Academic Journal
Hybrid dissociation modes in a portable ion trap mass spectrometer for enhanced specificity in complex mixture analysis.
| Τίτλος: | Hybrid dissociation modes in a portable ion trap mass spectrometer for enhanced specificity in complex mixture analysis. |
|---|---|
| Συγγραφείς: | Zhan J; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China., Chen; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China. Electronic address: chenla@nbu.edu.cn., Li G; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China., Wen L; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China; Hua Yue Enterprise Holdings Ltd., Guangzhou, 511400, China. Electronic address: wenluhong@nbu.edu.cn. |
| Πηγή: | Analytica chimica acta [Anal Chim Acta] 2026 Sep 22; Vol. 1416, pp. 345758. Date of Electronic Publication: 2026 May 28. |
| Τύπος έκδοσης: | Journal Article; Research Support, Non-U.S. Gov't |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: Elsevier Country of Publication: Netherlands NLM ID: 0370534 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1873-4324 (Electronic) Linking ISSN: 00032670 NLM ISO Abbreviation: Anal Chim Acta Subsets: MEDLINE |
| Imprint Name(s): | Publication: Amsterdam : Elsevier Original Publication: Amsterdam. |
| Ιατρικοί όροι (MeSH): | Tandem Mass Spectrometry*/instrumentation , Tandem Mass Spectrometry*/methods , Complex Mixtures*/analysis, Hair/chemistry |
| Περίληψη: | Direct ionization ion trap mass spectrometry (ITMS) consistently faces challenges from matrix interference, necessitating highly specific analytical strategies to ensure reliable compound identification. However, the performance of tandem mass spectrometry (MS/MS) in conventional ITMS systems, which primarily rely on collision-induced dissociation (CID) for ion activation-is often constrained by the low-mass cutoff (LMCO) effect and suboptimal fragmentation efficiency. To address these limitations, we developed a portable ITMS platform that integrates both beam-type collision-induced dissociation (bCID) and CID technologies. In this platform, a flared ion guide serves dual roles as an ion transfer device and a collision cell for bCID. Compared with a parallel square-rod ion guide, the flared design-without compromising instrument portability shortens the dissociation time from 40 to 20 ms and increases the total dissociation efficiency by approximately 10%. Experimental results demonstrated that the bCID activation method effectively alleviates the LMCO restriction, while simultaneously improving fragmentation efficiency and analytical throughput, particularly for low-mass fragments. Furthermore, bCID provides greater flexibility in modulating fragment ion abundance through dissociation voltage adjustment and exhibits a distinct advantage in dissociating molecules containing strong chemical bonds. In the analysis of complex matrices such as hair and serum, bCID enhanced the signal-to-noise (S/N) ratios for compounds including tramadol, metonitazene and brodifacoum compared to CID. This enhancement was achieved by strengthening low-mass fragment ion intensities while reducing background noise through the breakdown of matrix-derived interference ions into non-specific fragments. Additionally, the complementary use of CID and bCID offered superior specificity for detecting designer drugs (e.g., etomidate and propoxate) in urine and food additives (e.g., saccharin sodium and benzoic acid) in ham, by generating a sufficient set of diagnostic ions with high abundance and S/N ratios. These findings underscore the importance of incorporating the hybrid dissociation modes into portable ITMS systems for on-site analysis of complex samples. (Copyright © 2026 Elsevier B.V. All rights reserved.) |
| Competing Interests: | Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. |
| Contributed Indexing: | Keywords: Direct ionization; Hybrid dissociation modes; Low-mass cutoff effect; Portable ion trap mass spectrometer; Tandem mass spectrometry |
| Substance Nomenclature: | 0 (Complex Mixtures) |
| Entry Date(s): | Date Created: 20260704 Date Completed: 20260704 Latest Revision: 20260707 |
| Update Code: | 20260707 |
| DOI: | 10.1016/j.aca.2026.345758 |
| PMID: | 42401465 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://www.doi.org/10.1016/j.aca.2026.345758? Name: ScienceDirect (all content) (s7799221) Category: fullText Text: View record from ScienceDirect MouseOverText: View record from ScienceDirect – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=18734324&ISBN=&volume=1416&issue=&date=20260922&spage=345758&pages=345758&title=Analytica chimica acta&atitle=Hybrid%20dissociation%20modes%20in%20a%20portable%20ion%20trap%20mass%20spectrometer%20for%20enhanced%20specificity%20in%20complex%20mixture%20analysis.&aulast=Zhan%20J&id=DOI:10.1016/j.aca.2026.345758 Name: Full Text Finder (for New FTF UI) (ns324271) Category: fullText Text: Full Text Finder MouseOverText: Full Text Finder |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42401465 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Hybrid dissociation modes in a portable ion trap mass spectrometer for enhanced specificity in complex mixture analysis. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Zhan+J%22">Zhan J</searchLink>; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China.<br /><searchLink fieldCode="AU" term="%22Chen%22">Chen</searchLink>; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China. Electronic address: chenla@nbu.edu.cn.<br /><searchLink fieldCode="AU" term="%22Li+G%22">Li G</searchLink>; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China.<br /><searchLink fieldCode="AU" term="%22Wen+L%22">Wen L</searchLink>; The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China; China Innovation Instrument Co. Ltd., Ningbo, 315100, China; Hua Yue Enterprise Holdings Ltd., Guangzhou, 511400, China. Electronic address: wenluhong@nbu.edu.cn. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%220370534%22">Analytica chimica acta</searchLink> [Anal Chim Acta] 2026 Sep 22; Vol. 1416, pp. 345758. <i>Date of Electronic Publication: </i>2026 May 28. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article; Research Support, Non-U.S. Gov't – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Elsevier%22">Elsevier </searchLink><i>Country of Publication: </i>Netherlands <i>NLM ID: </i>0370534 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1873-4324 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200032670%22">00032670 </searchLink><i>NLM ISO Abbreviation: </i>Anal Chim Acta <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Publication</i>: Amsterdam : Elsevier<br /><i>Original Publication</i>: Amsterdam. – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Tandem+Mass+Spectrometry%22">Tandem Mass Spectrometry*</searchLink>/<searchLink fieldCode="MM" term="%22Tandem+Mass+Spectrometry+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Tandem+Mass+Spectrometry%22">Tandem Mass Spectrometry*</searchLink>/<searchLink fieldCode="MM" term="%22Tandem+Mass+Spectrometry+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Complex+Mixtures%22">Complex Mixtures*</searchLink>/<searchLink fieldCode="MM" term="%22Complex+Mixtures+analysis%22">analysis</searchLink><br /><searchLink fieldCode="MH" term="%22Hair%22">Hair</searchLink>/<searchLink fieldCode="MH" term="%22Hair+chemistry%22">chemistry</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Direct ionization ion trap mass spectrometry (ITMS) consistently faces challenges from matrix interference, necessitating highly specific analytical strategies to ensure reliable compound identification. However, the performance of tandem mass spectrometry (MS/MS) in conventional ITMS systems, which primarily rely on collision-induced dissociation (CID) for ion activation-is often constrained by the low-mass cutoff (LMCO) effect and suboptimal fragmentation efficiency. To address these limitations, we developed a portable ITMS platform that integrates both beam-type collision-induced dissociation (bCID) and CID technologies. In this platform, a flared ion guide serves dual roles as an ion transfer device and a collision cell for bCID. Compared with a parallel square-rod ion guide, the flared design-without compromising instrument portability shortens the dissociation time from 40 to 20 ms and increases the total dissociation efficiency by approximately 10%. Experimental results demonstrated that the bCID activation method effectively alleviates the LMCO restriction, while simultaneously improving fragmentation efficiency and analytical throughput, particularly for low-mass fragments. Furthermore, bCID provides greater flexibility in modulating fragment ion abundance through dissociation voltage adjustment and exhibits a distinct advantage in dissociating molecules containing strong chemical bonds. In the analysis of complex matrices such as hair and serum, bCID enhanced the signal-to-noise (S/N) ratios for compounds including tramadol, metonitazene and brodifacoum compared to CID. This enhancement was achieved by strengthening low-mass fragment ion intensities while reducing background noise through the breakdown of matrix-derived interference ions into non-specific fragments. Additionally, the complementary use of CID and bCID offered superior specificity for detecting designer drugs (e.g., etomidate and propoxate) in urine and food additives (e.g., saccharin sodium and benzoic acid) in ham, by generating a sufficient set of diagnostic ions with high abundance and S/N ratios. These findings underscore the importance of incorporating the hybrid dissociation modes into portable ITMS systems for on-site analysis of complex samples.<br /> (Copyright © 2026 Elsevier B.V. All rights reserved.) – Name: Abstract Label: Competing Interests Group: Ab Data: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>Direct ionization; Hybrid dissociation modes; Low-mass cutoff effect; Portable ion trap mass spectrometer; Tandem mass spectrometry – Name: NumberCAS Label: Substance Nomenclature Group: ID Data: 0 (Complex Mixtures) – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260704 <i>Date Completed: </i>20260704 <i>Latest Revision: </i>20260707 – Name: DateUpdate Label: Update Code Group: Date Data: 20260707 – Name: DOI Label: DOI Group: ID Data: 10.1016/j.aca.2026.345758 – Name: AN Label: PMID Group: ID Data: 42401465 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42401465 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.aca.2026.345758 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 345758 Subjects: – SubjectFull: Hair chemistry Type: general – SubjectFull: Tandem Mass Spectrometry instrumentation Type: general – SubjectFull: Tandem Mass Spectrometry methods Type: general – SubjectFull: Complex Mixtures analysis Type: general Titles: – TitleFull: Hybrid dissociation modes in a portable ion trap mass spectrometer for enhanced specificity in complex mixture analysis. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Zhan J – PersonEntity: Name: NameFull: Chen – PersonEntity: Name: NameFull: Li G – PersonEntity: Name: NameFull: Wen L IsPartOfRelationships: – BibEntity: Dates: – D: 22 M: 09 Text: 2026 Sep 22 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1873-4324 Numbering: – Type: volume Value: 1416 Titles: – TitleFull: Analytica chimica acta Type: main |
| ResultId | 1 |