Academic Journal
Estimation of backscatter factor in ISO-recommended phantoms for photon beams of different beam sizes using Monte Carlo simulations.
| Title: | Estimation of backscatter factor in ISO-recommended phantoms for photon beams of different beam sizes using Monte Carlo simulations. |
|---|---|
| Authors: | Yadav R; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400085, India., Bakshi AK; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400085, India.; Homi Bhabha National Institute, Mumbai 400085, India., Sapra BK; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400085, India.; Homi Bhabha National Institute, Mumbai 400085, India. |
| Source: | Journal of radiological protection : official journal of the Society for Radiological Protection [J Radiol Prot] 2026 Aug 03; Vol. 46 (3). Date of Electronic Publication: 2026 Aug 03. |
| Publication Type: | Journal Article |
| Language: | English |
| Journal Info: | Publisher: IOP Pub. Ltd Country of Publication: England NLM ID: 8809257 Publication Model: Electronic Cited Medium: Internet ISSN: 1361-6498 (Electronic) Linking ISSN: 09524746 NLM ISO Abbreviation: J Radiol Prot Subsets: MEDLINE |
| Imprint Name(s): | Original Publication: [Bristol, UK] : IOP Pub. Ltd., [c1988- |
| MeSH Terms: | Monte Carlo Method* , Photons* , Scattering, Radiation* , Phantoms, Imaging* , Radiometry*, Computer Simulation ; Radiation Dosage |
| Abstract: | Backscatter factor (BSF) is a critical correction parameter in radiation dosimetry, accounting for dose enhancement due to photon scattering within irradiated media; however, systematic evaluations beyond the ISO slab phantom remain limited. In this work, BSFs were comprehensively estimated for all ISO-recommended phantoms-slab, cylindrical, pillar, and rod-over a photon energy range of 10 keV-2 MeV and multiple field sizes using the FLUKA Monte Carlo code with an air-kerma-based formalism. The results show a strong coupled dependence of BSF on photon energy and beam size, with a characteristic peak in the intermediate energy range (∼40-80 keV) and geometry-driven variations and field-size sensitivity-maximized in the slab phantom and minimized in the rod due to scattering volume constraints, while cylindrical and pillar phantoms exhibit intermediate behaviour. To extend these results to realistic irradiation conditions, a Python-based standalone tool was developed using PCHIP interpolation and fluence-weighted averaging to compute spectrum-averaged BSFs for ISO 4037 beams, diagnostic and therapeutic spectra, and user-defined spectra, demonstrating deviation within 0%-2.3% with published data. The study provides a BSF dataset across all ISO phantoms along with a validated computational framework, enabling improved accuracy in dosimeter calibration and determination of operational quantities such asH (Creative Commons Attribution license.) |
| Contributed Indexing: | Keywords: Backscatter factor; ISO recommended phantoms; ISO slab phantom; backscatter factor beam size; photon back scattering factor |
| Entry Date(s): | Date Created: 20260722 Date Completed: 20260803 Latest Revision: 20260803 |
| Update Code: | 20260803 |
| DOI: | 10.1088/1361-6498/ae8e83 |
| PMID: | 42486140 |
| Database: | MEDLINE |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42486140 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Estimation of backscatter factor in ISO-recommended phantoms for photon beams of different beam sizes using Monte Carlo simulations. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Yadav+R%22">Yadav R</searchLink>; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400085, India.<br /><searchLink fieldCode="AU" term="%22Bakshi+AK%22">Bakshi AK</searchLink>; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400085, India.; Homi Bhabha National Institute, Mumbai 400085, India.<br /><searchLink fieldCode="AU" term="%22Sapra+BK%22">Sapra BK</searchLink>; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400085, India.; Homi Bhabha National Institute, Mumbai 400085, India. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%228809257%22">Journal of radiological protection : official journal of the Society for Radiological Protection</searchLink> [J Radiol Prot] 2026 Aug 03; Vol. 46 (3). <i>Date of Electronic Publication: </i>2026 Aug 03. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22IOP+Pub%2E+Ltd%22">IOP Pub. Ltd </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>8809257 <i>Publication Model: </i>Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1361-6498 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2209524746%22">09524746 </searchLink><i>NLM ISO Abbreviation: </i>J Radiol Prot <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Original Publication</i>: [Bristol, UK] : IOP Pub. Ltd., [c1988- – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Monte+Carlo+Method%22">Monte Carlo Method*</searchLink> <br /><searchLink fieldCode="MM" term="%22Photons%22">Photons*</searchLink> <br /><searchLink fieldCode="MM" term="%22Scattering%2C+Radiation%22">Scattering, Radiation*</searchLink> <br /><searchLink fieldCode="MM" term="%22Phantoms%2C+Imaging%22">Phantoms, Imaging*</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiometry%22">Radiometry*</searchLink><br /><searchLink fieldCode="MH" term="%22Computer+Simulation%22">Computer Simulation</searchLink> ; <searchLink fieldCode="MH" term="%22Radiation+Dosage%22">Radiation Dosage</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Backscatter factor (BSF) is a critical correction parameter in radiation dosimetry, accounting for dose enhancement due to photon scattering within irradiated media; however, systematic evaluations beyond the ISO slab phantom remain limited. In this work, BSFs were comprehensively estimated for all ISO-recommended phantoms-slab, cylindrical, pillar, and rod-over a photon energy range of 10 keV-2 MeV and multiple field sizes using the FLUKA Monte Carlo code with an air-kerma-based formalism. The results show a strong coupled dependence of BSF on photon energy and beam size, with a characteristic peak in the intermediate energy range (∼40-80 keV) and geometry-driven variations and field-size sensitivity-maximized in the slab phantom and minimized in the rod due to scattering volume constraints, while cylindrical and pillar phantoms exhibit intermediate behaviour. To extend these results to realistic irradiation conditions, a Python-based standalone tool was developed using PCHIP interpolation and fluence-weighted averaging to compute spectrum-averaged BSFs for ISO 4037 beams, diagnostic and therapeutic spectra, and user-defined spectra, demonstrating deviation within 0%-2.3% with published data. The study provides a BSF dataset across all ISO phantoms along with a validated computational framework, enabling improved accuracy in dosimeter calibration and determination of operational quantities such asH<subscript>p</subscript>(3) andH<subscript>p</subscript>(0.07). The Python-based standalone executable of the BSF software, compatible with both Windows and Linux platforms, along with its complete source code, is provided as open-access supplementary data.<br /> (Creative Commons Attribution license.) – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>Backscatter factor; ISO recommended phantoms; ISO slab phantom; backscatter factor beam size; photon back scattering factor – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260722 <i>Date Completed: </i>20260803 <i>Latest Revision: </i>20260803 – Name: DateUpdate Label: Update Code Group: Date Data: 20260803 – Name: DOI Label: DOI Group: ID Data: 10.1088/1361-6498/ae8e83 – Name: AN Label: PMID Group: ID Data: 42486140 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42486140 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1088/1361-6498/ae8e83 Languages: – Code: eng Text: English Subjects: – SubjectFull: Computer Simulation Type: general – SubjectFull: Radiation Dosage Type: general – SubjectFull: Monte Carlo Method Type: general – SubjectFull: Photons Type: general – SubjectFull: Scattering, Radiation Type: general – SubjectFull: Phantoms, Imaging Type: general – SubjectFull: Radiometry Type: general Titles: – TitleFull: Estimation of backscatter factor in ISO-recommended phantoms for photon beams of different beam sizes using Monte Carlo simulations. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Yadav R – PersonEntity: Name: NameFull: Bakshi AK – PersonEntity: Name: NameFull: Sapra BK IsPartOfRelationships: – BibEntity: Dates: – D: 03 M: 08 Text: 2026 Aug 03 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1361-6498 Numbering: – Type: volume Value: 46 – Type: issue Value: 3 Titles: – TitleFull: Journal of radiological protection : official journal of the Society for Radiological Protection Type: main |
| ResultId | 1 |