Academic Journal
Monte Carlo study of air ionization by X-ray photons and backscattering under diagnostic conditions using the developed Irradose code.
| Title: | Monte Carlo study of air ionization by X-ray photons and backscattering under diagnostic conditions using the developed Irradose code. |
|---|---|
| Authors: | El Basraoui O; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco., Qassimi O; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco., Yahyaoui C; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco., El Amri L; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco., Tahiri N; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco., El Bounagui O; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco. elbounagui@gmail.com. |
| Source: | Radiological physics and technology [Radiol Phys Technol] 2026 Sep; Vol. 19 (3), pp. 1141-1152. Date of Electronic Publication: 2026 Jul 13. |
| Publication Type: | Journal Article |
| Language: | English |
| Journal Info: | Publisher: Springer Japan Country of Publication: Japan NLM ID: 101467995 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1865-0341 (Electronic) Linking ISSN: 18650333 NLM ISO Abbreviation: Radiol Phys Technol Subsets: MEDLINE |
| Imprint Name(s): | Original Publication: Tokyo : Springer Japan |
| MeSH Terms: | Monte Carlo Method* , Photons* , Scattering, Radiation* , Air* , Air Ionization*, Phantoms, Imaging ; X-Rays |
| Abstract: | Irradiation of air by X-rays, particularly during diagnostic and medical imaging procedures, induces a temporary ionization of its constituents and may lead to the formation of reactive species such as O₂+, O₂- and O₂2⁻. This study analyzes photon transport as well as scattering and backscattering phenomena in air and tissue-equivalent media, in order to evaluate dose, energy, and angular distributions. A Monte Carlo code named Irradose has been developed to simulate these processes in cylindrical geometries containing air, an HCNO phantom representing the patient, and an aqueous medium. The model was validated by comparison with the PHITS and Geant4 codes, showing good agreement with deviations below 5%. The results highlight a progressive attenuation of the beam dose in air between the source and the phantom, estimated at 1.2%. They also show a higher dose deposition in the HCNO phantom. Backscatter from this medium contributes significantly to the secondary photon field in air, with a maximum of 14.62% at 0.15 MeV and a dominant angular distribution around 2.4 rad. The ionic species O₂+, O₂- and O₂2- are discussed, as well as the limitations of this work and the associated perspectives. (© 2026. The Author(s), under exclusive licence to Japanese Society of Radiological Technology and Japan Society of Medical Physics.) |
| Competing Interests: | Declarations. Conflicts of interest: The authors declare that they have no conflict of interest. Ethics approval: This study is based on numerical simulations and computational modeling of X-ray–induced air ionization under clinical radiological conditions. No human subjects, biological samples, or direct clinical interventions were involved. Therefore, ethical approval was not required. Informed consent: This study did not involve human participants or patient-specific clinical data. Therefore, informed consent was not required. |
| References: | Research (Wash D C). 2021 Dec 26;2021:9892152. (PMID: 35028585) Commun Chem. 2021 Apr 8;4(1):49. (PMID: 36697542) Front Public Health. 2020 Dec 15;8:601711. (PMID: 33384980) Cureus. 2024 Dec 3;16(12):e75054. (PMID: 39749071) Indian J Radiol Imaging. 2025 Aug 12;36(3):334-344. (PMID: 42344198) Proc Jpn Acad Ser B Phys Biol Sci. 2017;93(6):399-421. (PMID: 28603211) |
| Contributed Indexing: | Keywords: Air ionization; Backscatter flux; HCNO phantom; Monte Carlo simulation; Radiation transport |
| Entry Date(s): | Date Created: 20260713 Date Completed: 20260905 Latest Revision: 20261008 |
| Update Code: | 20261008 |
| DOI: | 10.1007/s12194-026-01094-2 |
| PMID: | 42440061 |
| Database: | MEDLINE |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42440061 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Monte Carlo study of air ionization by X-ray photons and backscattering under diagnostic conditions using the developed Irradose code. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22El+Basraoui+O%22">El Basraoui O</searchLink>; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco.<br /><searchLink fieldCode="AU" term="%22Qassimi+O%22">Qassimi O</searchLink>; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco.<br /><searchLink fieldCode="AU" term="%22Yahyaoui+C%22">Yahyaoui C</searchLink>; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco.<br /><searchLink fieldCode="AU" term="%22El+Amri+L%22">El Amri L</searchLink>; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco.<br /><searchLink fieldCode="AU" term="%22Tahiri+N%22">Tahiri N</searchLink>; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco.<br /><searchLink fieldCode="AU" term="%22El+Bounagui+O%22">El Bounagui O</searchLink>; Laboratory of Condensed Matter and Interdisciplinary Sciences, Mohammed V University in Rabat, Rabat, Morocco. elbounagui@gmail.com. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22101467995%22">Radiological physics and technology</searchLink> [Radiol Phys Technol] 2026 Sep; Vol. 19 (3), pp. 1141-1152. <i>Date of Electronic Publication: </i>2026 Jul 13. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Springer+Japan%22">Springer Japan </searchLink><i>Country of Publication: </i>Japan <i>NLM ID: </i>101467995 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1865-0341 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2218650333%22">18650333 </searchLink><i>NLM ISO Abbreviation: </i>Radiol Phys Technol <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Original Publication</i>: Tokyo : Springer Japan – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Monte+Carlo+Method%22">Monte Carlo Method*</searchLink> <br /><searchLink fieldCode="MM" term="%22Photons%22">Photons*</searchLink> <br /><searchLink fieldCode="MM" term="%22Scattering%2C+Radiation%22">Scattering, Radiation*</searchLink> <br /><searchLink fieldCode="MM" term="%22Air%22">Air*</searchLink> <br /><searchLink fieldCode="MM" term="%22Air+Ionization%22">Air Ionization*</searchLink><br /><searchLink fieldCode="MH" term="%22Phantoms%2C+Imaging%22">Phantoms, Imaging</searchLink> ; <searchLink fieldCode="MH" term="%22X-Rays%22">X-Rays</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Irradiation of air by X-rays, particularly during diagnostic and medical imaging procedures, induces a temporary ionization of its constituents and may lead to the formation of reactive species such as O₂<superscript>+</superscript>, O₂<superscript>-</superscript> and O₂<superscript>2</superscript>⁻. This study analyzes photon transport as well as scattering and backscattering phenomena in air and tissue-equivalent media, in order to evaluate dose, energy, and angular distributions. A Monte Carlo code named Irradose has been developed to simulate these processes in cylindrical geometries containing air, an HCNO phantom representing the patient, and an aqueous medium. The model was validated by comparison with the PHITS and Geant4 codes, showing good agreement with deviations below 5%. The results highlight a progressive attenuation of the beam dose in air between the source and the phantom, estimated at 1.2%. They also show a higher dose deposition in the HCNO phantom. Backscatter from this medium contributes significantly to the secondary photon field in air, with a maximum of 14.62% at 0.15 MeV and a dominant angular distribution around 2.4 rad. The ionic species O₂<superscript>+</superscript>, O₂<superscript>-</superscript> and O₂<superscript>2-</superscript> are discussed, as well as the limitations of this work and the associated perspectives.<br /> (© 2026. The Author(s), under exclusive licence to Japanese Society of Radiological Technology and Japan Society of Medical Physics.) – Name: Abstract Label: Competing Interests Group: Ab Data: Declarations. Conflicts of interest: The authors declare that they have no conflict of interest. Ethics approval: This study is based on numerical simulations and computational modeling of X-ray–induced air ionization under clinical radiological conditions. No human subjects, biological samples, or direct clinical interventions were involved. Therefore, ethical approval was not required. Informed consent: This study did not involve human participants or patient-specific clinical data. Therefore, informed consent was not required. – Name: Ref Label: References Group: RefInfo Data: Research (Wash D C). 2021 Dec 26;2021:9892152. (PMID: <searchLink fieldCode="PM" term="%2235028585%22">35028585)</searchLink><br />Commun Chem. 2021 Apr 8;4(1):49. (PMID: <searchLink fieldCode="PM" term="%2236697542%22">36697542)</searchLink><br />Front Public Health. 2020 Dec 15;8:601711. (PMID: <searchLink fieldCode="PM" term="%2233384980%22">33384980)</searchLink><br />Cureus. 2024 Dec 3;16(12):e75054. (PMID: <searchLink fieldCode="PM" term="%2239749071%22">39749071)</searchLink><br />Indian J Radiol Imaging. 2025 Aug 12;36(3):334-344. (PMID: <searchLink fieldCode="PM" term="%2242344198%22">42344198)</searchLink><br />Proc Jpn Acad Ser B Phys Biol Sci. 2017;93(6):399-421. (PMID: <searchLink fieldCode="PM" term="%2228603211%22">28603211)</searchLink> – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>Air ionization; Backscatter flux; HCNO phantom; Monte Carlo simulation; Radiation transport – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260713 <i>Date Completed: </i>20260905 <i>Latest Revision: </i>20261008 – Name: DateUpdate Label: Update Code Group: Date Data: 20261008 – Name: DOI Label: DOI Group: ID Data: 10.1007/s12194-026-01094-2 – Name: AN Label: PMID Group: ID Data: 42440061 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42440061 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s12194-026-01094-2 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 1141 Subjects: – SubjectFull: Phantoms, Imaging Type: general – SubjectFull: X-Rays Type: general – SubjectFull: Monte Carlo Method Type: general – SubjectFull: Photons Type: general – SubjectFull: Scattering, Radiation Type: general – SubjectFull: Air Type: general – SubjectFull: Air Ionization Type: general Titles: – TitleFull: Monte Carlo study of air ionization by X-ray photons and backscattering under diagnostic conditions using the developed Irradose code. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: El Basraoui O – PersonEntity: Name: NameFull: Qassimi O – PersonEntity: Name: NameFull: Yahyaoui C – PersonEntity: Name: NameFull: El Amri L – PersonEntity: Name: NameFull: Tahiri N – PersonEntity: Name: NameFull: El Bounagui O IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 09 Text: 2026 Sep Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1865-0341 Numbering: – Type: volume Value: 19 – Type: issue Value: 3 Titles: – TitleFull: Radiological physics and technology Type: main |
| ResultId | 1 |