Hybrid dissociation modes in a portable ion trap mass spectrometer for enhanced specificity in complex mixture analysis.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Hybrid dissociation modes in a portable ion trap mass spectrometer for enhanced specificity in complex mixture analysis.
Συγγραφείς: Zhan J; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China., Chen; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China. Electronic address: chenla@nbu.edu.cn., Li G; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China., Wen L; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China; Hua Yue Enterprise Holdings Ltd., Guangzhou, 511400, China. Electronic address: wenluhong@nbu.edu.cn.
Πηγή: Analytica chimica acta [Anal Chim Acta] 2026 Sep 22; Vol. 1416, pp. 345758. Date of Electronic Publication: 2026 May 28.
Τύπος έκδοσης: Journal Article; Research Support, Non-U.S. Gov't
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Elsevier Country of Publication: Netherlands NLM ID: 0370534 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1873-4324 (Electronic) Linking ISSN: 00032670 NLM ISO Abbreviation: Anal Chim Acta Subsets: MEDLINE
Imprint Name(s): Publication: Amsterdam : Elsevier
Original Publication: Amsterdam.
Ιατρικοί όροι (MeSH): Tandem Mass Spectrometry*/instrumentation , Tandem Mass Spectrometry*/methods , Complex Mixtures*/analysis, Hair/chemistry
Περίληψη: Direct ionization ion trap mass spectrometry (ITMS) consistently faces challenges from matrix interference, necessitating highly specific analytical strategies to ensure reliable compound identification. However, the performance of tandem mass spectrometry (MS/MS) in conventional ITMS systems, which primarily rely on collision-induced dissociation (CID) for ion activation-is often constrained by the low-mass cutoff (LMCO) effect and suboptimal fragmentation efficiency. To address these limitations, we developed a portable ITMS platform that integrates both beam-type collision-induced dissociation (bCID) and CID technologies. In this platform, a flared ion guide serves dual roles as an ion transfer device and a collision cell for bCID. Compared with a parallel square-rod ion guide, the flared design-without compromising instrument portability shortens the dissociation time from 40 to 20 ms and increases the total dissociation efficiency by approximately 10%. Experimental results demonstrated that the bCID activation method effectively alleviates the LMCO restriction, while simultaneously improving fragmentation efficiency and analytical throughput, particularly for low-mass fragments. Furthermore, bCID provides greater flexibility in modulating fragment ion abundance through dissociation voltage adjustment and exhibits a distinct advantage in dissociating molecules containing strong chemical bonds. In the analysis of complex matrices such as hair and serum, bCID enhanced the signal-to-noise (S/N) ratios for compounds including tramadol, metonitazene and brodifacoum compared to CID. This enhancement was achieved by strengthening low-mass fragment ion intensities while reducing background noise through the breakdown of matrix-derived interference ions into non-specific fragments. Additionally, the complementary use of CID and bCID offered superior specificity for detecting designer drugs (e.g., etomidate and propoxate) in urine and food additives (e.g., saccharin sodium and benzoic acid) in ham, by generating a sufficient set of diagnostic ions with high abundance and S/N ratios. These findings underscore the importance of incorporating the hybrid dissociation modes into portable ITMS systems for on-site analysis of complex samples.
(Copyright © 2026 Elsevier B.V. All rights reserved.)
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Contributed Indexing: Keywords: Direct ionization; Hybrid dissociation modes; Low-mass cutoff effect; Portable ion trap mass spectrometer; Tandem mass spectrometry
Substance Nomenclature: 0 (Complex Mixtures)
Entry Date(s): Date Created: 20260704 Date Completed: 20260704 Latest Revision: 20260707
Update Code: 20260707
DOI: 10.1016/j.aca.2026.345758
PMID: 42401465
Βάση Δεδομένων: MEDLINE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://www.doi.org/10.1016/j.aca.2026.345758?
    Name: ScienceDirect (all content) (s7799221)
    Category: fullText
    Text: View record from ScienceDirect
    MouseOverText: View record from ScienceDirect
  – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=18734324&ISBN=&volume=1416&issue=&date=20260922&spage=345758&pages=345758&title=Analytica chimica acta&atitle=Hybrid%20dissociation%20modes%20in%20a%20portable%20ion%20trap%20mass%20spectrometer%20for%20enhanced%20specificity%20in%20complex%20mixture%20analysis.&aulast=Zhan%20J&id=DOI:10.1016/j.aca.2026.345758
    Name: Full Text Finder (for New FTF UI) (ns324271)
    Category: fullText
    Text: Full Text Finder
    MouseOverText: Full Text Finder
Header DbId: cmedm
DbLabel: MEDLINE
An: 42401465
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Hybrid dissociation modes in a portable ion trap mass spectrometer for enhanced specificity in complex mixture analysis.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Zhan+J%22">Zhan J</searchLink>; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China.<br /><searchLink fieldCode="AU" term="%22Chen%22">Chen</searchLink>; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China. Electronic address: chenla@nbu.edu.cn.<br /><searchLink fieldCode="AU" term="%22Li+G%22">Li G</searchLink>; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China.<br /><searchLink fieldCode="AU" term="%22Wen+L%22">Wen L</searchLink>; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China; Hua Yue Enterprise Holdings Ltd., Guangzhou, 511400, China. Electronic address: wenluhong@nbu.edu.cn.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%220370534%22">Analytica chimica acta</searchLink> [Anal Chim Acta] 2026 Sep 22; Vol. 1416, pp. 345758. <i>Date of Electronic Publication: </i>2026 May 28.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article; Research Support, Non-U.S. Gov't
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Elsevier%22">Elsevier </searchLink><i>Country of Publication: </i>Netherlands <i>NLM ID: </i>0370534 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1873-4324 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200032670%22">00032670 </searchLink><i>NLM ISO Abbreviation: </i>Anal Chim Acta <i>Subsets: </i>MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: <i>Publication</i>: Amsterdam : Elsevier<br /><i>Original Publication</i>: Amsterdam.
– Name: SubjectMESH
  Label: MeSH Terms
  Group: Su
  Data: <searchLink fieldCode="MM" term="%22Tandem+Mass+Spectrometry%22">Tandem Mass Spectrometry*</searchLink>/<searchLink fieldCode="MM" term="%22Tandem+Mass+Spectrometry+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Tandem+Mass+Spectrometry%22">Tandem Mass Spectrometry*</searchLink>/<searchLink fieldCode="MM" term="%22Tandem+Mass+Spectrometry+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Complex+Mixtures%22">Complex Mixtures*</searchLink>/<searchLink fieldCode="MM" term="%22Complex+Mixtures+analysis%22">analysis</searchLink><br /><searchLink fieldCode="MH" term="%22Hair%22">Hair</searchLink>/<searchLink fieldCode="MH" term="%22Hair+chemistry%22">chemistry</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Direct ionization ion trap mass spectrometry (ITMS) consistently faces challenges from matrix interference, necessitating highly specific analytical strategies to ensure reliable compound identification. However, the performance of tandem mass spectrometry (MS/MS) in conventional ITMS systems, which primarily rely on collision-induced dissociation (CID) for ion activation-is often constrained by the low-mass cutoff (LMCO) effect and suboptimal fragmentation efficiency. To address these limitations, we developed a portable ITMS platform that integrates both beam-type collision-induced dissociation (bCID) and CID technologies. In this platform, a flared ion guide serves dual roles as an ion transfer device and a collision cell for bCID. Compared with a parallel square-rod ion guide, the flared design-without compromising instrument portability shortens the dissociation time from 40 to 20 ms and increases the total dissociation efficiency by approximately 10%. Experimental results demonstrated that the bCID activation method effectively alleviates the LMCO restriction, while simultaneously improving fragmentation efficiency and analytical throughput, particularly for low-mass fragments. Furthermore, bCID provides greater flexibility in modulating fragment ion abundance through dissociation voltage adjustment and exhibits a distinct advantage in dissociating molecules containing strong chemical bonds. In the analysis of complex matrices such as hair and serum, bCID enhanced the signal-to-noise (S/N) ratios for compounds including tramadol, metonitazene and brodifacoum compared to CID. This enhancement was achieved by strengthening low-mass fragment ion intensities while reducing background noise through the breakdown of matrix-derived interference ions into non-specific fragments. Additionally, the complementary use of CID and bCID offered superior specificity for detecting designer drugs (e.g., etomidate and propoxate) in urine and food additives (e.g., saccharin sodium and benzoic acid) in ham, by generating a sufficient set of diagnostic ions with high abundance and S/N ratios. These findings underscore the importance of incorporating the hybrid dissociation modes into portable ITMS systems for on-site analysis of complex samples.<br /> (Copyright © 2026 Elsevier B.V. All rights reserved.)
– Name: Abstract
  Label: Competing Interests
  Group: Ab
  Data: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
– Name: SubjectMinor
  Label: Contributed Indexing
  Group:
  Data: <i>Keywords: </i>Direct ionization; Hybrid dissociation modes; Low-mass cutoff effect; Portable ion trap mass spectrometer; Tandem mass spectrometry
– Name: NumberCAS
  Label: Substance Nomenclature
  Group: ID
  Data: 0 (Complex Mixtures)
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: <i>Date Created: </i>20260704 <i>Date Completed: </i>20260704 <i>Latest Revision: </i>20260707
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260707
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1016/j.aca.2026.345758
– Name: AN
  Label: PMID
  Group: ID
  Data: 42401465
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42401465
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.aca.2026.345758
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        StartPage: 345758
    Subjects:
      – SubjectFull: Hair chemistry
        Type: general
      – SubjectFull: Tandem Mass Spectrometry instrumentation
        Type: general
      – SubjectFull: Tandem Mass Spectrometry methods
        Type: general
      – SubjectFull: Complex Mixtures analysis
        Type: general
    Titles:
      – TitleFull: Hybrid dissociation modes in a portable ion trap mass spectrometer for enhanced specificity in complex mixture analysis.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Zhan J
      – PersonEntity:
          Name:
            NameFull: Chen
      – PersonEntity:
          Name:
            NameFull: Li G
      – PersonEntity:
          Name:
            NameFull: Wen L
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 22
              M: 09
              Text: 2026 Sep 22
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 1873-4324
          Numbering:
            – Type: volume
              Value: 1416
          Titles:
            – TitleFull: Analytica chimica acta