Academic Journal
Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical192Ir and125I brachytherapy sources.
| Τίτλος: | Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical192Ir and125I brachytherapy sources. |
|---|---|
| Συγγραφείς: | Araújo LF; Department of Nuclear Engineering, School of Engineering, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil., Amin A; Department of Nuclear Engineering, School of Engineering, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil.; School of Pharmacy, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil., Sabino AP; School of Pharmacy, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil., Fonseca TCF; Department of Nuclear Engineering, School of Engineering, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil.; Nuclear Technology Development Center-CDTN, Belo Horizonte, Brazil. |
| Πηγή: | Physics in medicine and biology [Phys Med Biol] 2026 Sep 28; Vol. 71 (19). Date of Electronic Publication: 2026 Sep 28. |
| Τύπος έκδοσης: | Journal Article; Comparative Study |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: IOP Publishing Country of Publication: England NLM ID: 0401220 Publication Model: Electronic Cited Medium: Internet ISSN: 1361-6560 (Electronic) Linking ISSN: 00319155 NLM ISO Abbreviation: Phys Med Biol Subsets: MEDLINE |
| Imprint Name(s): | Original Publication: Bristol : IOP Publishing |
| Ιατρικοί όροι (MeSH): | Brachytherapy*/instrumentation , Iridium Radioisotopes*/therapeutic use , Iodine Radioisotopes*/therapeutic use , Monte Carlo Method*, Radiometry ; Radiotherapy Dosage ; Phantoms, Imaging |
| Περίληψη: | Objective.This study presents a rigorous, simultaneous Monte Carlo (MC) intercomparison of three general-purpose computational codes, MCNP6.2, TOPAS 3.9, and PHITS 3.341, for the calculation and validation of TG-43 dosimetric parameters for the clinical microSelectron-HDR v2Ir and Theragenics-AgX100I brachytherapy sources under realistic, unsimplified photon emission spectra.Approach.Simulations were performed in a spherical liquid water phantom with a radius of 18.5 cm to ensure full-scatter conditions. Dose was scored in small, distance-dependent spherical water scoring cells with varying radii. Discrete, unsimplified photon emission spectra from ICRP Publication 107 were implemented in all three codes. To address gaps in the literature, a computationally efficient simplified geometry previously adopted for theIr source was evaluated, while theI source was modeled with high geometric fidelity. The radial dose and anisotropy functions were calculated, the radial dose data were fitted using fifth-degree polynomials, and the resulting datasets were benchmarked against established TG-43 consensus reference data.Main results.The three MC codes demonstrated good overall agreement. For theIr source, the simplified geometry reproduced the consensus reference data within thecriterion over the clinically relevant radial range, demonstrating its dosimetric suitability within the TG-43 framework. For the low-energyI source, larger deviations, reaching approximately, were observed at short radial distances (cm), consistent with the greater sensitivity of low-energy photon transport to attenuation and shielding effects associated with the source encapsulation and internal components. At distances beyond approximatelycm, the results showed substantially improved agreement, with deviations generally remaining within. Fifth-degree polynomial fitting accurately reproduced the radial dose function, with deviations predominantly remaining below the recommendedcriterion within the clinically relevant radial intervals.Significance.This work establishes a robust, cross-validated computational baseline for brachytherapy dosimetry using general-purpose MC codes under realistic photon emission spectra. The validation of the simplifiedIr geometry supports its use in computationally efficient simulations, while the characterization of the low-energyI source provides relevant information for high-precision dosimetry and future investigations of low-energy radiation interactions in radiosensitization studies. (© 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.) |
| Contributed Indexing: | Keywords: MCNP; Monte Carlo Simulation; PHITS; TG-43; TOPAS; brachytherapy |
| Substance Nomenclature: | 0 (Iridium Radioisotopes) 0 (Iodine Radioisotopes) GVO776611R (Iodine-125) 0 (Iridium-192) |
| Entry Date(s): | Date Created: 20260915 Date Completed: 20260928 Latest Revision: 20260928 |
| Update Code: | 20260928 |
| DOI: | 10.1088/1361-6560/aea7f6 |
| PMID: | 42743978 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42743978 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical192Ir and125I brachytherapy sources. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Araújo+LF%22">Araújo LF</searchLink>; Department of Nuclear Engineering, School of Engineering, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil.<br /><searchLink fieldCode="AU" term="%22Amin+A%22">Amin A</searchLink>; Department of Nuclear Engineering, School of Engineering, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil.; School of Pharmacy, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil.<br /><searchLink fieldCode="AU" term="%22Sabino+AP%22">Sabino AP</searchLink>; School of Pharmacy, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil.<br /><searchLink fieldCode="AU" term="%22Fonseca+TCF%22">Fonseca TCF</searchLink>; Department of Nuclear Engineering, School of Engineering, Federal University of Minas Gerais-UFMG, Belo Horizonte, Brazil.; Nuclear Technology Development Center-CDTN, Belo Horizonte, Brazil. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%220401220%22">Physics in medicine and biology</searchLink> [Phys Med Biol] 2026 Sep 28; Vol. 71 (19). <i>Date of Electronic Publication: </i>2026 Sep 28. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article; Comparative Study – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22IOP+Publishing%22">IOP Publishing </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>0401220 <i>Publication Model: </i>Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1361-6560 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200319155%22">00319155 </searchLink><i>NLM ISO Abbreviation: </i>Phys Med Biol <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Original Publication</i>: Bristol : IOP Publishing – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Brachytherapy%22">Brachytherapy*</searchLink>/<searchLink fieldCode="MM" term="%22Brachytherapy+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Iridium+Radioisotopes%22">Iridium Radioisotopes*</searchLink>/<searchLink fieldCode="MM" term="%22Iridium+Radioisotopes+therapeutic+use%22">therapeutic use</searchLink> <br /><searchLink fieldCode="MM" term="%22Iodine+Radioisotopes%22">Iodine Radioisotopes*</searchLink>/<searchLink fieldCode="MM" term="%22Iodine+Radioisotopes+therapeutic+use%22">therapeutic use</searchLink> <br /><searchLink fieldCode="MM" term="%22Monte+Carlo+Method%22">Monte Carlo Method*</searchLink><br /><searchLink fieldCode="MH" term="%22Radiometry%22">Radiometry</searchLink> ; <searchLink fieldCode="MH" term="%22Radiotherapy+Dosage%22">Radiotherapy Dosage</searchLink> ; <searchLink fieldCode="MH" term="%22Phantoms%2C+Imaging%22">Phantoms, Imaging</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Objective.This study presents a rigorous, simultaneous Monte Carlo (MC) intercomparison of three general-purpose computational codes, MCNP6.2, TOPAS 3.9, and PHITS 3.341, for the calculation and validation of TG-43 dosimetric parameters for the clinical microSelectron-HDR v2Ir and Theragenics-AgX100I brachytherapy sources under realistic, unsimplified photon emission spectra.Approach.Simulations were performed in a spherical liquid water phantom with a radius of 18.5 cm to ensure full-scatter conditions. Dose was scored in small, distance-dependent spherical water scoring cells with varying radii. Discrete, unsimplified photon emission spectra from ICRP Publication 107 were implemented in all three codes. To address gaps in the literature, a computationally efficient simplified geometry previously adopted for theIr source was evaluated, while theI source was modeled with high geometric fidelity. The radial dose and anisotropy functions were calculated, the radial dose data were fitted using fifth-degree polynomials, and the resulting datasets were benchmarked against established TG-43 consensus reference data.Main results.The three MC codes demonstrated good overall agreement. For theIr source, the simplified geometry reproduced the consensus reference data within thecriterion over the clinically relevant radial range, demonstrating its dosimetric suitability within the TG-43 framework. For the low-energyI source, larger deviations, reaching approximately, were observed at short radial distances (cm), consistent with the greater sensitivity of low-energy photon transport to attenuation and shielding effects associated with the source encapsulation and internal components. At distances beyond approximatelycm, the results showed substantially improved agreement, with deviations generally remaining within. Fifth-degree polynomial fitting accurately reproduced the radial dose function, with deviations predominantly remaining below the recommendedcriterion within the clinically relevant radial intervals.Significance.This work establishes a robust, cross-validated computational baseline for brachytherapy dosimetry using general-purpose MC codes under realistic photon emission spectra. The validation of the simplifiedIr geometry supports its use in computationally efficient simulations, while the characterization of the low-energyI source provides relevant information for high-precision dosimetry and future investigations of low-energy radiation interactions in radiosensitization studies.<br /> (© 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.) – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>MCNP; Monte Carlo Simulation; PHITS; TG-43; TOPAS; brachytherapy – Name: NumberCAS Label: Substance Nomenclature Group: ID Data: 0 (Iridium Radioisotopes)<br />0 (Iodine Radioisotopes)<br />GVO776611R (Iodine-125)<br />0 (Iridium-192) – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260915 <i>Date Completed: </i>20260928 <i>Latest Revision: </i>20260928 – Name: DateUpdate Label: Update Code Group: Date Data: 20260928 – Name: DOI Label: DOI Group: ID Data: 10.1088/1361-6560/aea7f6 – Name: AN Label: PMID Group: ID Data: 42743978 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42743978 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1088/1361-6560/aea7f6 Languages: – Code: eng Text: English Subjects: – SubjectFull: Radiometry Type: general – SubjectFull: Radiotherapy Dosage Type: general – SubjectFull: Phantoms, Imaging Type: general – SubjectFull: Brachytherapy instrumentation Type: general – SubjectFull: Iridium Radioisotopes therapeutic use Type: general – SubjectFull: Iodine Radioisotopes therapeutic use Type: general – SubjectFull: Monte Carlo Method Type: general Titles: – TitleFull: Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical192Ir and125I brachytherapy sources. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Araújo LF – PersonEntity: Name: NameFull: Amin A – PersonEntity: Name: NameFull: Sabino AP – PersonEntity: Name: NameFull: Fonseca TCF IsPartOfRelationships: – BibEntity: Dates: – D: 28 M: 09 Text: 2026 Sep 28 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1361-6560 Numbering: – Type: volume Value: 71 – Type: issue Value: 19 Titles: – TitleFull: Physics in medicine and biology Type: main |
| ResultId | 1 |