Academic Journal

Machine Model-Specific Delivery Sequence Optimization for Spot-scanning Proton Arc Therapy Using a Compact Superconducting Synchrocyclotron.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Machine Model-Specific Delivery Sequence Optimization for Spot-scanning Proton Arc Therapy Using a Compact Superconducting Synchrocyclotron.
Συγγραφείς: Liu P; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA.; Department of Medical Physics, School of Medicine, Wayne State University, Detroit, Michigan, USA., Zhao L; Department of Radiation Oncology, Medstar Georgetown University Hospital, Washington, District of Columbia, USA., Cong X; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA., Liu G; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA., Li X; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA., Ding X; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA.
Πηγή: Medical physics [Med Phys] 2026 Sep; Vol. 53 (9), pp. e70658.
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: John Wiley and Sons, Inc Country of Publication: United States NLM ID: 0425746 Publication Model: Print Cited Medium: Internet ISSN: 2473-4209 (Electronic) Linking ISSN: 00942405 NLM ISO Abbreviation: Med Phys Subsets: MEDLINE
Imprint Name(s): Publication: 2017- : Hoboken, NJ : John Wiley and Sons, Inc.
Original Publication: Lancaster, Pa., Published for the American Assn. of Physicists in Medicine by the American Institute of Physics.
Ιατρικοί όροι (MeSH): Proton Therapy*/instrumentation , Proton Therapy*/methods, Radiotherapy Planning, Computer-Assisted/methods ; Brain Neoplasms/radiotherapy ; Radiotherapy Dosage ; Humans
Περίληψη: Background: Spot scanning proton arc therapy (SPArc) combines the dosimetric advantages of proton therapy with the beam-angle freedom of arc delivery. However, current planning algorithms rely on static delivery assumptions that do not account for the temporal characteristics of pulsed-beam synchrocyclotron systems during continuous gantry rotation. This mismatch between nominal plans and actual treatment delivery may lead to clinically meaningful dose deviations.
Purpose: To develop and evaluate a dynamic arc delivery sequencing optimization framework that incorporates machine-specific delivery characteristics to minimize deviations between planned and delivered dose in SPArc.
Methods: A five-step dynamic arc delivery sequencing optimization framework was developed. The framework includes: (1) static and dynamic delivery time calculation, (2) spot and energy-layer disassembling, (3) incorporation of dynamic delivery timing into control points, (4) spot-weight fine-tuning, and (5) reconstruction of energy-layer sequences. Five multi-metastatic brain stereotactic radiosurgery cases were retrospectively evaluated. Delivery accuracy, efficiency and plan quality were assessed using virtual machine logfiles.
Results: The sequencing optimization framework substantially improved delivery accuracy while preserving plan quality and efficiency. For the total gross tumor volume, the mean absolute D98 deviation between planned and virtual logfile reconstructed doses decreased from 77.4 ± 81.0 cGyE (4.2 ± 4.5%) with static SPArc plans to 9.6 ± 4.0 cGyE (0.5 ± 0.2%) after sequencing optimization. For the worst metastasis in each case, D98 deviation decreased from 184.4 ± 145.2 cGyE (9.8 ± 7.9%) to 19.0 ± 16.4 cGyE (1.0 ± 0.8%), and D2 deviation decreased from 148.4 ± 114.4 cGyE (6.8 ± 5.6%) to 13.2 ± 8.6 cGyE (0.6 ± 0.4%). Target coverage and normal brain sparing remained statistically unchanged (p > 0.05), and total delivery times differed by < 1 s.
Conclusions: The proposed sequencing optimization framework addresses the temporal mismatch between static SPArc planning and dynamic delivery in synchrocyclotron-based systems. By improving delivery accuracy without compromising plan quality or delivery efficiency, the framework demonstrates the feasibility of incorporating machine-specific delivery timing into dynamic proton arc therapy.
(© 2026 American Association of Physicists in Medicine.)
References: Int J Radiat Oncol Biol Phys. 2010 Feb 1;76(2):624-30. (PMID: 20117294)
Med Phys. 2023 Mar;50(3):1305-1317. (PMID: 36373893)
J Appl Clin Med Phys. 2012 Mar 08;13(2):3725. (PMID: 22402389)
Front Oncol. 2022 Nov 10;12:1036139. (PMID: 36439480)
Radiat Oncol. 2020 Jan 30;15(1):21. (PMID: 32000817)
Lancet. 2026 Jan 10;407(10524):174-184. (PMID: 41391462)
Int J Radiat Oncol Biol Phys. 2016 Dec 1;96(5):1107-1116. (PMID: 27869083)
J Appl Clin Med Phys. 2024 Sep;25(9):e14486. (PMID: 39137008)
Int J Radiat Oncol Biol Phys. 2013 Dec 1;87(5):871-3. (PMID: 24267966)
Radiat Oncol. 2022 May 7;17(1):87. (PMID: 35525993)
Front Oncol. 2022 May 19;12:804036. (PMID: 35664795)
JAMA Oncol. 2020 Feb 1;6(2):237-246. (PMID: 31876914)
Comput Biol Med. 2022 Sep;148:105609. (PMID: 35803749)
Semin Radiat Oncol. 2013 Apr;23(2):77-87. (PMID: 23473684)
Phys Med. 2024 Oct;126:104816. (PMID: 39326286)
Acta Oncol. 2023 Jan;62(1):48-52. (PMID: 36729848)
Phys Med Biol. 2012 Jun 7;57(11):R99-117. (PMID: 22571913)
Med Dosim. 2024 Spring;49(1):2-12. (PMID: 37996354)
Med Phys. 2026 Sep;53(9):e70658. (PMID: 42670024)
Acta Oncol. 2020 Oct;59(10):1178-1185. (PMID: 32421375)
J Appl Clin Med Phys. 2025 Apr;26(4):e14611. (PMID: 39704661)
Med Phys. 2026 Jan;53(1):e70213. (PMID: 41455058)
Med Phys. 2024 Apr;51(4):3067-3075. (PMID: 38064634)
Grant Information: R01 CA301448 United States CA NCI NIH HHS; R01CA301448 United States CA NCI NIH HHS
Contributed Indexing: Keywords: delivery accuracy; proton arc therapy; synchrocyclotron
Entry Date(s): Date Created: 20260831 Date Completed: 20260831 Latest Revision: 20260926
Update Code: 20260926
PubMed Central ID: PMC13527260
DOI: 10.1002/mp.70658
PMID: 42670024
Βάση Δεδομένων: MEDLINE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=24734209&ISBN=&volume=53&issue=9&date=20260901&spage=e70658&pages=e70658&title=Medical physics&atitle=Machine%20Model-Specific%20Delivery%20Sequence%20Optimization%20for%20Spot-scanning%20Proton%20Arc%20Therapy%20Using%20a%20Compact%20Superconducting%20Synchrocyclotron.&aulast=Liu%20P&id=DOI:10.1002/mp.70658
    Name: Full Text Finder (for New FTF UI) (ns324271)
    Category: fullText
    Text: Full Text Finder
    MouseOverText: Full Text Finder
Header DbId: cmedm
DbLabel: MEDLINE
An: 42670024
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Machine Model-Specific Delivery Sequence Optimization for Spot-scanning Proton Arc Therapy Using a Compact Superconducting Synchrocyclotron.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AU&quot; term=&quot;%22Liu+P%22&quot;&gt;Liu P&lt;/searchLink&gt;; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA.; Department of Medical Physics, School of Medicine, Wayne State University, Detroit, Michigan, USA.&lt;br /&gt;&lt;searchLink fieldCode=&quot;AU&quot; term=&quot;%22Zhao+L%22&quot;&gt;Zhao L&lt;/searchLink&gt;; Department of Radiation Oncology, Medstar Georgetown University Hospital, Washington, District of Columbia, USA.&lt;br /&gt;&lt;searchLink fieldCode=&quot;AU&quot; term=&quot;%22Cong+X%22&quot;&gt;Cong X&lt;/searchLink&gt;; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA.&lt;br /&gt;&lt;searchLink fieldCode=&quot;AU&quot; term=&quot;%22Liu+G%22&quot;&gt;Liu G&lt;/searchLink&gt;; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA.&lt;br /&gt;&lt;searchLink fieldCode=&quot;AU&quot; term=&quot;%22Li+X%22&quot;&gt;Li X&lt;/searchLink&gt;; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA.&lt;br /&gt;&lt;searchLink fieldCode=&quot;AU&quot; term=&quot;%22Ding+X%22&quot;&gt;Ding X&lt;/searchLink&gt;; Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%220425746%22&quot;&gt;Medical physics&lt;/searchLink&gt; [Med Phys] 2026 Sep; Vol. 53 (9), pp. e70658.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: &lt;i&gt;Publisher: &lt;/i&gt;&lt;searchLink fieldCode=&quot;PB&quot; term=&quot;%22John+Wiley+and+Sons%2C+Inc%22&quot;&gt;John Wiley and Sons, Inc &lt;/searchLink&gt;&lt;i&gt;Country of Publication: &lt;/i&gt;United States &lt;i&gt;NLM ID: &lt;/i&gt;0425746 &lt;i&gt;Publication Model: &lt;/i&gt;Print &lt;i&gt;Cited Medium: &lt;/i&gt;Internet &lt;i&gt;ISSN: &lt;/i&gt;2473-4209 (Electronic) &lt;i&gt;Linking ISSN: &lt;/i&gt;&lt;searchLink fieldCode=&quot;IS&quot; term=&quot;%2200942405%22&quot;&gt;00942405 &lt;/searchLink&gt;&lt;i&gt;NLM ISO Abbreviation: &lt;/i&gt;Med Phys &lt;i&gt;Subsets: &lt;/i&gt;MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: &lt;i&gt;Publication&lt;/i&gt;: 2017- : Hoboken, NJ : John Wiley and Sons, Inc.&lt;br /&gt;&lt;i&gt;Original Publication&lt;/i&gt;: Lancaster, Pa., Published for the American Assn. of Physicists in Medicine by the American Institute of Physics.
– Name: SubjectMESH
  Label: MeSH Terms
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Proton+Therapy%22&quot;&gt;Proton Therapy*&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Proton+Therapy+instrumentation%22&quot;&gt;instrumentation&lt;/searchLink&gt; &lt;br /&gt;&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Proton+Therapy%22&quot;&gt;Proton Therapy*&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Proton+Therapy+methods%22&quot;&gt;methods&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Radiotherapy+Planning%2C+Computer-Assisted%22&quot;&gt;Radiotherapy Planning, Computer-Assisted&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Radiotherapy+Planning%2C+Computer-Assisted+methods%22&quot;&gt;methods&lt;/searchLink&gt; ; &lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Brain+Neoplasms%22&quot;&gt;Brain Neoplasms&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Brain+Neoplasms+radiotherapy%22&quot;&gt;radiotherapy&lt;/searchLink&gt; ; &lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Radiotherapy+Dosage%22&quot;&gt;Radiotherapy Dosage&lt;/searchLink&gt; ; &lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Humans%22&quot;&gt;Humans&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Spot scanning proton arc therapy (SPArc) combines the dosimetric advantages of proton therapy with the beam-angle freedom of arc delivery. However, current planning algorithms rely on static delivery assumptions that do not account for the temporal characteristics of pulsed-beam synchrocyclotron systems during continuous gantry rotation. This mismatch between nominal plans and actual treatment delivery may lead to clinically meaningful dose deviations.&lt;br /&gt;Purpose: To develop and evaluate a dynamic arc delivery sequencing optimization framework that incorporates machine-specific delivery characteristics to minimize deviations between planned and delivered dose in SPArc.&lt;br /&gt;Methods: A five-step dynamic arc delivery sequencing optimization framework was developed. The framework includes: (1) static and dynamic delivery time calculation, (2) spot and energy-layer disassembling, (3) incorporation of dynamic delivery timing into control points, (4) spot-weight fine-tuning, and (5) reconstruction of energy-layer sequences. Five multi-metastatic brain stereotactic radiosurgery cases were retrospectively evaluated. Delivery accuracy, efficiency and plan quality were assessed using virtual machine logfiles.&lt;br /&gt;Results: The sequencing optimization framework substantially improved delivery accuracy while preserving plan quality and efficiency. For the total gross tumor volume, the mean absolute D98 deviation between planned and virtual logfile reconstructed doses decreased from 77.4&#160;&#177;&#160;81.0 cGyE (4.2&#160;&#177;&#160;4.5%) with static SPArc plans to 9.6&#160;&#177;&#160;4.0 cGyE (0.5&#160;&#177;&#160;0.2%) after sequencing optimization. For the worst metastasis in each case, D98 deviation decreased from 184.4&#160;&#177;&#160;145.2 cGyE (9.8&#160;&#177;&#160;7.9%) to 19.0&#160;&#177;&#160;16.4 cGyE (1.0&#160;&#177;&#160;0.8%), and D2 deviation decreased from 148.4&#160;&#177;&#160;114.4 cGyE (6.8&#160;&#177;&#160;5.6%) to 13.2&#160;&#177;&#160;8.6 cGyE (0.6&#160;&#177;&#160;0.4%). Target coverage and normal brain sparing remained statistically unchanged (p&#160;&amp;gt;&#160;0.05), and total delivery times differed by&#160;&amp;lt;&#160;1 s.&lt;br /&gt;Conclusions: The proposed sequencing optimization framework addresses the temporal mismatch between static SPArc planning and dynamic delivery in synchrocyclotron-based systems. By improving delivery accuracy without compromising plan quality or delivery efficiency, the framework demonstrates the feasibility of incorporating machine-specific delivery timing into dynamic proton arc therapy.&lt;br /&gt; (&#169; 2026 American Association of Physicists in Medicine.)
– Name: Ref
  Label: References
  Group: RefInfo
  Data: Int J Radiat Oncol Biol Phys. 2010 Feb 1;76(2):624-30. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2220117294%22&quot;&gt;20117294)&lt;/searchLink&gt;&lt;br /&gt;Med Phys. 2023 Mar;50(3):1305-1317. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2236373893%22&quot;&gt;36373893)&lt;/searchLink&gt;&lt;br /&gt;J Appl Clin Med Phys. 2012 Mar 08;13(2):3725. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2222402389%22&quot;&gt;22402389)&lt;/searchLink&gt;&lt;br /&gt;Front Oncol. 2022 Nov 10;12:1036139. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2236439480%22&quot;&gt;36439480)&lt;/searchLink&gt;&lt;br /&gt;Radiat Oncol. 2020 Jan 30;15(1):21. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2232000817%22&quot;&gt;32000817)&lt;/searchLink&gt;&lt;br /&gt;Lancet. 2026 Jan 10;407(10524):174-184. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2241391462%22&quot;&gt;41391462)&lt;/searchLink&gt;&lt;br /&gt;Int J Radiat Oncol Biol Phys. 2016 Dec 1;96(5):1107-1116. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2227869083%22&quot;&gt;27869083)&lt;/searchLink&gt;&lt;br /&gt;J Appl Clin Med Phys. 2024 Sep;25(9):e14486. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2239137008%22&quot;&gt;39137008)&lt;/searchLink&gt;&lt;br /&gt;Int J Radiat Oncol Biol Phys. 2013 Dec 1;87(5):871-3. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2224267966%22&quot;&gt;24267966)&lt;/searchLink&gt;&lt;br /&gt;Radiat Oncol. 2022 May 7;17(1):87. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2235525993%22&quot;&gt;35525993)&lt;/searchLink&gt;&lt;br /&gt;Front Oncol. 2022 May 19;12:804036. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2235664795%22&quot;&gt;35664795)&lt;/searchLink&gt;&lt;br /&gt;JAMA Oncol. 2020 Feb 1;6(2):237-246. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2231876914%22&quot;&gt;31876914)&lt;/searchLink&gt;&lt;br /&gt;Comput Biol Med. 2022 Sep;148:105609. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2235803749%22&quot;&gt;35803749)&lt;/searchLink&gt;&lt;br /&gt;Semin Radiat Oncol. 2013 Apr;23(2):77-87. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2223473684%22&quot;&gt;23473684)&lt;/searchLink&gt;&lt;br /&gt;Phys Med. 2024 Oct;126:104816. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2239326286%22&quot;&gt;39326286)&lt;/searchLink&gt;&lt;br /&gt;Acta Oncol. 2023 Jan;62(1):48-52. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2236729848%22&quot;&gt;36729848)&lt;/searchLink&gt;&lt;br /&gt;Phys Med Biol. 2012 Jun 7;57(11):R99-117. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2222571913%22&quot;&gt;22571913)&lt;/searchLink&gt;&lt;br /&gt;Med Dosim. 2024 Spring;49(1):2-12. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2237996354%22&quot;&gt;37996354)&lt;/searchLink&gt;&lt;br /&gt;Med Phys. 2026 Sep;53(9):e70658. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2242670024%22&quot;&gt;42670024)&lt;/searchLink&gt;&lt;br /&gt;Acta Oncol. 2020 Oct;59(10):1178-1185. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2232421375%22&quot;&gt;32421375)&lt;/searchLink&gt;&lt;br /&gt;J Appl Clin Med Phys. 2025 Apr;26(4):e14611. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2239704661%22&quot;&gt;39704661)&lt;/searchLink&gt;&lt;br /&gt;Med Phys. 2026 Jan;53(1):e70213. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2241455058%22&quot;&gt;41455058)&lt;/searchLink&gt;&lt;br /&gt;Med Phys. 2024 Apr;51(4):3067-3075. (PMID: &lt;searchLink fieldCode=&quot;PM&quot; term=&quot;%2238064634%22&quot;&gt;38064634)&lt;/searchLink&gt;
– Name: GrantInfo
  Label: Grant Information
  Group: Grant
  Data: R01 CA301448 United States CA NCI NIH HHS; R01CA301448 United States CA NCI NIH HHS
– Name: SubjectMinor
  Label: Contributed Indexing
  Group:
  Data: &lt;i&gt;Keywords: &lt;/i&gt;delivery accuracy; proton arc therapy; synchrocyclotron
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: &lt;i&gt;Date Created: &lt;/i&gt;20260831 &lt;i&gt;Date Completed: &lt;/i&gt;20260831 &lt;i&gt;Latest Revision: &lt;/i&gt;20260926
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260926
– Name: PubmedCentralID
  Label: PubMed Central ID
  Group: ID
  Data: PMC13527260
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1002/mp.70658
– Name: AN
  Label: PMID
  Group: ID
  Data: 42670024
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42670024
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.70658
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        StartPage: e70658
    Subjects:
      – SubjectFull: Radiotherapy Planning, Computer-Assisted methods
        Type: general
      – SubjectFull: Brain Neoplasms radiotherapy
        Type: general
      – SubjectFull: Radiotherapy Dosage
        Type: general
      – SubjectFull: Humans
        Type: general
      – SubjectFull: Proton Therapy instrumentation
        Type: general
      – SubjectFull: Proton Therapy methods
        Type: general
    Titles:
      – TitleFull: Machine Model-Specific Delivery Sequence Optimization for Spot-scanning Proton Arc Therapy Using a Compact Superconducting Synchrocyclotron.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Liu P
      – PersonEntity:
          Name:
            NameFull: Zhao L
      – PersonEntity:
          Name:
            NameFull: Cong X
      – PersonEntity:
          Name:
            NameFull: Liu G
      – PersonEntity:
          Name:
            NameFull: Li X
      – PersonEntity:
          Name:
            NameFull: Ding X
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: 2026 Sep
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 2473-4209
          Numbering:
            – Type: volume
              Value: 53
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: Medical physics
              Type: main
ResultId 1