Academic Journal

Экспрессная оценка и оптимизация предела обнаружения в электротермической атомно-абсорбционной спектрометрии

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Экспрессная оценка и оптимизация предела обнаружения в электротермической атомно-абсорбционной спектрометрии
Συγγραφείς: Dyakov, A. O., L'vov, B. V., Novikov, E. V.
Στοιχεία εκδότη: Уральский федеральный университет, 2016.
Έτος έκδοσης: 2016
Θεματικοί όροι: DETECTION LIMIT, PHOTOMETRIC ERROR, АТОМНО-АБСОРБЦИОННАЯ СПЕКТРОМЕТРИЯ С ЭЛЕКТРОТЕРМИЧЕСКОЙ АТОМИЗАЦИЕЙ, ФОТОМЕТРИЧЕСКАЯ ПОГРЕШНОСТЬ, ATOMIC ABSORPTION SPECTROMETRY, ELECTROTHERMAL ATOMIZATION, ПРЕДЕЛ ОБНАРУЖЕНИЯ
Περιγραφή: The functional dependence of the photometric error from the photomultiplier voltage for atomic absorption spectrometer ZEEnit-650 produced by Analytik Jena, has been experimentally studied. This was used to develop, on the base of the algorithm, proposed by these authors previously, a fast semi-empirical method for estimating the detection limits in measuring the integrated absorbance. It was shown that this dependence, determined for one instrument, is acceptable to the whole series of ZEEnit instruments. The proposed approach is also applicable to other types of spectrometers. The functional dependence of the photometric error takes into account the design features of spectrometers. Some other parameters, as the baseline offset compensation time, integration time, light intensity, the background absorbance, and amplitude and integral values of the non-selective absorption, it is easy to evaluate by the use one-three determinations of the analytical signal. This is sufficient for the calculation and optimization of the detection limits of any analytes.
Экспериментально изучена функциональная зависимость фотометрической погрешности атомно-абсорбционного спектрометра ZEEnit-650 фирмы Analytik Jena с графитовым атомизатором от напряжения на фотоумножителе во всем рабочем диапазоне значений. Она использована для проверки корректности быстрого, полуэмпирического способа оценки предела обнаружения интегральной атомной абсорбционности, предложенного авторами ранее. Показано, что такая зависимость, найденная для одного прибора, оказалась приемлемой для всей серии приборов ZEEnit. Предложенный подход применим также к спектрометрам других марок. Предварительно снятая функциональная зависимость фотометрической погрешности учитывает их конструктивные особенности, а остальные параметры, такие как время зануления и интегрирования, амплитудное и интегральное значения неселективной абсорбционности нетрудно определить в ходе одного-трех измерений аналитического сигнала. Этого достаточно для расчета и оптимизации концентрационного и массового пределов обнаружения химических элементов.
Τύπος εγγράφου: Article
Περιγραφή αρχείου: application/pdf
Γλώσσα: Russian
DOI: 10.15826/analitika.2014.18.2.001
Σύνδεσμος πρόσβασης: http://elar.urfu.ru/handle/10995/42688
Αριθμός Καταχώρησης: edsair.dedup.wf.002..c0bd63c93c11a484f32e7647c007835d
Βάση Δεδομένων: OpenAIRE
FullText Text:
  Availability: 0
Header DbId: edsair
DbLabel: OpenAIRE
An: edsair.dedup.wf.002..c0bd63c93c11a484f32e7647c007835d
RelevancyScore: 788
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 787.551513671875
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Экспрессная оценка и оптимизация предела обнаружения в электротермической атомно-абсорбционной спектрометрии
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Dyakov%2C+A%2E+O%2E%22">Dyakov, A. O.</searchLink><br /><searchLink fieldCode="AR" term="%22L'vov%2C+B%2E+V%2E%22">L'vov, B. V.</searchLink><br /><searchLink fieldCode="AR" term="%22Novikov%2C+E%2E+V%2E%22">Novikov, E. V.</searchLink>
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: Уральский федеральный университет, 2016.
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2016
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22DETECTION+LIMIT%22">DETECTION LIMIT</searchLink><br /><searchLink fieldCode="DE" term="%22PHOTOMETRIC+ERROR%22">PHOTOMETRIC ERROR</searchLink><br /><searchLink fieldCode="DE" term="%22АТОМНО-АБСОРБЦИОННАЯ+СПЕКТРОМЕТРИЯ+С+ЭЛЕКТРОТЕРМИЧЕСКОЙ+АТОМИЗАЦИЕЙ%22">АТОМНО-АБСОРБЦИОННАЯ СПЕКТРОМЕТРИЯ С ЭЛЕКТРОТЕРМИЧЕСКОЙ АТОМИЗАЦИЕЙ</searchLink><br /><searchLink fieldCode="DE" term="%22ФОТОМЕТРИЧЕСКАЯ+ПОГРЕШНОСТЬ%22">ФОТОМЕТРИЧЕСКАЯ ПОГРЕШНОСТЬ</searchLink><br /><searchLink fieldCode="DE" term="%22ATOMIC+ABSORPTION+SPECTROMETRY%22">ATOMIC ABSORPTION SPECTROMETRY</searchLink><br /><searchLink fieldCode="DE" term="%22ELECTROTHERMAL+ATOMIZATION%22">ELECTROTHERMAL ATOMIZATION</searchLink><br /><searchLink fieldCode="DE" term="%22ПРЕДЕЛ+ОБНАРУЖЕНИЯ%22">ПРЕДЕЛ ОБНАРУЖЕНИЯ</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: The functional dependence of the photometric error from the photomultiplier voltage for atomic absorption spectrometer ZEEnit-650 produced by Analytik Jena, has been experimentally studied. This was used to develop, on the base of the algorithm, proposed by these authors previously, a fast semi-empirical method for estimating the detection limits in measuring the integrated absorbance. It was shown that this dependence, determined for one instrument, is acceptable to the whole series of ZEEnit instruments. The proposed approach is also applicable to other types of spectrometers. The functional dependence of the photometric error takes into account the design features of spectrometers. Some other parameters, as the baseline offset compensation time, integration time, light intensity, the background absorbance, and amplitude and integral values of the non-selective absorption, it is easy to evaluate by the use one-three determinations of the analytical signal. This is sufficient for the calculation and optimization of the detection limits of any analytes.<br />Экспериментально изучена функциональная зависимость фотометрической погрешности атомно-абсорбционного спектрометра ZEEnit-650 фирмы Analytik Jena с графитовым атомизатором от напряжения на фотоумножителе во всем рабочем диапазоне значений. Она использована для проверки корректности быстрого, полуэмпирического способа оценки предела обнаружения интегральной атомной абсорбционности, предложенного авторами ранее. Показано, что такая зависимость, найденная для одного прибора, оказалась приемлемой для всей серии приборов ZEEnit. Предложенный подход применим также к спектрометрам других марок. Предварительно снятая функциональная зависимость фотометрической погрешности учитывает их конструктивные особенности, а остальные параметры, такие как время зануления и интегрирования, амплитудное и интегральное значения неселективной абсорбционности нетрудно определить в ходе одного-трех измерений аналитического сигнала. Этого достаточно для расчета и оптимизации концентрационного и массового пределов обнаружения химических элементов.
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: Article
– Name: Format
  Label: File Description
  Group: SrcInfo
  Data: application/pdf
– Name: Language
  Label: Language
  Group: Lang
  Data: Russian
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.15826/analitika.2014.18.2.001
– Name: URL
  Label: Access URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="http://elar.urfu.ru/handle/10995/42688" linkWindow="_blank">http://elar.urfu.ru/handle/10995/42688</link>
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsair.dedup.wf.002..c0bd63c93c11a484f32e7647c007835d
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsair&AN=edsair.dedup.wf.002..c0bd63c93c11a484f32e7647c007835d
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.15826/analitika.2014.18.2.001
    Languages:
      – Text: Russian
    Subjects:
      – SubjectFull: DETECTION LIMIT
        Type: general
      – SubjectFull: PHOTOMETRIC ERROR
        Type: general
      – SubjectFull: АТОМНО-АБСОРБЦИОННАЯ СПЕКТРОМЕТРИЯ С ЭЛЕКТРОТЕРМИЧЕСКОЙ АТОМИЗАЦИЕЙ
        Type: general
      – SubjectFull: ФОТОМЕТРИЧЕСКАЯ ПОГРЕШНОСТЬ
        Type: general
      – SubjectFull: ATOMIC ABSORPTION SPECTROMETRY
        Type: general
      – SubjectFull: ELECTROTHERMAL ATOMIZATION
        Type: general
      – SubjectFull: ПРЕДЕЛ ОБНАРУЖЕНИЯ
        Type: general
    Titles:
      – TitleFull: Экспрессная оценка и оптимизация предела обнаружения в электротермической атомно-абсорбционной спектрометрии
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Dyakov, A. O.
      – PersonEntity:
          Name:
            NameFull: L'vov, B. V.
      – PersonEntity:
          Name:
            NameFull: Novikov, E. V.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 20
              M: 11
              Type: published
              Y: 2016
          Identifiers:
            – Type: issn-locals
              Value: edsair
ResultId 1