Academic Journal

Mathematical and computer modeling of a new endoprosthesis with a carbon-carbon composite for interbody fusion of a lumbar spine

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Mathematical and computer modeling of a new endoprosthesis with a carbon-carbon composite for interbody fusion of a lumbar spine
Συγγραφείς: Korzh, Mykola, Radchenko, Volodymyr, Kutsenko, Volodymyr, Popov, Andrey, Veretelnik, Oleg, Timchenko, Iryna, Tkachuk, Mykola, Perfiliev, Olexandr
Πηγή: ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS; No. 1 (2020); 46-53
№ 1 (2020); 46-53
Ортопедія, травматологія та протезування; № 1 (2020); 46-53
Στοιχεία εκδότη: Orthopaedica, Traumatology, and Prosthetics, 2020.
Έτος έκδοσης: 2020
Θεματικοί όροι: міжтіловий спондилодез, implant, углерод-углеродный композит, interbody fusion, конечно-элементные модели, тіло хребця, скінченно-елементні моделі, напружено-деформований стан, тело позвонка, імплантат, напряженно-деформированное состояние, межтеловой спондилодез, контактний тиск, carbon-carbon composite, finite-element models, контактное давление, stress-strain state, имплантат, vertebral body, вуглець-вуглецевий композит, contact pressure
Περιγραφή: Endoprostheses for interbody fusion should have not only biocompatibility and high strength characteristics, but also good visualization with additional research methods (CT, MRI). One such material is carbon. Aim: using mathematical modeling (the finite element method) to develop a model of the interbody prosthesis from a carbon-carbon composite and evaluate the stress-strain state of the vertebral body-implant system. Methods: models created in SolidWorks software. 18 design schemes with endoprostheses from a carbon-carbon composite were developed and studied. Bending load was carried out by angular displacements (2°), compressive — by applying a force of 500 N to the upper cubic element. Additional symmetry conditions were also simulated. Results: a parametric model of the biomechanical system of the lumbar spine was constructed. The smallest equivalent stresses were obtained in the design scheme M17, and the largest — in M13. In the bone elements of the systems, they did not exceed the ultimate strength limits for cortical (160 MPa) and cancellous (18–22 MPa) bones. Contact pressure and displacement are determined for all design schemes. Conclusions: as a result of the numerical values and distribution fields of the components of the stress-strain state in the elements of the studied systems, it was found that the use of the proposed endoprosthesis made of a carbon-carbon composite, the geometric parameters of which correspond to the design scheme M17, is effective for achieving additional stabilization in the system «vertebral body – implant».
Τύπος εγγράφου: Article
Περιγραφή αρχείου: application/pdf
ISSN: 2518-1882
0030-5987
DOI: 10.15674/0030-59872020146-53
Σύνδεσμος πρόσβασης: http://otp-journal.com.ua/article/download/200791/200813
http://otp-journal.com.ua/article/view/200791
Rights: CC BY
Αριθμός Καταχώρησης: edsair.doi.dedup.....cffb60837c057f70a72a1fa1b2dd67d0
Βάση Δεδομένων: OpenAIRE
Περιγραφή
ISSN:25181882
00305987
DOI:10.15674/0030-59872020146-53