Academic Journal

A test strip for the estimation of urea in serum.

Bibliographic Details
Title: A test strip for the estimation of urea in serum.
Authors: Kumar, Hemant, Kumar, Ashok, Kumari, Poonam, Tulsani, N.
Source: Indian Journal of Clinical Biochemistry; Jul2000, Vol. 15 Issue 2, p124-127, 4p
Abstract: We have developed a biostrip for determination of urea in serum. The test strip is based on enzymatic assay where urease has been immobilized on the chromatographic paper along with chromogen, phenol red. The chromogen is easily soluble in water and does not require other components for the color change. Serum urea reacts with urease and water to liberate ammonia and carbon dioxide. The liberated ammonia changes the pH of the reaction medium, which is monitored by the chromogen phenol red. A single step working reagent strip has been developed and the reaction is completed within 50 seconds at room temperature. With this test strip urea concentration is measured in serum as low as 0.15 g/L. The speed and convenience of determining urea in serum by this strip instantly makes it well suited for individuals, physicians and emergency centres. [ABSTRACT FROM AUTHOR]
Copyright of Indian Journal of Clinical Biochemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Complementary Index
FullText Links:
  – Type: other
Text:
  Availability: 0
CustomLinks:
  – Url: https://dx.doi.org/doi:10.1007/BF02883740
    Name: EDS - Springer Nature Journals (s7799221)
    Category: fullText
    Text: View record at Springer
Header DbId: edb
DbLabel: Complementary Index
An: 50402348
RelevancyScore: 829
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 828.9541015625
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: A test strip for the estimation of urea in serum.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Kumar%2C+Hemant%22">Kumar, Hemant</searchLink><br /><searchLink fieldCode="AR" term="%22Kumar%2C+Ashok%22">Kumar, Ashok</searchLink><br /><searchLink fieldCode="AR" term="%22Kumari%2C+Poonam%22">Kumari, Poonam</searchLink><br /><searchLink fieldCode="AR" term="%22Tulsani%2C+N%2E%22">Tulsani, N.</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: Indian Journal of Clinical Biochemistry; Jul2000, Vol. 15 Issue 2, p124-127, 4p
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: We have developed a biostrip for determination of urea in serum. The test strip is based on enzymatic assay where urease has been immobilized on the chromatographic paper along with chromogen, phenol red. The chromogen is easily soluble in water and does not require other components for the color change. Serum urea reacts with urease and water to liberate ammonia and carbon dioxide. The liberated ammonia changes the pH of the reaction medium, which is monitored by the chromogen phenol red. A single step working reagent strip has been developed and the reaction is completed within 50 seconds at room temperature. With this test strip urea concentration is measured in serum as low as 0.15 g/L. The speed and convenience of determining urea in serum by this strip instantly makes it well suited for individuals, physicians and emergency centres. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label:
  Group: Ab
  Data: <i>Copyright of Indian Journal of Clinical Biochemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edb&AN=50402348
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/BF02883740
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 4
        StartPage: 124
    Titles:
      – TitleFull: A test strip for the estimation of urea in serum.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Kumar, Hemant
      – PersonEntity:
          Name:
            NameFull: Kumar, Ashok
      – PersonEntity:
          Name:
            NameFull: Kumari, Poonam
      – PersonEntity:
          Name:
            NameFull: Tulsani, N.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 07
              Text: Jul2000
              Type: published
              Y: 2000
          Identifiers:
            – Type: issn-print
              Value: 09701915
          Numbering:
            – Type: volume
              Value: 15
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Indian Journal of Clinical Biochemistry
              Type: main
ResultId 1