Academic Journal
Pulse width-dependent Monte Carlo source modeling for ultra-high dose rate electron beams.
| Title: | Pulse width-dependent Monte Carlo source modeling for ultra-high dose rate electron beams. |
|---|---|
| Authors: | Henao Isaza Á; Institute of Microelectronics of Barcelona, IMB-CNM (CSIC), Carrer dels Til.lers s/n, 08193, Cerdanyola del Vallés (Bellaterra), Barcelona, Spain., López Paz I; Institute of Microelectronics of Barcelona, IMB-CNM (CSIC), Carrer dels Til.lers s/n, 08193, Cerdanyola del Vallés (Bellaterra), Barcelona, Spain., Guardiola C; Institute of Microelectronics of Barcelona, IMB-CNM (CSIC), Carrer dels Til.lers s/n, 08193, Cerdanyola del Vallés (Bellaterra), Barcelona, Spain., Sebastián Moreno J; Institut Curie, Inserm U1353-CNRS UMR9029, University Versailles Saint-Quentin, PSL Research University, 91405 Orsay, France.; Physics Department, National University of Colombia, Cuidad Universitaria, 11321 Bogotá, Colombia., Heinrich S; Institut Curie, Inserm U1353-CNRS UMR9029, University Versailles Saint-Quentin, PSL Research University, 91405 Orsay, France. |
| Source: | Physics in medicine and biology [Phys Med Biol] 2026 Oct 01; Vol. 71 (19). Date of Electronic Publication: 2026 Oct 01. |
| Publication Type: | Journal Article |
| Language: | English |
| Journal Info: | Publisher: IOP Publishing Country of Publication: England NLM ID: 0401220 Publication Model: Electronic Cited Medium: Internet ISSN: 1361-6560 (Electronic) Linking ISSN: 00319155 NLM ISO Abbreviation: Phys Med Biol Subsets: MEDLINE |
| Imprint Name(s): | Original Publication: Bristol : IOP Publishing |
| MeSH Terms: | Electrons*/therapeutic use , Monte Carlo Method* , Radiation Dosage*, Animals ; Mice ; Radiotherapy Dosage |
| Abstract: | Objective.The emergence of ultra-high dose rate (UHDR) electron beams has highlighted the need for accurate Monte Carlo (MC) source models after recent measurements revealed pulse width (PW)-dependent discrepancies in dose profiles. This work aims to develop and validate a MC source model for conventional and FLASH modes using GATE 10, including PW dependence.Approach.Percentage depth dose (PDD) curves and lateral dose profiles were measured in water using a flashDiamond detector for PWs of 0.5-5s. These data were used to optimize the parametric source model throughminimization and gamma analysis. Validation was performed using a mouse collimator and PMMA slabs. Relative dose distributions and cumulative dose-volume histograms were computed in a CT-based voxelised mouse, with and without bolus.Main results.The optimized FLASH source model features a dual-peak energy spectrum with a PW-dependent energy component (7.0-7.8 MeV for 0.5-5s) and low-energy component probability. In conventional mode, a two-component spectrum (1.51.0 and 6.81.5 MeV) was used. Simulations showed good agreement with measurements (gamma-index 2 mm/2% anddifferences for,and). Differences in the mouse lung volume receiving at least 95% of the maximum dose (V95) were 1% across FLASH PWs, increasing to 5% and 12% in CONV without and with bolus, respectively. Bolus increased V95in FLASH by 17%, indicating improved target coverage.Significance.A GATE 10 MC-based source model of the ElectronFLASH LINAC was developed for both UHDR (PW-dependent) and conventional modes. Despite PW-dependent energy variations, no significant dosimetric differences were observed between PWs in FLASH in the preclinical mouse model. The model provides a reliable tool for optimization of preclinical irradiation setups for FLASH biological studies in the absence of a treatment planning system. (Creative Commons Attribution license.) |
| Contributed Indexing: | Keywords: FLASH electron linac; FLASH-RT; GATE; dosimetry |
| Entry Date(s): | Date Created: 20260916 Date Completed: 20261001 Latest Revision: 20261001 |
| Update Code: | 20261001 |
| DOI: | 10.1088/1361-6560/aea8c4 |
| PMID: | 42748957 |
| Database: | MEDLINE |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42748957 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Pulse width-dependent Monte Carlo source modeling for ultra-high dose rate electron beams. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Henao+Isaza+Á%22">Henao Isaza Á</searchLink>; Institute of Microelectronics of Barcelona, IMB-CNM (CSIC), Carrer dels Til.lers s/n, 08193, Cerdanyola del Vallés (Bellaterra), Barcelona, Spain.<br /><searchLink fieldCode="AU" term="%22López+Paz+I%22">López Paz I</searchLink>; Institute of Microelectronics of Barcelona, IMB-CNM (CSIC), Carrer dels Til.lers s/n, 08193, Cerdanyola del Vallés (Bellaterra), Barcelona, Spain.<br /><searchLink fieldCode="AU" term="%22Guardiola+C%22">Guardiola C</searchLink>; Institute of Microelectronics of Barcelona, IMB-CNM (CSIC), Carrer dels Til.lers s/n, 08193, Cerdanyola del Vallés (Bellaterra), Barcelona, Spain.<br /><searchLink fieldCode="AU" term="%22Sebastián+Moreno+J%22">Sebastián Moreno J</searchLink>; Institut Curie, Inserm U1353-CNRS UMR9029, University Versailles Saint-Quentin, PSL Research University, 91405 Orsay, France.; Physics Department, National University of Colombia, Cuidad Universitaria, 11321 Bogotá, Colombia.<br /><searchLink fieldCode="AU" term="%22Heinrich+S%22">Heinrich S</searchLink>; Institut Curie, Inserm U1353-CNRS UMR9029, University Versailles Saint-Quentin, PSL Research University, 91405 Orsay, France. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%220401220%22">Physics in medicine and biology</searchLink> [Phys Med Biol] 2026 Oct 01; Vol. 71 (19). <i>Date of Electronic Publication: </i>2026 Oct 01. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22IOP+Publishing%22">IOP Publishing </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>0401220 <i>Publication Model: </i>Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1361-6560 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200319155%22">00319155 </searchLink><i>NLM ISO Abbreviation: </i>Phys Med Biol <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Original Publication</i>: Bristol : IOP Publishing – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Electrons%22">Electrons*</searchLink>/<searchLink fieldCode="MM" term="%22Electrons+therapeutic+use%22">therapeutic use</searchLink> <br /><searchLink fieldCode="MM" term="%22Monte+Carlo+Method%22">Monte Carlo Method*</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Dosage%22">Radiation Dosage*</searchLink><br /><searchLink fieldCode="MH" term="%22Animals%22">Animals</searchLink> ; <searchLink fieldCode="MH" term="%22Mice%22">Mice</searchLink> ; <searchLink fieldCode="MH" term="%22Radiotherapy+Dosage%22">Radiotherapy Dosage</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Objective.The emergence of ultra-high dose rate (UHDR) electron beams has highlighted the need for accurate Monte Carlo (MC) source models after recent measurements revealed pulse width (PW)-dependent discrepancies in dose profiles. This work aims to develop and validate a MC source model for conventional and FLASH modes using GATE 10, including PW dependence.Approach.Percentage depth dose (PDD) curves and lateral dose profiles were measured in water using a flashDiamond detector for PWs of 0.5-5s. These data were used to optimize the parametric source model throughminimization and gamma analysis. Validation was performed using a mouse collimator and PMMA slabs. Relative dose distributions and cumulative dose-volume histograms were computed in a CT-based voxelised mouse, with and without bolus.Main results.The optimized FLASH source model features a dual-peak energy spectrum with a PW-dependent energy component (7.0-7.8 MeV for 0.5-5s) and low-energy component probability. In conventional mode, a two-component spectrum (1.51.0 and 6.81.5 MeV) was used. Simulations showed good agreement with measurements (gamma-index 2 mm/2% anddifferences for,and). Differences in the mouse lung volume receiving at least 95% of the maximum dose (V95) were 1% across FLASH PWs, increasing to 5% and 12% in CONV without and with bolus, respectively. Bolus increased V95in FLASH by 17%, indicating improved target coverage.Significance.A GATE 10 MC-based source model of the ElectronFLASH LINAC was developed for both UHDR (PW-dependent) and conventional modes. Despite PW-dependent energy variations, no significant dosimetric differences were observed between PWs in FLASH in the preclinical mouse model. The model provides a reliable tool for optimization of preclinical irradiation setups for FLASH biological studies in the absence of a treatment planning system.<br /> (Creative Commons Attribution license.) – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>FLASH electron linac; FLASH-RT; GATE; dosimetry – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260916 <i>Date Completed: </i>20261001 <i>Latest Revision: </i>20261001 – Name: DateUpdate Label: Update Code Group: Date Data: 20261001 – Name: DOI Label: DOI Group: ID Data: 10.1088/1361-6560/aea8c4 – Name: AN Label: PMID Group: ID Data: 42748957 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42748957 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1088/1361-6560/aea8c4 Languages: – Code: eng Text: English Subjects: – SubjectFull: Animals Type: general – SubjectFull: Mice Type: general – SubjectFull: Radiotherapy Dosage Type: general – SubjectFull: Electrons therapeutic use Type: general – SubjectFull: Monte Carlo Method Type: general – SubjectFull: Radiation Dosage Type: general Titles: – TitleFull: Pulse width-dependent Monte Carlo source modeling for ultra-high dose rate electron beams. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Henao Isaza Á – PersonEntity: Name: NameFull: López Paz I – PersonEntity: Name: NameFull: Guardiola C – PersonEntity: Name: NameFull: Sebastián Moreno J – PersonEntity: Name: NameFull: Heinrich S IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: 2026 Oct 01 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1361-6560 Numbering: – Type: volume Value: 71 – Type: issue Value: 19 Titles: – TitleFull: Physics in medicine and biology Type: main |
| ResultId | 1 |