Academic Journal

Comparison between automated and manual digital diagnostic setups of orthodontic extraction cases: an in silico study.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Comparison between automated and manual digital diagnostic setups of orthodontic extraction cases: an in silico study.
Συγγραφείς: Barbary, Taghrid K., Elkenany, Walid A., Yacout, Yomna M.
Πηγή: Progress in Orthodontics (2196-1042); 2/2/2026, Vol. 27 Issue 1, p1-16, 16p
Θεματικοί όροι: Digital diagnostic imaging, Dental arch, Orthodontic diagnosis, Dental extraction, Medical protocols
Περίληψη: Background: The aim of the study was to evaluate automated digital diagnostic setup in bimaxillary dentoalveolar protrusion cases using two software packages and to compare them to manual digital setup. Methodology: Pre-treatment intraoral scans of 14 patients whose treatment plans involved extraction of four first premolars were imported as Standard Tessellation Language files into dentOne® software (DIORCO co. ltd, Yongin, South Korea) and Ortho Simulation software (MEDIT Corp, Seoul, South Korea). Following tooth segmentation and selection of the teeth to be extracted, an automatic virtual setup was performed in each software. Moreover, manual virtual setups were performed by an orthodontist using dentOne® software. Dental arch changes and dental movements and the duration taken to perform the setups were evaluated and compared using the appropriate statistical tests. Results: The inter-canine, inter-premolar and inter-molar widths did not change significantly following manual virtual setup, while the arch length significantly decreased. The inter-premolar width, inter-molar width and arch length significantly decreased following both automated setups. The manual setup showed significantly greater lingual translation of maxillary and mandibular incisors compared to Ortho Simulation software (mean difference = 5.97 ± 1.10 mm and 7.02 ± 1.29 mm, respectively) and dentOne software (mean difference = 5.73 ± 0.96 mm and 6.95 ± 1.26 mm, respectively). The mesial translation of the maxillary and mandibular molars in Ortho simulation setup (8.35 ± 1.62 mm and 8.69 ± 1.91 mm, respectively) and dentOne setup (7.41 ± 1.28 mm and 7.74 ± 1.90 mm, respectively) was statistically significantly higher than that obtained using the manual setup (− 0.08 ± 0.27 mm, 0.03 ± 0.47 mm, respectively). All setups showed clinically significant lingual inclination of maxillary and mandibular incisors, with the manual setup exhibiting more lingual inclination than both automated setups. Ortho Simulation setup was the fastest method (4.14 ± 0.53 min), followed by dentOne automated setups (7.57 ± 0.94 min), then the manual setup (21.00 ± 1.66 min). Conclusion: Despite being faster, the automated diagnostic setups for bimaxillary protrusion cases constricted the dental arch and did not manage the extraction spaces well, hence, simulating anchorage loss. These findings highlight the need for manual refinement of the automated setups. [ABSTRACT FROM AUTHOR]
Copyright of Progress in Orthodontics (2196-1042) is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Βάση Δεδομένων: Biomedical Index
FullText Links:
  – Type: other
Text:
  Availability: 0
CustomLinks:
  – Url: https://dx.doi.org/doi:10.1186/s40510-026-00605-6
    Name: EDS - Springer Nature Journals (s7799221)
    Category: fullText
    Text: View record at Springer
Header DbId: edm
DbLabel: Biomedical Index
An: 191290833
RelevancyScore: 1041
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 1041.06896972656
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Comparison between automated and manual digital diagnostic setups of orthodontic extraction cases: an in silico study.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Barbary%2C+Taghrid+K%2E%22">Barbary, Taghrid K.</searchLink><br /><searchLink fieldCode="AR" term="%22Elkenany%2C+Walid+A%2E%22">Elkenany, Walid A.</searchLink><br /><searchLink fieldCode="AR" term="%22Yacout%2C+Yomna+M%2E%22">Yacout, Yomna M.</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: Progress in Orthodontics (2196-1042); 2/2/2026, Vol. 27 Issue 1, p1-16, 16p
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Digital+diagnostic+imaging%22">Digital diagnostic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Dental+arch%22">Dental arch</searchLink><br /><searchLink fieldCode="DE" term="%22Orthodontic+diagnosis%22">Orthodontic diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Dental+extraction%22">Dental extraction</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+protocols%22">Medical protocols</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: The aim of the study was to evaluate automated digital diagnostic setup in bimaxillary dentoalveolar protrusion cases using two software packages and to compare them to manual digital setup. Methodology: Pre-treatment intraoral scans of 14 patients whose treatment plans involved extraction of four first premolars were imported as Standard Tessellation Language files into dentOne<superscript>®</superscript> software (DIORCO co. ltd, Yongin, South Korea) and Ortho Simulation software (MEDIT Corp, Seoul, South Korea). Following tooth segmentation and selection of the teeth to be extracted, an automatic virtual setup was performed in each software. Moreover, manual virtual setups were performed by an orthodontist using dentOne<superscript>®</superscript> software. Dental arch changes and dental movements and the duration taken to perform the setups were evaluated and compared using the appropriate statistical tests. Results: The inter-canine, inter-premolar and inter-molar widths did not change significantly following manual virtual setup, while the arch length significantly decreased. The inter-premolar width, inter-molar width and arch length significantly decreased following both automated setups. The manual setup showed significantly greater lingual translation of maxillary and mandibular incisors compared to Ortho Simulation software (mean difference = 5.97 ± 1.10 mm and 7.02 ± 1.29 mm, respectively) and dentOne software (mean difference = 5.73 ± 0.96 mm and 6.95 ± 1.26 mm, respectively). The mesial translation of the maxillary and mandibular molars in Ortho simulation setup (8.35 ± 1.62 mm and 8.69 ± 1.91 mm, respectively) and dentOne setup (7.41 ± 1.28 mm and 7.74 ± 1.90 mm, respectively) was statistically significantly higher than that obtained using the manual setup (− 0.08 ± 0.27 mm, 0.03 ± 0.47 mm, respectively). All setups showed clinically significant lingual inclination of maxillary and mandibular incisors, with the manual setup exhibiting more lingual inclination than both automated setups. Ortho Simulation setup was the fastest method (4.14 ± 0.53 min), followed by dentOne automated setups (7.57 ± 0.94 min), then the manual setup (21.00 ± 1.66 min). Conclusion: Despite being faster, the automated diagnostic setups for bimaxillary protrusion cases constricted the dental arch and did not manage the extraction spaces well, hence, simulating anchorage loss. These findings highlight the need for manual refinement of the automated setups. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label:
  Group: Ab
  Data: <i>Copyright of Progress in Orthodontics (2196-1042) is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edm&AN=191290833
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1186/s40510-026-00605-6
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 16
        StartPage: 1
    Subjects:
      – SubjectFull: Digital diagnostic imaging
        Type: general
      – SubjectFull: Dental arch
        Type: general
      – SubjectFull: Orthodontic diagnosis
        Type: general
      – SubjectFull: Dental extraction
        Type: general
      – SubjectFull: Medical protocols
        Type: general
    Titles:
      – TitleFull: Comparison between automated and manual digital diagnostic setups of orthodontic extraction cases: an in silico study.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Barbary, Taghrid K.
      – PersonEntity:
          Name:
            NameFull: Elkenany, Walid A.
      – PersonEntity:
          Name:
            NameFull: Yacout, Yomna M.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 02
              M: 02
              Text: 2/2/2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 21961042
          Numbering:
            – Type: volume
              Value: 27
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Progress in Orthodontics (2196-1042)
              Type: main
ResultId 1