Academic Journal

A three-phase poroelastic-scattering model for skull ultrasound transmission and effective porosity inversion.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: A three-phase poroelastic-scattering model for skull ultrasound transmission and effective porosity inversion.
Συγγραφείς: Gao L; The Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.; University of Chinese Academy of Sciences, Beijing 101408, People's Republic of China.; Shenzhen Key Laboratory of Ultrasound Imaging and Therapy, State Key Laboratory of Biomedical Imaging Science and System, Shenzhen 518055, People's Republic of China., Pan Y; The Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.; University of Chinese Academy of Sciences, Beijing 101408, People's Republic of China.; Shenzhen Key Laboratory of Ultrasound Imaging and Therapy, State Key Laboratory of Biomedical Imaging Science and System, Shenzhen 518055, People's Republic of China., Zhang Z; The Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.; University of Chinese Academy of Sciences, Beijing 101408, People's Republic of China.; Shenzhen Key Laboratory of Ultrasound Imaging and Therapy, State Key Laboratory of Biomedical Imaging Science and System, Shenzhen 518055, People's Republic of China., Qiu W; The Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.; University of Chinese Academy of Sciences, Beijing 101408, People's Republic of China.; Shenzhen Key Laboratory of Ultrasound Imaging and Therapy, State Key Laboratory of Biomedical Imaging Science and System, Shenzhen 518055, People's Republic of China.
Πηγή: Physics in medicine and biology [Phys Med Biol] 2026 Sep 02; Vol. 71 (17). Date of Electronic Publication: 2026 Sep 02.
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: IOP Publishing Country of Publication: England NLM ID: 0401220 Publication Model: Electronic Cited Medium: Internet ISSN: 1361-6560 (Electronic) Linking ISSN: 00319155 NLM ISO Abbreviation: Phys Med Biol Subsets: MEDLINE
Imprint Name(s): Original Publication: Bristol : IOP Publishing
Ιατρικοί όροι (MeSH): Skull*/diagnostic imaging , Elasticity* , Ultrasonic Waves* , Scattering, Radiation* , Models, Biological*, Porosity ; Animals ; Phantoms, Imaging
Περίληψη: Transcranial ultrasound is increasingly used in brain imaging, neuromodulation, and therapy guidance, but its performance is severely degraded by the skull, whose porous and heterogeneous microstructure induces strong attenuation, scattering, and phase distortion in the MHz range. However, skull-induced transmission loss is still commonly handled empirically, and its quantitative relationship to interpretable microstructural descriptors remains poorly established. In this work, we develop a three-phase poroelastic-scattering model for porous cranial bone , comprising a mineralized matrix, a trabecular/cellular solid component within the pore space, and pore fluid. The model combines a Bruggeman-type effective-medium formulation for elastic properties, Biot-Johnson-Koplik-Dashen dynamic viscous coupling, and a Rayleigh-type scattering term to describe frequency-dependent transmission loss. Numerical analysis shows that the fast compressional mode exhibits a characteristic dependence on frequency and porosity, with attenuation governed jointly by viscous/tortuosity losses and microstructural scattering, while phase velocity is dominated by effective stiffness. The model was calibrated using through-transmission measurements on 3D-printed porous epoxy-alumina phantoms with porosities ranging from 10% to 40%, and was subsequently applied toex vivorat and monkey skulls to estimate local effective porosity from the apparent attenuation evaluated at representative analysis frequencies. For the monkey skull, the ultrasound-derived estimates were consistent with the CT-derived apparent porosity obtained from the same specimen. These results support a microstructure-informed parameterization of skull transmission loss and provide a quantitative basis for skull-aware propagation modeling and compensation in transcranial ultrasound.
(© 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.)
Contributed Indexing: Keywords: biot poroelastic theory; effective porosity inversion; poroelastic scattering model; skull attenuation; transcranial ultrasound
Entry Date(s): Date Created: 20260820 Date Completed: 20260902 Latest Revision: 20260902
Update Code: 20260902
DOI: 10.1088/1361-6560/ae9c87
PMID: 42624163
Βάση Δεδομένων: MEDLINE
FullText Text:
  Availability: 0
Header DbId: cmedm
DbLabel: MEDLINE
An: 42624163
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: A three-phase poroelastic-scattering model for skull ultrasound transmission and effective porosity inversion.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Gao+L%22">Gao L</searchLink>; The Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.; University of Chinese Academy of Sciences, Beijing 101408, People's Republic of China.; Shenzhen Key Laboratory of Ultrasound Imaging and Therapy, State Key Laboratory of Biomedical Imaging Science and System, Shenzhen 518055, People's Republic of China.<br /><searchLink fieldCode="AU" term="%22Pan+Y%22">Pan Y</searchLink>; The Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.; University of Chinese Academy of Sciences, Beijing 101408, People's Republic of China.; Shenzhen Key Laboratory of Ultrasound Imaging and Therapy, State Key Laboratory of Biomedical Imaging Science and System, Shenzhen 518055, People's Republic of China.<br /><searchLink fieldCode="AU" term="%22Zhang+Z%22">Zhang Z</searchLink>; The Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.; University of Chinese Academy of Sciences, Beijing 101408, People's Republic of China.; Shenzhen Key Laboratory of Ultrasound Imaging and Therapy, State Key Laboratory of Biomedical Imaging Science and System, Shenzhen 518055, People's Republic of China.<br /><searchLink fieldCode="AU" term="%22Qiu+W%22">Qiu W</searchLink>; The Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.; University of Chinese Academy of Sciences, Beijing 101408, People's Republic of China.; Shenzhen Key Laboratory of Ultrasound Imaging and Therapy, State Key Laboratory of Biomedical Imaging Science and System, Shenzhen 518055, People's Republic of China.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%220401220%22">Physics in medicine and biology</searchLink> [Phys Med Biol] 2026 Sep 02; Vol. 71 (17). <i>Date of Electronic Publication: </i>2026 Sep 02.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22IOP+Publishing%22">IOP Publishing </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>0401220 <i>Publication Model: </i>Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1361-6560 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200319155%22">00319155 </searchLink><i>NLM ISO Abbreviation: </i>Phys Med Biol <i>Subsets: </i>MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: <i>Original Publication</i>: Bristol : IOP Publishing
– Name: SubjectMESH
  Label: MeSH Terms
  Group: Su
  Data: <searchLink fieldCode="MM" term="%22Skull%22">Skull*</searchLink>/<searchLink fieldCode="MM" term="%22Skull+diagnostic+imaging%22">diagnostic imaging</searchLink> <br /><searchLink fieldCode="MM" term="%22Elasticity%22">Elasticity*</searchLink> <br /><searchLink fieldCode="MM" term="%22Ultrasonic+Waves%22">Ultrasonic Waves*</searchLink> <br /><searchLink fieldCode="MM" term="%22Scattering%2C+Radiation%22">Scattering, Radiation*</searchLink> <br /><searchLink fieldCode="MM" term="%22Models%2C+Biological%22">Models, Biological*</searchLink><br /><searchLink fieldCode="MH" term="%22Porosity%22">Porosity</searchLink> ; <searchLink fieldCode="MH" term="%22Animals%22">Animals</searchLink> ; <searchLink fieldCode="MH" term="%22Phantoms%2C+Imaging%22">Phantoms, Imaging</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Transcranial ultrasound is increasingly used in brain imaging, neuromodulation, and therapy guidance, but its performance is severely degraded by the skull, whose porous and heterogeneous microstructure induces strong attenuation, scattering, and phase distortion in the MHz range. However, skull-induced transmission loss is still commonly handled empirically, and its quantitative relationship to interpretable microstructural descriptors remains poorly established. In this work, we develop a three-phase poroelastic-scattering model for porous cranial bone , comprising a mineralized matrix, a trabecular/cellular solid component within the pore space, and pore fluid. The model combines a Bruggeman-type effective-medium formulation for elastic properties, Biot-Johnson-Koplik-Dashen dynamic viscous coupling, and a Rayleigh-type scattering term to describe frequency-dependent transmission loss. Numerical analysis shows that the fast compressional mode exhibits a characteristic dependence on frequency and porosity, with attenuation governed jointly by viscous/tortuosity losses and microstructural scattering, while phase velocity is dominated by effective stiffness. The model was calibrated using through-transmission measurements on 3D-printed porous epoxy-alumina phantoms with porosities ranging from 10% to 40%, and was subsequently applied toex vivorat and monkey skulls to estimate local effective porosity from the apparent attenuation evaluated at representative analysis frequencies. For the monkey skull, the ultrasound-derived estimates were consistent with the CT-derived apparent porosity obtained from the same specimen. These results support a microstructure-informed parameterization of skull transmission loss and provide a quantitative basis for skull-aware propagation modeling and compensation in transcranial ultrasound.<br /> (© 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.)
– Name: SubjectMinor
  Label: Contributed Indexing
  Group:
  Data: <i>Keywords: </i>biot poroelastic theory; effective porosity inversion; poroelastic scattering model; skull attenuation; transcranial ultrasound
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: <i>Date Created: </i>20260820 <i>Date Completed: </i>20260902 <i>Latest Revision: </i>20260902
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260902
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1088/1361-6560/ae9c87
– Name: AN
  Label: PMID
  Group: ID
  Data: 42624163
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42624163
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1088/1361-6560/ae9c87
    Languages:
      – Code: eng
        Text: English
    Subjects:
      – SubjectFull: Porosity
        Type: general
      – SubjectFull: Animals
        Type: general
      – SubjectFull: Phantoms, Imaging
        Type: general
      – SubjectFull: Skull diagnostic imaging
        Type: general
      – SubjectFull: Elasticity
        Type: general
      – SubjectFull: Ultrasonic Waves
        Type: general
      – SubjectFull: Scattering, Radiation
        Type: general
      – SubjectFull: Models, Biological
        Type: general
    Titles:
      – TitleFull: A three-phase poroelastic-scattering model for skull ultrasound transmission and effective porosity inversion.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Gao L
      – PersonEntity:
          Name:
            NameFull: Pan Y
      – PersonEntity:
          Name:
            NameFull: Zhang Z
      – PersonEntity:
          Name:
            NameFull: Qiu W
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 02
              M: 09
              Text: 2026 Sep 02
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 1361-6560
          Numbering:
            – Type: volume
              Value: 71
            – Type: issue
              Value: 17
          Titles:
            – TitleFull: Physics in medicine and biology
              Type: main
ResultId 1