Academic Journal

Об адекватности управления системой промышленного электроснабжения в условиях искажения качества электрической энергии

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Об адекватности управления системой промышленного электроснабжения в условиях искажения качества электрической энергии
Στοιχεία εκδότη: ЗАО "Научно-техническая фирма "Энергопрогресс", 2023.
Έτος έκδοσης: 2023
Θεματικοί όροι: цифровая обработка, векторные измерения, reliability, research, phasor measurements, modeling, надёжность, power quality, ошибка измерения, 7. Clean energy, digital processing, качество электроэнергии, low voltage electrical networks, electrical safety, input multirating switching device, measurement error
Περιγραφή: Networks with a TN–C–S grounding system are the most common in the Russian Federation due to their economic efficiency and a rather high degree of electrical safety. However, the main disadvantage of such networks is the risk of occurring high potential on open conductive parts of electrical equipment in the event of a break in the integrated PEN conductor. On the basis of mathematical modeling and analysis of the processes occurring in TN–C–S networks in the event of a PEN conductor break, the effectiveness of the input multirating switching device which ensures electrical safety in case of indirect contact in the event of such accidents was evaluated. In accordance with the requirements of the regulatory documents on electrical safety, the parameters of the industrial and household electrical devices are determined.
It is noted that the connection to the electrical network of consumers with a non-linear current-voltage characteristic and affecting the quality of electrical energy leads to noise generation not only in the network of an industrial enterprise, but also on the buses of supply substations. The impact of the errors of Phasor Measurement Units (PMU) on the assessment of the parameters of the electrical regime is considered on the example of the simplest power supply system of an industrial enterprise. It is shown that the requirements for the accuracy of Phasor Measurement Units are underestimated in the regulatory documents, especially when the devices are used to control the power supply mode of an industrial load.
Отмечено, что подключение к электрической сети потребителей, имеющих нелинейную вольт-амперную характеристику и влияющих на качество электрической энергии, приводит к возникновению помех не только в сети промышленного предприятия, но и на шинах питающих подстанций. На примере простейшей системы электроснабжения промышленного предприятия рассмотрен вопрос влияния погрешностей устройств синхронизированных векторных измерений (УСВИ) на оценку параметров электрического режима. Указано, что в нормативных документах занижены требования к точности устройств синхронизированных векторных измерений, особенно при использовании их для управления режимом электроснабжения промышленной нагрузки.
Промышленная энергетика, Выпуск 2 2023, Pages 38-46
Τύπος εγγράφου: Article
Γλώσσα: Russian
DOI: 10.34831/ep.2023.92.62.006
Αριθμός Καταχώρησης: edsair.doi...........129eb9d4b9bcc11076dc4d41f3d839d0
Βάση Δεδομένων: OpenAIRE
FullText Text:
  Availability: 0
Header DbId: edsair
DbLabel: OpenAIRE
An: edsair.doi...........129eb9d4b9bcc11076dc4d41f3d839d0
RelevancyScore: 884
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 883.779541015625
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Об адекватности управления системой промышленного электроснабжения в условиях искажения качества электрической энергии
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: ЗАО "Научно-техническая фирма "Энергопрогресс", 2023.
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2023
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22цифровая+обработка%22">цифровая обработка</searchLink><br /><searchLink fieldCode="DE" term="%22векторные+измерения%22">векторные измерения</searchLink><br /><searchLink fieldCode="DE" term="%22reliability%22">reliability</searchLink><br /><searchLink fieldCode="DE" term="%22research%22">research</searchLink><br /><searchLink fieldCode="DE" term="%22phasor+measurements%22">phasor measurements</searchLink><br /><searchLink fieldCode="DE" term="%22modeling%22">modeling</searchLink><br /><searchLink fieldCode="DE" term="%22надёжность%22">надёжность</searchLink><br /><searchLink fieldCode="DE" term="%22power+quality%22">power quality</searchLink><br /><searchLink fieldCode="DE" term="%22ошибка+измерения%22">ошибка измерения</searchLink><br /><searchLink fieldCode="DE" term="%227%2E+Clean+energy%22">7. Clean energy</searchLink><br /><searchLink fieldCode="DE" term="%22digital+processing%22">digital processing</searchLink><br /><searchLink fieldCode="DE" term="%22качество+электроэнергии%22">качество электроэнергии</searchLink><br /><searchLink fieldCode="DE" term="%22low+voltage+electrical+networks%22">low voltage electrical networks</searchLink><br /><searchLink fieldCode="DE" term="%22electrical+safety%22">electrical safety</searchLink><br /><searchLink fieldCode="DE" term="%22input+multirating+switching+device%22">input multirating switching device</searchLink><br /><searchLink fieldCode="DE" term="%22measurement+error%22">measurement error</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: Networks with a TN–C–S grounding system are the most common in the Russian Federation due to their economic efficiency and a rather high degree of electrical safety. However, the main disadvantage of such networks is the risk of occurring high potential on open conductive parts of electrical equipment in the event of a break in the integrated PEN conductor. On the basis of mathematical modeling and analysis of the processes occurring in TN–C–S networks in the event of a PEN conductor break, the effectiveness of the input multirating switching device which ensures electrical safety in case of indirect contact in the event of such accidents was evaluated. In accordance with the requirements of the regulatory documents on electrical safety, the parameters of the industrial and household electrical devices are determined.<br />It is noted that the connection to the electrical network of consumers with a non-linear current-voltage characteristic and affecting the quality of electrical energy leads to noise generation not only in the network of an industrial enterprise, but also on the buses of supply substations. The impact of the errors of Phasor Measurement Units (PMU) on the assessment of the parameters of the electrical regime is considered on the example of the simplest power supply system of an industrial enterprise. It is shown that the requirements for the accuracy of Phasor Measurement Units are underestimated in the regulatory documents, especially when the devices are used to control the power supply mode of an industrial load.<br />Отмечено, что подключение к электрической сети потребителей, имеющих нелинейную вольт-амперную характеристику и влияющих на качество электрической энергии, приводит к возникновению помех не только в сети промышленного предприятия, но и на шинах питающих подстанций. На примере простейшей системы электроснабжения промышленного предприятия рассмотрен вопрос влияния погрешностей устройств синхронизированных векторных измерений (УСВИ) на оценку параметров электрического режима. Указано, что в нормативных документах занижены требования к точности устройств синхронизированных векторных измерений, особенно при использовании их для управления режимом электроснабжения промышленной нагрузки.<br />Промышленная энергетика, Выпуск 2 2023, Pages 38-46
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: Article
– Name: Language
  Label: Language
  Group: Lang
  Data: Russian
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.34831/ep.2023.92.62.006
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsair.doi...........129eb9d4b9bcc11076dc4d41f3d839d0
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsair&AN=edsair.doi...........129eb9d4b9bcc11076dc4d41f3d839d0
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.34831/ep.2023.92.62.006
    Languages:
      – Text: Russian
    Subjects:
      – SubjectFull: цифровая обработка
        Type: general
      – SubjectFull: векторные измерения
        Type: general
      – SubjectFull: reliability
        Type: general
      – SubjectFull: research
        Type: general
      – SubjectFull: phasor measurements
        Type: general
      – SubjectFull: modeling
        Type: general
      – SubjectFull: надёжность
        Type: general
      – SubjectFull: power quality
        Type: general
      – SubjectFull: ошибка измерения
        Type: general
      – SubjectFull: 7. Clean energy
        Type: general
      – SubjectFull: digital processing
        Type: general
      – SubjectFull: качество электроэнергии
        Type: general
      – SubjectFull: low voltage electrical networks
        Type: general
      – SubjectFull: electrical safety
        Type: general
      – SubjectFull: input multirating switching device
        Type: general
      – SubjectFull: measurement error
        Type: general
    Titles:
      – TitleFull: Об адекватности управления системой промышленного электроснабжения в условиях искажения качества электрической энергии
        Type: main
  BibRelationships:
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Type: published
              Y: 2023
          Identifiers:
            – Type: issn-locals
              Value: edsair
ResultId 1