Academic Journal
Development of CaSO4: Dy-based ring badge for extremity dose monitoring of radiation workers in India.
| Τίτλος: | Development of CaSO4: Dy-based ring badge for extremity dose monitoring of radiation workers in India. |
|---|---|
| Συγγραφείς: | Srivastava K; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India., Yadav R; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India., Chakrabarty S; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India., Minal P; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India., Singh SK; Radiation Safety & Systems Division, Bhabha Atomic Research Centre, Mumbai 400 085, India., Bakshi AK; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.; Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094, India., Sapra BK; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.; Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094, India. |
| Πηγή: | Radiation protection dosimetry [Radiat Prot Dosimetry] 2026 Oct 06; Vol. 202 (16), pp. 1315-1326. |
| Τύπος έκδοσης: | Journal Article |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: Oxford University Press Country of Publication: England NLM ID: 8109958 Publication Model: Print Cited Medium: Internet ISSN: 1742-3406 (Electronic) Linking ISSN: 01448420 NLM ISO Abbreviation: Radiat Prot Dosimetry Subsets: MEDLINE |
| Imprint Name(s): | Publication: 2004- : Oxford, UK : Oxford University Press Original Publication: Ashford, Kent : Nuclear Technology Pub., c1981- |
| Ιατρικοί όροι (MeSH): | Radiation Monitoring*/instrumentation , Radiation Monitoring*/methods , Thermoluminescent Dosimetry*/instrumentation , Thermoluminescent Dosimetry*/methods , Radiation Protection*/instrumentation , Radiation Protection*/methods , Occupational Exposure*/analysis , Dysprosium*/chemistry , Extremities*/radiation effects, Humans ; India ; Radiation Dosage ; Equipment Design ; Calibration ; Algorithms ; Radiation Dosimeters |
| Περίληψη: | A new compact three-element Extremity Ring Badge (ERB) dosemeter has been developed for extremity dose monitoring of Indian radiation workers. This three-element dosemeter is based on indigenously developed CaSO4:Dy-Teflon discs as a thermoluminescent detector placed between suitable filters in a plastic holder. The dosemeter is designed and calibrated to measure the dose equivalent in terms of operational quantity Hp(0.07) at finger location. It can measure the doses from gamma, beta, and low-energy X-ray radiations and distinguish the beam quality (photon/beta) as well. The design features and results of the experimental studies conducted towards development of ERB dosemeter are presented. The dosemeter demonstrated satisfactory performance in the European Radiation Dosimetry Group (EURADOS) interlaboratory exercise (IC2024ext). The response of all test dosemeters were well within the trumpet curve, as per IEO 14146:2018 criteria, which validates the dose evaluation algorithm used for estimation of Hp(0.07) in the IC2024ext exercise. (© The Author(s) 2026. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.) |
| Substance Nomenclature: | 1D4N45714Q (Dysprosium) |
| Entry Date(s): | Date Created: 20260702 Date Completed: 20261006 Latest Revision: 20261006 |
| Update Code: | 20261006 |
| DOI: | 10.1093/rpd/ncag064 |
| PMID: | 42390974 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Links: – Type: other Url: https://resolver.ebsco.com:443/public/rma-ftfapi/ejs/direct?AccessToken=46178979A8D10F0B896D&Show=Object Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42390974 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Development of CaSO4: Dy-based ring badge for extremity dose monitoring of radiation workers in India. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Srivastava+K%22">Srivastava K</searchLink>; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.<br /><searchLink fieldCode="AU" term="%22Yadav+R%22">Yadav R</searchLink>; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.<br /><searchLink fieldCode="AU" term="%22Chakrabarty+S%22">Chakrabarty S</searchLink>; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.<br /><searchLink fieldCode="AU" term="%22Minal+P%22">Minal P</searchLink>; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.<br /><searchLink fieldCode="AU" term="%22Singh+SK%22">Singh SK</searchLink>; Radiation Safety & Systems Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.<br /><searchLink fieldCode="AU" term="%22Bakshi+AK%22">Bakshi AK</searchLink>; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.; Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094, India.<br /><searchLink fieldCode="AU" term="%22Sapra+BK%22">Sapra BK</searchLink>; Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.; Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094, India. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%228109958%22">Radiation protection dosimetry</searchLink> [Radiat Prot Dosimetry] 2026 Oct 06; Vol. 202 (16), pp. 1315-1326. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Oxford+University+Press%22">Oxford University Press </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>8109958 <i>Publication Model: </i>Print <i>Cited Medium: </i>Internet <i>ISSN: </i>1742-3406 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2201448420%22">01448420 </searchLink><i>NLM ISO Abbreviation: </i>Radiat Prot Dosimetry <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Publication</i>: 2004- : Oxford, UK : Oxford University Press<br /><i>Original Publication</i>: Ashford, Kent : Nuclear Technology Pub., c1981- – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Radiation+Monitoring%22">Radiation Monitoring*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Monitoring+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Monitoring%22">Radiation Monitoring*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Monitoring+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry%22">Thermoluminescent Dosimetry*</searchLink>/<searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry%22">Thermoluminescent Dosimetry*</searchLink>/<searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Protection%22">Radiation Protection*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Protection+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Protection%22">Radiation Protection*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Protection+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Occupational+Exposure%22">Occupational Exposure*</searchLink>/<searchLink fieldCode="MM" term="%22Occupational+Exposure+analysis%22">analysis</searchLink> <br /><searchLink fieldCode="MM" term="%22Dysprosium%22">Dysprosium*</searchLink>/<searchLink fieldCode="MM" term="%22Dysprosium+chemistry%22">chemistry</searchLink> <br /><searchLink fieldCode="MM" term="%22Extremities%22">Extremities*</searchLink>/<searchLink fieldCode="MM" term="%22Extremities+radiation+effects%22">radiation effects</searchLink><br /><searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22India%22">India</searchLink> ; <searchLink fieldCode="MH" term="%22Radiation+Dosage%22">Radiation Dosage</searchLink> ; <searchLink fieldCode="MH" term="%22Equipment+Design%22">Equipment Design</searchLink> ; <searchLink fieldCode="MH" term="%22Calibration%22">Calibration</searchLink> ; <searchLink fieldCode="MH" term="%22Algorithms%22">Algorithms</searchLink> ; <searchLink fieldCode="MH" term="%22Radiation+Dosimeters%22">Radiation Dosimeters</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: A new compact three-element Extremity Ring Badge (ERB) dosemeter has been developed for extremity dose monitoring of Indian radiation workers. This three-element dosemeter is based on indigenously developed CaSO4:Dy-Teflon discs as a thermoluminescent detector placed between suitable filters in a plastic holder. The dosemeter is designed and calibrated to measure the dose equivalent in terms of operational quantity Hp(0.07) at finger location. It can measure the doses from gamma, beta, and low-energy X-ray radiations and distinguish the beam quality (photon/beta) as well. The design features and results of the experimental studies conducted towards development of ERB dosemeter are presented. The dosemeter demonstrated satisfactory performance in the European Radiation Dosimetry Group (EURADOS) interlaboratory exercise (IC2024ext). The response of all test dosemeters were well within the trumpet curve, as per IEO 14146:2018 criteria, which validates the dose evaluation algorithm used for estimation of Hp(0.07) in the IC2024ext exercise.<br /> (© The Author(s) 2026. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.) – Name: NumberCAS Label: Substance Nomenclature Group: ID Data: 1D4N45714Q (Dysprosium) – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260702 <i>Date Completed: </i>20261006 <i>Latest Revision: </i>20261006 – Name: DateUpdate Label: Update Code Group: Date Data: 20261006 – Name: DOI Label: DOI Group: ID Data: 10.1093/rpd/ncag064 – Name: AN Label: PMID Group: ID Data: 42390974 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42390974 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1093/rpd/ncag064 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 1315 Subjects: – SubjectFull: Humans Type: general – SubjectFull: India Type: general – SubjectFull: Radiation Dosage Type: general – SubjectFull: Equipment Design Type: general – SubjectFull: Calibration Type: general – SubjectFull: Algorithms Type: general – SubjectFull: Radiation Dosimeters Type: general – SubjectFull: Radiation Monitoring instrumentation Type: general – SubjectFull: Radiation Monitoring methods Type: general – SubjectFull: Thermoluminescent Dosimetry instrumentation Type: general – SubjectFull: Thermoluminescent Dosimetry methods Type: general – SubjectFull: Radiation Protection instrumentation Type: general – SubjectFull: Radiation Protection methods Type: general – SubjectFull: Occupational Exposure analysis Type: general – SubjectFull: Dysprosium chemistry Type: general – SubjectFull: Extremities radiation effects Type: general Titles: – TitleFull: Development of CaSO4: Dy-based ring badge for extremity dose monitoring of radiation workers in India. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Srivastava K – PersonEntity: Name: NameFull: Yadav R – PersonEntity: Name: NameFull: Chakrabarty S – PersonEntity: Name: NameFull: Minal P – PersonEntity: Name: NameFull: Singh SK – PersonEntity: Name: NameFull: Bakshi AK – PersonEntity: Name: NameFull: Sapra BK IsPartOfRelationships: – BibEntity: Dates: – D: 06 M: 10 Text: 2026 Oct 06 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1742-3406 Numbering: – Type: volume Value: 202 – Type: issue Value: 16 Titles: – TitleFull: Radiation protection dosimetry Type: main |
| ResultId | 1 |