Academic Journal
Accuracy evaluation and acceleration of Monte Carlo simulation of scattered radiation using a high-fidelity mobile X-ray fluoroscopy system model.
| Τίτλος: | Accuracy evaluation and acceleration of Monte Carlo simulation of scattered radiation using a high-fidelity mobile X-ray fluoroscopy system model. |
|---|---|
| Συγγραφείς: | Tabuchi M; Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan., Fujibuchi T; Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. fujibuchi.toshioh.294@m.kyushu-u.ac.jp., Han D; Department of Radiological Sciences, Kangwon National University, Samcheok, Republic of Korea. |
| Πηγή: | Radiological physics and technology [Radiol Phys Technol] 2026 Sep; Vol. 19 (3), pp. 1450-1459. Date of Electronic Publication: 2026 Aug 03. |
| Τύπος έκδοσης: | Journal Article; Evaluation Study |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: Springer Japan Country of Publication: Japan NLM ID: 101467995 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1865-0341 (Electronic) Linking ISSN: 18650333 NLM ISO Abbreviation: Radiol Phys Technol Subsets: MEDLINE |
| Imprint Name(s): | Original Publication: Tokyo : Springer Japan |
| Ιατρικοί όροι (MeSH): | Monte Carlo Method* , Scattering, Radiation*, Fluoroscopy/instrumentation ; Electrons ; Radiation Dosage ; X-Rays |
| Περίληψη: | A high-fidelity electron-source Monte Carlo model of a mobile C-arm fluoroscopy system was developed using Particle and Heavy Ion Transport code system (PHITS) to evaluate scattered radiation and calculation acceleration. Electrons were injected into the X-ray tube target, and energy spectra, dose profiles, and scattered doses around the tube head and in the room were calculated. Simulated spectra Simulated spectra agreed with the measured spectra with a root mean square error of 0.06 or less, and the simulation-to-measurement ratios of the scattered air kerma from the electron-source simulations were within 20% at every measurement point. In the simulated two-dimensional distributions, the electron-source simulations showed higher scattered doses than the photon-source simulation at heights above 150 cm. The time required to reach 10% statistical uncertainty decreased from 168.28 h to 72.33 h using the dump technique and to 1.25 h, excluding the dump-generation stage, when combined with the weight window method. The method supports characterization of scattered air-kerma distributions relevant to occupational exposure. (© 2026. The Author(s), under exclusive licence to Japanese Society of Radiological Technology and Japan Society of Medical Physics.) |
| Competing Interests: | Declarations. Conflict of interest: The authors declare no conflict of interest. Ethical approval: This study did not involve human participants or animals and ethical approval was not required. Informed consent: Informed consent was not required for this study. |
| References: | Radiol Phys Technol. 2026 Mar;19(1):21-44. (PMID: 41627716) Tech Vasc Interv Radiol. 2018 Mar;21(1):37-42. (PMID: 29471999) Phys Med. 2022 Dec;104:123-128. (PMID: 36401940) J Radiat Res. 2020 Sep 8;61(5):691-696. (PMID: 32657327) Med Phys. 2018 Jan;45(1):e1-e5. (PMID: 29178605) Radiology. 2008 Sep;248(3):945-53. (PMID: 18632529) Phys Med. 2020 Jun 5;75:44-54. (PMID: 32512239) Health Phys. 2008 Mar;94(3):211-27. (PMID: 18301095) Radiol Phys Technol. 2024 Mar;17(1):288-296. (PMID: 38316688) Radiol Phys Technol. 2019 Dec;12(4):401-408. (PMID: 31617146) Med Phys. 2021 Jul;48(7):3630-3637. (PMID: 33993511) Phys Med. 2020 Oct;78:58-70. (PMID: 32947085) Med Phys. 2021 Apr;48(4):1956-1966. (PMID: 33544901) Health Phys. 2008 Nov;95(5):638-44. (PMID: 18849697) |
| Contributed Indexing: | Keywords: Heel effect; Monte Carlo simulation; Scattered radiation; Variance reduction technique; X-ray fluoroscopy |
| Entry Date(s): | Date Created: 20260803 Date Completed: 20260905 Latest Revision: 20261008 |
| Update Code: | 20261008 |
| DOI: | 10.1007/s12194-026-01111-4 |
| PMID: | 42545599 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42545599 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Accuracy evaluation and acceleration of Monte Carlo simulation of scattered radiation using a high-fidelity mobile X-ray fluoroscopy system model. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Tabuchi+M%22">Tabuchi M</searchLink>; Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.<br /><searchLink fieldCode="AU" term="%22Fujibuchi+T%22">Fujibuchi T</searchLink>; Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. fujibuchi.toshioh.294@m.kyushu-u.ac.jp.<br /><searchLink fieldCode="AU" term="%22Han+D%22">Han D</searchLink>; Department of Radiological Sciences, Kangwon National University, Samcheok, Republic of Korea. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22101467995%22">Radiological physics and technology</searchLink> [Radiol Phys Technol] 2026 Sep; Vol. 19 (3), pp. 1450-1459. <i>Date of Electronic Publication: </i>2026 Aug 03. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article; Evaluation Study – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Springer+Japan%22">Springer Japan </searchLink><i>Country of Publication: </i>Japan <i>NLM ID: </i>101467995 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1865-0341 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2218650333%22">18650333 </searchLink><i>NLM ISO Abbreviation: </i>Radiol Phys Technol <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Original Publication</i>: Tokyo : Springer Japan – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Monte+Carlo+Method%22">Monte Carlo Method*</searchLink> <br /><searchLink fieldCode="MM" term="%22Scattering%2C+Radiation%22">Scattering, Radiation*</searchLink><br /><searchLink fieldCode="MH" term="%22Fluoroscopy%22">Fluoroscopy</searchLink>/<searchLink fieldCode="MH" term="%22Fluoroscopy+instrumentation%22">instrumentation</searchLink> ; <searchLink fieldCode="MH" term="%22Electrons%22">Electrons</searchLink> ; <searchLink fieldCode="MH" term="%22Radiation+Dosage%22">Radiation Dosage</searchLink> ; <searchLink fieldCode="MH" term="%22X-Rays%22">X-Rays</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: A high-fidelity electron-source Monte Carlo model of a mobile C-arm fluoroscopy system was developed using Particle and Heavy Ion Transport code system (PHITS) to evaluate scattered radiation and calculation acceleration. Electrons were injected into the X-ray tube target, and energy spectra, dose profiles, and scattered doses around the tube head and in the room were calculated. Simulated spectra Simulated spectra agreed with the measured spectra with a root mean square error of 0.06 or less, and the simulation-to-measurement ratios of the scattered air kerma from the electron-source simulations were within 20% at every measurement point. In the simulated two-dimensional distributions, the electron-source simulations showed higher scattered doses than the photon-source simulation at heights above 150 cm. The time required to reach 10% statistical uncertainty decreased from 168.28 h to 72.33 h using the dump technique and to 1.25 h, excluding the dump-generation stage, when combined with the weight window method. The method supports characterization of scattered air-kerma distributions relevant to occupational exposure.<br /> (© 2026. The Author(s), under exclusive licence to Japanese Society of Radiological Technology and Japan Society of Medical Physics.) – Name: Abstract Label: Competing Interests Group: Ab Data: Declarations. Conflict of interest: The authors declare no conflict of interest. Ethical approval: This study did not involve human participants or animals and ethical approval was not required. Informed consent: Informed consent was not required for this study. – Name: Ref Label: References Group: RefInfo Data: Radiol Phys Technol. 2026 Mar;19(1):21-44. (PMID: <searchLink fieldCode="PM" term="%2241627716%22">41627716)</searchLink><br />Tech Vasc Interv Radiol. 2018 Mar;21(1):37-42. (PMID: <searchLink fieldCode="PM" term="%2229471999%22">29471999)</searchLink><br />Phys Med. 2022 Dec;104:123-128. (PMID: <searchLink fieldCode="PM" term="%2236401940%22">36401940)</searchLink><br />J Radiat Res. 2020 Sep 8;61(5):691-696. (PMID: <searchLink fieldCode="PM" term="%2232657327%22">32657327)</searchLink><br />Med Phys. 2018 Jan;45(1):e1-e5. (PMID: <searchLink fieldCode="PM" term="%2229178605%22">29178605)</searchLink><br />Radiology. 2008 Sep;248(3):945-53. (PMID: <searchLink fieldCode="PM" term="%2218632529%22">18632529)</searchLink><br />Phys Med. 2020 Jun 5;75:44-54. (PMID: <searchLink fieldCode="PM" term="%2232512239%22">32512239)</searchLink><br />Health Phys. 2008 Mar;94(3):211-27. (PMID: <searchLink fieldCode="PM" term="%2218301095%22">18301095)</searchLink><br />Radiol Phys Technol. 2024 Mar;17(1):288-296. (PMID: <searchLink fieldCode="PM" term="%2238316688%22">38316688)</searchLink><br />Radiol Phys Technol. 2019 Dec;12(4):401-408. (PMID: <searchLink fieldCode="PM" term="%2231617146%22">31617146)</searchLink><br />Med Phys. 2021 Jul;48(7):3630-3637. (PMID: <searchLink fieldCode="PM" term="%2233993511%22">33993511)</searchLink><br />Phys Med. 2020 Oct;78:58-70. (PMID: <searchLink fieldCode="PM" term="%2232947085%22">32947085)</searchLink><br />Med Phys. 2021 Apr;48(4):1956-1966. (PMID: <searchLink fieldCode="PM" term="%2233544901%22">33544901)</searchLink><br />Health Phys. 2008 Nov;95(5):638-44. (PMID: <searchLink fieldCode="PM" term="%2218849697%22">18849697)</searchLink> – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>Heel effect; Monte Carlo simulation; Scattered radiation; Variance reduction technique; X-ray fluoroscopy – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260803 <i>Date Completed: </i>20260905 <i>Latest Revision: </i>20261008 – Name: DateUpdate Label: Update Code Group: Date Data: 20261008 – Name: DOI Label: DOI Group: ID Data: 10.1007/s12194-026-01111-4 – Name: AN Label: PMID Group: ID Data: 42545599 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42545599 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s12194-026-01111-4 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 1450 Subjects: – SubjectFull: Fluoroscopy instrumentation Type: general – SubjectFull: Electrons Type: general – SubjectFull: Radiation Dosage Type: general – SubjectFull: X-Rays Type: general – SubjectFull: Monte Carlo Method Type: general – SubjectFull: Scattering, Radiation Type: general Titles: – TitleFull: Accuracy evaluation and acceleration of Monte Carlo simulation of scattered radiation using a high-fidelity mobile X-ray fluoroscopy system model. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Tabuchi M – PersonEntity: Name: NameFull: Fujibuchi T – PersonEntity: Name: NameFull: Han D IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 09 Text: 2026 Sep Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1865-0341 Numbering: – Type: volume Value: 19 – Type: issue Value: 3 Titles: – TitleFull: Radiological physics and technology Type: main |
| ResultId | 1 |