Two different methods to digitally visualize continuous electrocochleography potentials during cochlear implantation: a first description of feasibility

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Two different methods to digitally visualize continuous electrocochleography potentials during cochlear implantation: a first description of feasibility
Συγγραφείς: Theda Eichler, Antonia Lakomek, Laura Waschkies, Moritz Meyer, Nadia Sadok, Stephan Lang, Diana Arweiler-Harbeck
Πηγή: Eur Arch Otorhinolaryngol
Στοιχεία εκδότη: Springer Science and Business Media LLC, 2024.
Έτος έκδοσης: 2024
Θεματικοί όροι: Male, Adult, Hearing preservation, Female [MeSH], Aged [MeSH], Adult [MeSH], Humans [MeSH], Software [MeSH], Intraoperative electrocochleography, Middle Aged [MeSH], Audiometry, Evoked Response/methods [MeSH], Feasibility Studies [MeSH], Digital microscope imaging, Otology, Cochlear Implantation/methods [MeSH], Male [MeSH], Cochlear implantation, Cochlear Implants [MeSH], Medizin, Middle Aged, Cochlear Implantation, Audiometry, Evoked Response, Cochlear Implants, Humans, Feasibility Studies, Female, Software, Aged
Περιγραφή: Purpose The study explores the potential of real-time electrocochleographic potentials (ECochG) visualization during electrode insertion using digital microscopes such as RoboticScope (BHS®). Collaborative software development of the MAESTRO Software (MED-EL®) offers continuous ECochG monitoring during implantation and postoperative hearing evaluation, addressing previous time constraints. The study aims to assess software applicability and the impact of real-time visualization on long-term residual hearing preservation. Methods Eight patients with residual hearing underwent cochlear implantation with Flex26 or Flex28 electrode according to the Otoplan evaluation. ECochG responses were measured and visualized during electrode insertion, with insertion times recorded. Two randomized display methods (graph and arrows) tracked ECochG potentials. Postoperative behavioral thresholds determined hearing preservation. Successful real-time intraoperative ECochG visualization was achieved in all cases, enabling surgeon adaptation. Mean electrode insertion time was 114 s, with postoperative thresholds comparable to preoperative values. Visualization did not affect surgeon workload. ECochG amplitudes differed between patients with and without residual hearing. Conclusion The study demonstrates effective implementation of advanced ECochG software combined with real-time visualization, enabling residual hearing preservation during CI. Visualization had no apparent effect on surgeon performance or workload. Future investigation involving a larger population will assess the long-term impact of ECochG on hearing threshold and structure preservation.
Τύπος εγγράφου: Article
Other literature type
Γλώσσα: English
ISSN: 1434-4726
0937-4477
DOI: 10.1007/s00405-023-08400-3
Σύνδεσμος πρόσβασης: https://pubmed.ncbi.nlm.nih.gov/38170210
https://repository.publisso.de/resource/frl:6517933
https://www.ncbi.nlm.nih.gov/pubmed/38170210
https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&origin=inward&scp=85181248769
https://doi.org/10.1007/s00405-023-08400-3
Rights: CC BY
Αριθμός Καταχώρησης: edsair.doi.dedup.....68a1e0540839c0c3630f903a8a738184
Βάση Δεδομένων: OpenAIRE
FullText Links:
  – Type: other
    Url: https://resolver.ebsco.com:443/public/rma-ftfapi/ejs/direct?AccessToken=4946826DA06E47C8710A&Show=Object
Text:
  Availability: 0
CustomLinks:
  – Url: https://explore.openaire.eu/search/publication?articleId=doi_dedup___%3A%3A68a1e0540839c0c3630f903a8a738184
    Name: EDS - OpenAIRE (ns324271)
    Category: fullText
    Text: View record at OpenAIRE
  – Url: https://dx.doi.org/doi:10.1007/s00405-023-08400-3
    Name: EDS - Springer Nature Journals (s7799221)
    Category: fullText
    Text: View record at Springer
Header DbId: edsair
DbLabel: OpenAIRE
An: edsair.doi.dedup.....68a1e0540839c0c3630f903a8a738184
RelevancyScore: 964
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 964.415649414063
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Two different methods to digitally visualize continuous electrocochleography potentials during cochlear implantation: a first description of feasibility
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Theda+Eichler%22">Theda Eichler</searchLink><br /><searchLink fieldCode="AR" term="%22Antonia+Lakomek%22">Antonia Lakomek</searchLink><br /><searchLink fieldCode="AR" term="%22Laura+Waschkies%22">Laura Waschkies</searchLink><br /><searchLink fieldCode="AR" term="%22Moritz+Meyer%22">Moritz Meyer</searchLink><br /><searchLink fieldCode="AR" term="%22Nadia+Sadok%22">Nadia Sadok</searchLink><br /><searchLink fieldCode="AR" term="%22Stephan+Lang%22">Stephan Lang</searchLink><br /><searchLink fieldCode="AR" term="%22Diana+Arweiler-Harbeck%22">Diana Arweiler-Harbeck</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: Eur Arch Otorhinolaryngol
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: Springer Science and Business Media LLC, 2024.
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2024
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Male%22">Male</searchLink><br /><searchLink fieldCode="DE" term="%22Adult%22">Adult</searchLink><br /><searchLink fieldCode="DE" term="%22Hearing+preservation%22">Hearing preservation</searchLink><br /><searchLink fieldCode="DE" term="%22Female+[MeSH]%22">Female [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Aged+[MeSH]%22">Aged [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Adult+[MeSH]%22">Adult [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Humans+[MeSH]%22">Humans [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Software+[MeSH]%22">Software [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Intraoperative+electrocochleography%22">Intraoperative electrocochleography</searchLink><br /><searchLink fieldCode="DE" term="%22Middle+Aged+[MeSH]%22">Middle Aged [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Audiometry%2C+Evoked+Response%2Fmethods+[MeSH]%22">Audiometry, Evoked Response/methods [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Feasibility+Studies+[MeSH]%22">Feasibility Studies [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Digital+microscope+imaging%22">Digital microscope imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Otology%22">Otology</searchLink><br /><searchLink fieldCode="DE" term="%22Cochlear+Implantation%2Fmethods+[MeSH]%22">Cochlear Implantation/methods [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Male+[MeSH]%22">Male [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Cochlear+implantation%22">Cochlear implantation</searchLink><br /><searchLink fieldCode="DE" term="%22Cochlear+Implants+[MeSH]%22">Cochlear Implants [MeSH]</searchLink><br /><searchLink fieldCode="DE" term="%22Medizin%22">Medizin</searchLink><br /><searchLink fieldCode="DE" term="%22Middle+Aged%22">Middle Aged</searchLink><br /><searchLink fieldCode="DE" term="%22Cochlear+Implantation%22">Cochlear Implantation</searchLink><br /><searchLink fieldCode="DE" term="%22Audiometry%2C+Evoked+Response%22">Audiometry, Evoked Response</searchLink><br /><searchLink fieldCode="DE" term="%22Cochlear+Implants%22">Cochlear Implants</searchLink><br /><searchLink fieldCode="DE" term="%22Humans%22">Humans</searchLink><br /><searchLink fieldCode="DE" term="%22Feasibility+Studies%22">Feasibility Studies</searchLink><br /><searchLink fieldCode="DE" term="%22Female%22">Female</searchLink><br /><searchLink fieldCode="DE" term="%22Software%22">Software</searchLink><br /><searchLink fieldCode="DE" term="%22Aged%22">Aged</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: Purpose The study explores the potential of real-time electrocochleographic potentials (ECochG) visualization during electrode insertion using digital microscopes such as RoboticScope (BHS®). Collaborative software development of the MAESTRO Software (MED-EL®) offers continuous ECochG monitoring during implantation and postoperative hearing evaluation, addressing previous time constraints. The study aims to assess software applicability and the impact of real-time visualization on long-term residual hearing preservation. Methods Eight patients with residual hearing underwent cochlear implantation with Flex26 or Flex28 electrode according to the Otoplan evaluation. ECochG responses were measured and visualized during electrode insertion, with insertion times recorded. Two randomized display methods (graph and arrows) tracked ECochG potentials. Postoperative behavioral thresholds determined hearing preservation. Successful real-time intraoperative ECochG visualization was achieved in all cases, enabling surgeon adaptation. Mean electrode insertion time was 114 s, with postoperative thresholds comparable to preoperative values. Visualization did not affect surgeon workload. ECochG amplitudes differed between patients with and without residual hearing. Conclusion The study demonstrates effective implementation of advanced ECochG software combined with real-time visualization, enabling residual hearing preservation during CI. Visualization had no apparent effect on surgeon performance or workload. Future investigation involving a larger population will assess the long-term impact of ECochG on hearing threshold and structure preservation.
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: Article<br />Other literature type
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: ISSN
  Label: ISSN
  Group: ISSN
  Data: 1434-4726<br />0937-4477
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1007/s00405-023-08400-3
– Name: URL
  Label: Access URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="https://pubmed.ncbi.nlm.nih.gov/38170210" linkWindow="_blank">https://pubmed.ncbi.nlm.nih.gov/38170210</link><br /><link linkTarget="URL" linkTerm="https://repository.publisso.de/resource/frl:6517933" linkWindow="_blank">https://repository.publisso.de/resource/frl:6517933</link><br /><link linkTarget="URL" linkTerm="https://www.ncbi.nlm.nih.gov/pubmed/38170210" linkWindow="_blank">https://www.ncbi.nlm.nih.gov/pubmed/38170210</link><br /><link linkTarget="URL" linkTerm="https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&origin=inward&scp=85181248769" linkWindow="_blank">https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&origin=inward&scp=85181248769</link><br /><link linkTarget="URL" linkTerm="https://doi.org/10.1007/s00405-023-08400-3" linkWindow="_blank">https://doi.org/10.1007/s00405-023-08400-3</link>
– Name: Copyright
  Label: Rights
  Group: Cpyrght
  Data: CC BY
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsair.doi.dedup.....68a1e0540839c0c3630f903a8a738184
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsair&AN=edsair.doi.dedup.....68a1e0540839c0c3630f903a8a738184
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00405-023-08400-3
    Languages:
      – Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 2913
    Subjects:
      – SubjectFull: Male
        Type: general
      – SubjectFull: Adult
        Type: general
      – SubjectFull: Hearing preservation
        Type: general
      – SubjectFull: Female [MeSH]
        Type: general
      – SubjectFull: Aged [MeSH]
        Type: general
      – SubjectFull: Adult [MeSH]
        Type: general
      – SubjectFull: Humans [MeSH]
        Type: general
      – SubjectFull: Software [MeSH]
        Type: general
      – SubjectFull: Intraoperative electrocochleography
        Type: general
      – SubjectFull: Middle Aged [MeSH]
        Type: general
      – SubjectFull: Audiometry, Evoked Response/methods [MeSH]
        Type: general
      – SubjectFull: Feasibility Studies [MeSH]
        Type: general
      – SubjectFull: Digital microscope imaging
        Type: general
      – SubjectFull: Otology
        Type: general
      – SubjectFull: Cochlear Implantation/methods [MeSH]
        Type: general
      – SubjectFull: Male [MeSH]
        Type: general
      – SubjectFull: Cochlear implantation
        Type: general
      – SubjectFull: Cochlear Implants [MeSH]
        Type: general
      – SubjectFull: Medizin
        Type: general
      – SubjectFull: Middle Aged
        Type: general
      – SubjectFull: Cochlear Implantation
        Type: general
      – SubjectFull: Audiometry, Evoked Response
        Type: general
      – SubjectFull: Cochlear Implants
        Type: general
      – SubjectFull: Humans
        Type: general
      – SubjectFull: Feasibility Studies
        Type: general
      – SubjectFull: Female
        Type: general
      – SubjectFull: Software
        Type: general
      – SubjectFull: Aged
        Type: general
    Titles:
      – TitleFull: Two different methods to digitally visualize continuous electrocochleography potentials during cochlear implantation: a first description of feasibility
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Theda Eichler
      – PersonEntity:
          Name:
            NameFull: Antonia Lakomek
      – PersonEntity:
          Name:
            NameFull: Laura Waschkies
      – PersonEntity:
          Name:
            NameFull: Moritz Meyer
      – PersonEntity:
          Name:
            NameFull: Nadia Sadok
      – PersonEntity:
          Name:
            NameFull: Stephan Lang
      – PersonEntity:
          Name:
            NameFull: Diana Arweiler-Harbeck
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 03
              M: 01
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 14344726
            – Type: issn-print
              Value: 09374477
            – Type: issn-locals
              Value: edsair
            – Type: issn-locals
              Value: edsairFT
          Numbering:
            – Type: volume
              Value: 281
          Titles:
            – TitleFull: European Archives of Oto-Rhino-Laryngology
              Type: main
ResultId 1