instrumental errors influence on informative parameters measuring accuracy
        Type: main
  BibRelationships:
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 10
              M: 10
              Type: published
              Y: 2016
          Identifiers:
            – Type: issn-print
              Value: 22193804
            – Type: issn-print
              Value: 25192256
            – Type: issn-locals
              Value: edsair
            – Type: issn-locals
              Value: edsairFT
          Titles:
            – TitleFull: Information systems, mechanics and control
              Type: main
ResultId 1