Impact of millimeter-scale target motion on the precision of spatially fractionated radiation therapy using proton minibeams.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Impact of millimeter-scale target motion on the precision of spatially fractionated radiation therapy using proton minibeams.
Συγγραφείς: Actis O; Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Aargau, Switzerland., Fernandez-Palomo C; Institute of Anatomy, University of Bern, Bern, Switzerland., Trappetti V; Institute of Anatomy, University of Bern, Bern, Switzerland., Togno M; Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Aargau, Switzerland., Pellicioli P; Institute of Anatomy, University of Bern, Bern, Switzerland., Leiser D; Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Aargau, Switzerland., Meer D; Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Aargau, Switzerland., Djonov V; Institute of Anatomy, University of Bern, Bern, Switzerland.
Πηγή: Medical physics [Med Phys] 2026 Sep; Vol. 53 (9), pp. e70638.
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: John Wiley and Sons, Inc Country of Publication: United States NLM ID: 0425746 Publication Model: Print Cited Medium: Internet ISSN: 2473-4209 (Electronic) Linking ISSN: 00942405 NLM ISO Abbreviation: Med Phys Subsets: MEDLINE
Imprint Name(s): Publication: 2017- : Hoboken, NJ : John Wiley and Sons, Inc.
Original Publication: Lancaster, Pa., Published for the American Assn. of Physicists in Medicine by the American Institute of Physics.
Ιατρικοί όροι (MeSH): Proton Therapy*/instrumentation , Proton Therapy*/methods , Dose Fractionation, Radiation*, Chorioallantoic Membrane/radiation effects ; Animals ; Chick Embryo ; Movement
Περίληψη: Background: While pencil beam scanning (PBS) with motion mitigation such as re-scanning, breath hold, or gating is well established for treating moving targets in clinical practice, the precision for Spatially Fractionated Radiation Therapy (SFRT) using proton minibeams introduces presents a unique challenge. The sub-millimeter precision required for SFRT cannot be achieved with typical PBS spot sizes (millimeters), necessitating multi-slit beam collimation, which reduces the dose rate and reintroduces motion as a critical issue. In this study, we report on our experience with minibeam irradiations of chorioallantoic membranes (CAM) of chick embryos and discuss potential solutions to the motion problem.
Methods: The first experiment was conducted at a PBS gantry using 130 MeV protons and a 6 cm thick copper multi-slit collimator with 0.3 mm wide slits and 1 mm spacing. To achieve a target peak dose of 30 Gy, CAM samples were irradiated with more than 10 re-scans. Due to a 91% beam loss in the collimator, the total irradiation time extended to two min.
Results: Post-irradiation analysis using gafchromic film revealed smearing of the minibeam profiles, while biological tissue analysis uncovered unexpected and disrupted dose effects, likely caused by irregular CAM movement during irradiation. A subsequent experiment, incorporating additional setup optimizations such as reduced air gap and increased dose rate, shortened the irradiation time to below one min. This led to sharper dose profiles with negligible variation in valley dose and peak width, although a reduction in peak dose of 8%-13% was still observed. This variation is considered acceptable for our biological experiments.
Conclusions: For clinical applications, minibeam re-scanning is likely to be feasible only under ultra-high dose rate conditions (e.g., those required to induce the FLASH effect), where sufficiently short irradiation times minimize motion-induced dose degradation.
(© 2026 The Author(s). Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.)
References: Anat Rec. 2001 Dec 1;264(4):317-24. (PMID: 11745087)
Phys Med Biol. 2017 Mar 7;62(5):1661-1675. (PMID: 28166055)
Med Phys. 2018 Jul 15;:. (PMID: 30009481)
Med Phys. 2012 Nov;39(11):6818-37. (PMID: 23127075)
Br J Radiol. 2019 Mar;92(1095):20180466. (PMID: 30359081)
Sci Rep. 2018 Nov 7;8(1):16479. (PMID: 30405188)
Int J Radiat Oncol Biol Phys. 2019 Jun 1;104(2):266-271. (PMID: 30703513)
Sci Rep. 2020 Jul 9;10(1):11368. (PMID: 32647361)
Int J Radiat Oncol Biol Phys. 2024 Oct 1;120(2):579-592. (PMID: 38621606)
Int J Radiat Oncol Biol Phys. 2016 May 1;95(1):234-241. (PMID: 26692028)
Cancers (Basel). 2021 Dec 22;14(1):. (PMID: 35008189)
Clin Transl Radiat Oncol. 2025 Feb 19;52:100932. (PMID: 40124645)
Contributed Indexing: Keywords: beam delivery; minibeams; proton therapy
Entry Date(s): Date Created: 20260819 Date Completed: 20260819 Latest Revision: 20260822
Update Code: 20260822
PubMed Central ID: PMC13486916
DOI: 10.1002/mp.70638
PMID: 42613851
Βάση Δεδομένων: MEDLINE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=24734209&ISBN=&volume=53&issue=9&date=20260901&spage=e70638&pages=e70638&title=Medical physics&atitle=Impact%20of%20millimeter-scale%20target%20motion%20on%20the%20precision%20of%20spatially%20fractionated%20radiation%20therapy%20using%20proton%20minibeams.&aulast=Actis%20O&id=DOI:10.1002/mp.70638
    Name: Full Text Finder (for New FTF UI) (ns324271)
    Category: fullText
    Text: Full Text Finder
    MouseOverText: Full Text Finder
Header DbId: cmedm
DbLabel: MEDLINE
An: 42613851
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Impact of millimeter-scale target motion on the precision of spatially fractionated radiation therapy using proton minibeams.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Actis+O%22">Actis O</searchLink>; Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Aargau, Switzerland.<br /><searchLink fieldCode="AU" term="%22Fernandez-Palomo+C%22">Fernandez-Palomo C</searchLink>; Institute of Anatomy, University of Bern, Bern, Switzerland.<br /><searchLink fieldCode="AU" term="%22Trappetti+V%22">Trappetti V</searchLink>; Institute of Anatomy, University of Bern, Bern, Switzerland.<br /><searchLink fieldCode="AU" term="%22Togno+M%22">Togno M</searchLink>; Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Aargau, Switzerland.<br /><searchLink fieldCode="AU" term="%22Pellicioli+P%22">Pellicioli P</searchLink>; Institute of Anatomy, University of Bern, Bern, Switzerland.<br /><searchLink fieldCode="AU" term="%22Leiser+D%22">Leiser D</searchLink>; Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Aargau, Switzerland.<br /><searchLink fieldCode="AU" term="%22Meer+D%22">Meer D</searchLink>; Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Aargau, Switzerland.<br /><searchLink fieldCode="AU" term="%22Djonov+V%22">Djonov V</searchLink>; Institute of Anatomy, University of Bern, Bern, Switzerland.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%220425746%22">Medical physics</searchLink> [Med Phys] 2026 Sep; Vol. 53 (9), pp. e70638.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22John+Wiley+and+Sons%2C+Inc%22">John Wiley and Sons, Inc </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>0425746 <i>Publication Model: </i>Print <i>Cited Medium: </i>Internet <i>ISSN: </i>2473-4209 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200942405%22">00942405 </searchLink><i>NLM ISO Abbreviation: </i>Med Phys <i>Subsets: </i>MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: <i>Publication</i>: 2017- : Hoboken, NJ : John Wiley and Sons, Inc.<br /><i>Original Publication</i>: Lancaster, Pa., Published for the American Assn. of Physicists in Medicine by the American Institute of Physics.
– Name: SubjectMESH
  Label: MeSH Terms
  Group: Su
  Data: <searchLink fieldCode="MM" term="%22Proton+Therapy%22">Proton Therapy*</searchLink>/<searchLink fieldCode="MM" term="%22Proton+Therapy+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Proton+Therapy%22">Proton Therapy*</searchLink>/<searchLink fieldCode="MM" term="%22Proton+Therapy+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Dose+Fractionation%2C+Radiation%22">Dose Fractionation, Radiation*</searchLink><br /><searchLink fieldCode="MH" term="%22Chorioallantoic+Membrane%22">Chorioallantoic Membrane</searchLink>/<searchLink fieldCode="MH" term="%22Chorioallantoic+Membrane+radiation+effects%22">radiation effects</searchLink> ; <searchLink fieldCode="MH" term="%22Animals%22">Animals</searchLink> ; <searchLink fieldCode="MH" term="%22Chick+Embryo%22">Chick Embryo</searchLink> ; <searchLink fieldCode="MH" term="%22Movement%22">Movement</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: While pencil beam scanning (PBS) with motion mitigation such as re-scanning, breath hold, or gating is well established for treating moving targets in clinical practice, the precision for Spatially Fractionated Radiation Therapy (SFRT) using proton minibeams introduces presents a unique challenge. The sub-millimeter precision required for SFRT cannot be achieved with typical PBS spot sizes (millimeters), necessitating multi-slit beam collimation, which reduces the dose rate and reintroduces motion as a critical issue. In this study, we report on our experience with minibeam irradiations of chorioallantoic membranes (CAM) of chick embryos and discuss potential solutions to the motion problem.<br />Methods: The first experiment was conducted at a PBS gantry using 130 MeV protons and a 6 cm thick copper multi-slit collimator with 0.3 mm wide slits and 1 mm spacing. To achieve a target peak dose of 30 Gy, CAM samples were irradiated with more than 10 re-scans. Due to a 91% beam loss in the collimator, the total irradiation time extended to two min.<br />Results: Post-irradiation analysis using gafchromic film revealed smearing of the minibeam profiles, while biological tissue analysis uncovered unexpected and disrupted dose effects, likely caused by irregular CAM movement during irradiation. A subsequent experiment, incorporating additional setup optimizations such as reduced air gap and increased dose rate, shortened the irradiation time to below one min. This led to sharper dose profiles with negligible variation in valley dose and peak width, although a reduction in peak dose of 8%-13% was still observed. This variation is considered acceptable for our biological experiments.<br />Conclusions: For clinical applications, minibeam re-scanning is likely to be feasible only under ultra-high dose rate conditions (e.g., those required to induce the FLASH effect), where sufficiently short irradiation times minimize motion-induced dose degradation.<br /> (© 2026 The Author(s). Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.)
– Name: Ref
  Label: References
  Group: RefInfo
  Data: Anat Rec. 2001 Dec 1;264(4):317-24. (PMID: <searchLink fieldCode="PM" term="%2211745087%22">11745087)</searchLink><br />Phys Med Biol. 2017 Mar 7;62(5):1661-1675. (PMID: <searchLink fieldCode="PM" term="%2228166055%22">28166055)</searchLink><br />Med Phys. 2018 Jul 15;:. (PMID: <searchLink fieldCode="PM" term="%2230009481%22">30009481)</searchLink><br />Med Phys. 2012 Nov;39(11):6818-37. (PMID: <searchLink fieldCode="PM" term="%2223127075%22">23127075)</searchLink><br />Br J Radiol. 2019 Mar;92(1095):20180466. (PMID: <searchLink fieldCode="PM" term="%2230359081%22">30359081)</searchLink><br />Sci Rep. 2018 Nov 7;8(1):16479. (PMID: <searchLink fieldCode="PM" term="%2230405188%22">30405188)</searchLink><br />Int J Radiat Oncol Biol Phys. 2019 Jun 1;104(2):266-271. (PMID: <searchLink fieldCode="PM" term="%2230703513%22">30703513)</searchLink><br />Sci Rep. 2020 Jul 9;10(1):11368. (PMID: <searchLink fieldCode="PM" term="%2232647361%22">32647361)</searchLink><br />Int J Radiat Oncol Biol Phys. 2024 Oct 1;120(2):579-592. (PMID: <searchLink fieldCode="PM" term="%2238621606%22">38621606)</searchLink><br />Int J Radiat Oncol Biol Phys. 2016 May 1;95(1):234-241. (PMID: <searchLink fieldCode="PM" term="%2226692028%22">26692028)</searchLink><br />Cancers (Basel). 2021 Dec 22;14(1):. (PMID: <searchLink fieldCode="PM" term="%2235008189%22">35008189)</searchLink><br />Clin Transl Radiat Oncol. 2025 Feb 19;52:100932. (PMID: <searchLink fieldCode="PM" term="%2240124645%22">40124645)</searchLink>
– Name: SubjectMinor
  Label: Contributed Indexing
  Group:
  Data: <i>Keywords: </i>beam delivery; minibeams; proton therapy
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: <i>Date Created: </i>20260819 <i>Date Completed: </i>20260819 <i>Latest Revision: </i>20260822
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260822
– Name: PubmedCentralID
  Label: PubMed Central ID
  Group: ID
  Data: PMC13486916
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1002/mp.70638
– Name: AN
  Label: PMID
  Group: ID
  Data: 42613851
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42613851
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.70638
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        StartPage: e70638
    Subjects:
      – SubjectFull: Chorioallantoic Membrane radiation effects
        Type: general
      – SubjectFull: Animals
        Type: general
      – SubjectFull: Chick Embryo
        Type: general
      – SubjectFull: Movement
        Type: general
      – SubjectFull: Proton Therapy instrumentation
        Type: general
      – SubjectFull: Proton Therapy methods
        Type: general
      – SubjectFull: Dose Fractionation, Radiation
        Type: general
    Titles:
      – TitleFull: Impact of millimeter-scale target motion on the precision of spatially fractionated radiation therapy using proton minibeams.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Actis O
      – PersonEntity:
          Name:
            NameFull: Fernandez-Palomo C
      – PersonEntity:
          Name:
            NameFull: Trappetti V
      – PersonEntity:
          Name:
            NameFull: Togno M
      – PersonEntity:
          Name:
            NameFull: Pellicioli P
      – PersonEntity:
          Name:
            NameFull: Leiser D
      – PersonEntity:
          Name:
            NameFull: Meer D
      – PersonEntity:
          Name:
            NameFull: Djonov V
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: 2026 Sep
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 2473-4209
          Numbering:
            – Type: volume
              Value: 53
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: Medical physics
              Type: main
ResultId 1