Academic Journal
A test strip for the estimation of urea in serum.
| Title: | A test strip for the estimation of urea in serum. |
|---|---|
| Authors: | Kumar, Hemant, Kumar, Ashok, Kumari, Poonam, Tulsani, N. |
| Source: | Indian Journal of Clinical Biochemistry; Jul2000, Vol. 15 Issue 2, p124-127, 4p |
| Abstract: | We have developed a biostrip for determination of urea in serum. The test strip is based on enzymatic assay where urease has been immobilized on the chromatographic paper along with chromogen, phenol red. The chromogen is easily soluble in water and does not require other components for the color change. Serum urea reacts with urease and water to liberate ammonia and carbon dioxide. The liberated ammonia changes the pH of the reaction medium, which is monitored by the chromogen phenol red. A single step working reagent strip has been developed and the reaction is completed within 50 seconds at room temperature. With this test strip urea concentration is measured in serum as low as 0.15 g/L. The speed and convenience of determining urea in serum by this strip instantly makes it well suited for individuals, physicians and emergency centres. [ABSTRACT FROM AUTHOR] |
| Copyright of Indian Journal of Clinical Biochemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Complementary Index |
| FullText | Links: – Type: other Text: Availability: 0 CustomLinks: – Url: https://dx.doi.org/doi:10.1007/BF02883740 Name: EDS - Springer Nature Journals (s7799221) Category: fullText Text: View record at Springer |
|---|---|
| Header | DbId: edb DbLabel: Complementary Index An: 50402348 RelevancyScore: 829 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 828.9541015625 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: A test strip for the estimation of urea in serum. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Kumar%2C+Hemant%22">Kumar, Hemant</searchLink><br /><searchLink fieldCode="AR" term="%22Kumar%2C+Ashok%22">Kumar, Ashok</searchLink><br /><searchLink fieldCode="AR" term="%22Kumari%2C+Poonam%22">Kumari, Poonam</searchLink><br /><searchLink fieldCode="AR" term="%22Tulsani%2C+N%2E%22">Tulsani, N.</searchLink> – Name: TitleSource Label: Source Group: Src Data: Indian Journal of Clinical Biochemistry; Jul2000, Vol. 15 Issue 2, p124-127, 4p – Name: Abstract Label: Abstract Group: Ab Data: We have developed a biostrip for determination of urea in serum. The test strip is based on enzymatic assay where urease has been immobilized on the chromatographic paper along with chromogen, phenol red. The chromogen is easily soluble in water and does not require other components for the color change. Serum urea reacts with urease and water to liberate ammonia and carbon dioxide. The liberated ammonia changes the pH of the reaction medium, which is monitored by the chromogen phenol red. A single step working reagent strip has been developed and the reaction is completed within 50 seconds at room temperature. With this test strip urea concentration is measured in serum as low as 0.15 g/L. The speed and convenience of determining urea in serum by this strip instantly makes it well suited for individuals, physicians and emergency centres. [ABSTRACT FROM AUTHOR] – Name: Abstract Label: Group: Ab Data: <i>Copyright of Indian Journal of Clinical Biochemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edb&AN=50402348 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/BF02883740 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 4 StartPage: 124 Titles: – TitleFull: A test strip for the estimation of urea in serum. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Kumar, Hemant – PersonEntity: Name: NameFull: Kumar, Ashok – PersonEntity: Name: NameFull: Kumari, Poonam – PersonEntity: Name: NameFull: Tulsani, N. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: Jul2000 Type: published Y: 2000 Identifiers: – Type: issn-print Value: 09701915 Numbering: – Type: volume Value: 15 – Type: issue Value: 2 Titles: – TitleFull: Indian Journal of Clinical Biochemistry Type: main |
| ResultId | 1 |