Academic Journal

Microplastics-induced effects on membrane fouling and effluent quality in MBRs for landfill leachate treatment under long-term operation.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Microplastics-induced effects on membrane fouling and effluent quality in MBRs for landfill leachate treatment under long-term operation.
Συγγραφείς: Bian S; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Yan J; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Jiang T; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Li H; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Cai R; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Li W; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Shi J; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Yang F; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Liang S; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Duan H; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Yu W; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China. Electronic address: yuwenbo@hust.edu.cn., Yuan S; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China., Yang J; Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science & Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei 430074, China; Hubei Provincial Engineering Laboratory for Solid Waste Treatment Disposal and Recycling, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; Hubei Provincial Research Center of Water Quality Safety and Water Pollution Control Engineering Technology, Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, China; State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.
Πηγή: Waste management (New York, N.Y.) [Waste Manag] 2026 Oct 30; Vol. 226, pp. 115825. Date of Electronic Publication: 2026 Aug 27.
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Pergamon Press Country of Publication: United States NLM ID: 9884362 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1879-2456 (Electronic) Linking ISSN: 0956053X NLM ISO Abbreviation: Waste Manag Subsets: MEDLINE
Imprint Name(s): Original Publication: New York : Pergamon Press, c1989-
Ιατρικοί όροι (MeSH): Microplastics*/analysis , Water Pollutants, Chemical*/analysis , Waste Disposal, Fluid*/methods , Bioreactors*, Membranes, Artificial ; Waste Disposal Facilities ; Sewage ; Polystyrenes ; Biological Oxygen Demand Analysis ; Biofouling ; Formaldehyde
Περίληψη: Microplastics (MPs) are pervasive in landfill leachate and tend to be retained in membrane bioreactors (MBRs). However, the long-term effects on treatment performance of MBRs remain insufficiently understood. Herein, this study presents a 210-day laboratory experiment comparing a control MBR with two MPs-added MBRs continuously dosed with polystyrene (PS) or phenolic formaldehyde (PF) particles (150-250 µm). Results showed that MPs tended to accumulate in the sludge and settle at the reactor bottom in MBRs, with a small portion incorporated into the membrane cake layer. The final concentrations of MPs in the sludge were 63.1 ± 3.2 mg/L, and 46.4 ± 3.6 mg/L in the PS MPs, and PF MPs groups, respectively. The presence of MPs reduced the removal efficiencies of chemical oxygen demand in the landfill leachate, and intensified membrane fouling. Continuous exposure to MPs stimulated oxidative stress in sludge microorganisms and likely promoted elevated production of extracellular polymeric substances (EPS), thereby forming denser, smoother biofilms with higher organic content on the ultrafiltration membrane surface. By the end of operation, the transmembrane pressure of PS MPs and PF MPs groups were 23.34 kPa, and 33.85 kPa, respectively, which were significantly higher than the Control group (13.17 kPa). Metabolomics analysis further revealed enhancement of pyruvate, citrate cycle metabolism and increased levels of metabolites such as palmitic acid, trehalose and proline. These findings demonstrate that MPs drive metabolic shifts in microbial communities and enhance EPS secretion, leading to persistent membrane fouling in MBRs for landfill leachate treatment.
(Copyright © 2026. Published by Elsevier Ltd.)
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Contributed Indexing: Keywords: Landfillleachate; Membrane bioreactor; Membrane fouling; Microbial metabolomics; Microplastics
Substance Nomenclature: 0 (Microplastics)
0 (Membranes, Artificial)
0 (Water Pollutants, Chemical)
0 (Sewage)
0 (Polystyrenes)
1HG84L3525 (Formaldehyde)
Entry Date(s): Date Created: 20260827 Date Completed: 20260917 Latest Revision: 20260917
Update Code: 20260918
DOI: 10.1016/j.wasman.2026.115825
PMID: 42659855
Βάση Δεδομένων: MEDLINE
Περιγραφή
ISSN:1879-2456
DOI:10.1016/j.wasman.2026.115825