Academic Journal
Optimization of Respiratory Training Methods for Cardiac Magnetic Resonance Imaging.
| Τίτλος: | Optimization of Respiratory Training Methods for Cardiac Magnetic Resonance Imaging. |
|---|---|
| Συγγραφείς: | Ma Z; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.; Hebei Key Laboratory of Precise Imaging of Inflammation Related Tumors, Baoding, China., Zhang X; Department of Ultrasound, Affiliated Hospital of Hebei University, Baoding, China., Li G; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China., Yuan S; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China., Yan G; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China., Wang Z; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China., Zhao Y; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China., Wang J; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China., Yin X; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China. |
| Πηγή: | Journal of magnetic resonance imaging : JMRI [J Magn Reson Imaging] 2026 Oct; Vol. 64 (4), pp. 987-995. Date of Electronic Publication: 2026 Jun 29. |
| Τύπος έκδοσης: | Journal Article |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: Wiley-Liss Country of Publication: United States NLM ID: 9105850 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1522-2586 (Electronic) Linking ISSN: 10531807 NLM ISO Abbreviation: J Magn Reson Imaging Subsets: MEDLINE |
| Imprint Name(s): | Publication: <2005-> : Hoboken , N.J. : Wiley-Liss Original Publication: Chicago, IL : Society for Magnetic Resonance Imaging, c1991- |
| Ιατρικοί όροι (MeSH): | Magnetic Resonance Imaging*/methods , Heart*/diagnostic imaging , Breath Holding* , Breathing Exercises*, Image Enhancement/methods ; Image Processing, Computer-Assisted/methods ; Humans ; Female ; Middle Aged ; Male ; Prospective Studies ; Adult ; Artifacts ; Reproducibility of Results ; Respiration ; Contrast Media |
| Περίληψη: | Background: In cardiac MRI, poor breath-holding may lead to suboptimal image quality. However, the effect of different breath-hold methods on image quality remains unknown. Purpose: To explore the effect of respiratory training with different breath-holding methods and identify the optimal technique for reducing respiratory motion artifacts in cardiac MRI. Study Type: Prospective. Population: A total of 93 patients undergoing cardiac MRI (64 men and 29 women; mean age of 48.9 ± 13.7 years). Field Strength/sequences: 3T, single-shot fast spin-echo sequence, fast imaging employing steady-state acquisition sequence, first-pass perfusion sequence (fast gradient echo), and late gadolinium enhancement sequence (phase-sensitive myocardial delayed enhancement). Assessment: All patients undergoing cardiac MRI were divided into three groups: mouth-breathing, nasal-breathing, and nose-clip. Respiratory-gated monitoring diagrams, examination duration, and subjective and objective image quality assessments were compared. Statistical Tests: One-way ANOVA, Chi-square test, Kruskal-Wallis H test, Kappa test. Statistical significance was set at p < 0.05. Results: Evaluation of the cardiac MRI respiratory-gated monitoring diagrams showed that the probability of good breath-holding in the nose-clip group was 96.7%, significantly higher than in the mouth-breathing (64.5%) and nasal-breathing groups (75.0%). There was no significant difference in examination duration among groups. Myocardial noise in the mouth-breathing group was significantly higher than those in the other two groups (24.2 [18.3, 32.5] vs. 15.8 [12.5, 23.9]/19.2 [13.7, 24.4]); blood pool noise was significantly higher than in the nasal-breathing group (34.6 [22.6, 42.9] vs. 24.9 [18.4, 33.8]). However, CNR did not significantly differ among the three groups (p = 0.07). Subjective image quality scores were higher in the nose-clip group than those in the other two groups (26 [86.7%] versus 16 [51.6%]/18 [56.3%]). Data Conclusion: Optimized respiratory training can enhance breath-holding performance and image quality in patients undergoing cardiac MRI. The use of a nose clip for assisted breath-holding was found to be the most effective method. Evidence Level: 2. Technical Efficacy: Stage 2. (© 2026 International Society for Magnetic Resonance in Medicine.) |
| References: | J Multidiscip Healthc. 2025 Feb 12;18:787-799. (PMID: 39963324) Eur Radiol. 2022 Jul;32(7):4340-4351. (PMID: 35184220) J Cardiovasc Magn Reson. 2021 Nov 8;23(1):126. (PMID: 34743718) J Cardiovasc Magn Reson. 2018 Mar 8;20(1):16. (PMID: 29514708) J Gen Intern Med. 2022 Apr;37(5):1226-1232. (PMID: 35137298) Radiology. 2021 Sep;300(3):539-548. (PMID: 34128724) J Clin Med. 2024 Jan 28;13(3):. (PMID: 38337447) J Magn Reson Imaging. 2011 Jul;34(1):211-9. (PMID: 21618337) Magn Reson Med. 2019 May;81(5):3234-3244. (PMID: 30474151) Eur Radiol. 2016 Aug;26(8):2714-22. (PMID: 26573682) BMC Cardiovasc Disord. 2021 Dec 7;21(1):580. (PMID: 34876015) Curr Med Imaging. 2023;19(9):1090-1095. (PMID: 36453485) Radiology. 2023 Jan;306(1):47-53. (PMID: 35997609) Diagn Interv Imaging. 2023 Nov;104(11):538-546. (PMID: 37328394) Neuroimage. 2021 Apr 15;230:117756. (PMID: 33460797) Korean J Radiol. 2021 Jul;22(7):1044-1053. (PMID: 33856138) Eur Radiol. 2023 Apr;33(4):2289-2300. (PMID: 36357691) Front Cardiovasc Med. 2022 Apr 29;9:884221. (PMID: 35571164) Rofo. 2018 Apr;190(4):341-347. (PMID: 29448290) J Am Heart Assoc. 2022 Jan 4;11(1):e022605. (PMID: 34970923) J Cardiovasc Magn Reson. 2016 Feb 25;18:10. (PMID: 26915830) Ann Neurol. 2018 Mar;83(3):460-471. (PMID: 29420859) Diagnostics (Basel). 2024 Sep 03;14(17):. (PMID: 39272732) Magn Reson Imaging. 2018 Jan;45:43-50. (PMID: 28963048) IEEE Signal Process Mag. 2020 Jan;37(1):111-127. (PMID: 33192036) NMR Biomed. 2021 Feb;34(2):e4433. (PMID: 33258197) Eur Radiol. 2018 Mar;28(3):1132-1139. (PMID: 28986630) Int J Cardiovasc Imaging. 2019 Oct;35(10):1893-1901. (PMID: 31104178) Eur Radiol. 2020 Nov;30(11):5923-5932. (PMID: 32556463) Eur Radiol. 2024 Apr;34(4):2689-2698. (PMID: 37804340) Magn Reson Med. 2021 Mar;85(3):1195-1208. (PMID: 32924188) Clin Imaging. 2015 Jul-Aug;39(4):619-22. (PMID: 25555833) |
| Grant Information: | 20231477 Medical Science Research Project of Hebei; 2023B03 Medical Science Foundation of Hebei University |
| Contributed Indexing: | Keywords: breath‐holding effect; cardiac magnetic resonance; image quality; respiratory training Local Abstract: [plain-language-summary] Cardiac MRI requires patients to hold their breath to prevent blurring from breathing motion, yet many patients struggle with this. This study compared three breath‐holding techniques in 93 patients: mouth‐breathing, nasal‐breathing, and using a nose clip. The nose clip achieved good breath‐holding in 96.7% of patients, versus 64.5% and 75.0% for the other methods and produced the highest image quality. The nose clip is a low‐cost tool requiring no equipment changes. These findings suggest that nose‐clip‐assisted breath‐holding is a practical, effective way to improve cardiac MRI quality in everyday clinical practice. |
| Substance Nomenclature: | 0 (Contrast Media) |
| Entry Date(s): | Date Created: 20260629 Date Completed: 20260916 Latest Revision: 20260918 |
| Update Code: | 20260918 |
| PubMed Central ID: | PMC13578530 |
| DOI: | 10.1002/jmri.70390 |
| PMID: | 42366921 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Links: – Type: other Url: https://resolver.ebsco.com:443/public/rma-ftfapi/ejs/direct?AccessToken=40DC9EF0E1363C6D08D0&Show=Object Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42366921 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Optimization of Respiratory Training Methods for Cardiac Magnetic Resonance Imaging. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Ma+Z%22">Ma Z</searchLink>; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.; Hebei Key Laboratory of Precise Imaging of Inflammation Related Tumors, Baoding, China.<br /><searchLink fieldCode="AU" term="%22Zhang+X%22">Zhang X</searchLink>; Department of Ultrasound, Affiliated Hospital of Hebei University, Baoding, China.<br /><searchLink fieldCode="AU" term="%22Li+G%22">Li G</searchLink>; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.<br /><searchLink fieldCode="AU" term="%22Yuan+S%22">Yuan S</searchLink>; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.<br /><searchLink fieldCode="AU" term="%22Yan+G%22">Yan G</searchLink>; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.<br /><searchLink fieldCode="AU" term="%22Wang+Z%22">Wang Z</searchLink>; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.<br /><searchLink fieldCode="AU" term="%22Zhao+Y%22">Zhao Y</searchLink>; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.<br /><searchLink fieldCode="AU" term="%22Wang+J%22">Wang J</searchLink>; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.<br /><searchLink fieldCode="AU" term="%22Yin+X%22">Yin X</searchLink>; Department of Radiology, Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%229105850%22">Journal of magnetic resonance imaging : JMRI</searchLink> [J Magn Reson Imaging] 2026 Oct; Vol. 64 (4), pp. 987-995. <i>Date of Electronic Publication: </i>2026 Jun 29. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Wiley-Liss%22">Wiley-Liss </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>9105850 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1522-2586 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2210531807%22">10531807 </searchLink><i>NLM ISO Abbreviation: </i>J Magn Reson Imaging <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Publication</i>: <2005-> : Hoboken , N.J. : Wiley-Liss<br /><i>Original Publication</i>: Chicago, IL : Society for Magnetic Resonance Imaging, c1991- – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Magnetic+Resonance+Imaging%22">Magnetic Resonance Imaging*</searchLink>/<searchLink fieldCode="MM" term="%22Magnetic+Resonance+Imaging+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Heart%22">Heart*</searchLink>/<searchLink fieldCode="MM" term="%22Heart+diagnostic+imaging%22">diagnostic imaging</searchLink> <br /><searchLink fieldCode="MM" term="%22Breath+Holding%22">Breath Holding*</searchLink> <br /><searchLink fieldCode="MM" term="%22Breathing+Exercises%22">Breathing Exercises*</searchLink><br /><searchLink fieldCode="MH" term="%22Image+Enhancement%22">Image Enhancement</searchLink>/<searchLink fieldCode="MH" term="%22Image+Enhancement+methods%22">methods</searchLink> ; <searchLink fieldCode="MH" term="%22Image+Processing%2C+Computer-Assisted%22">Image Processing, Computer-Assisted</searchLink>/<searchLink fieldCode="MH" term="%22Image+Processing%2C+Computer-Assisted+methods%22">methods</searchLink> ; <searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22Female%22">Female</searchLink> ; <searchLink fieldCode="MH" term="%22Middle+Aged%22">Middle Aged</searchLink> ; <searchLink fieldCode="MH" term="%22Male%22">Male</searchLink> ; <searchLink fieldCode="MH" term="%22Prospective+Studies%22">Prospective Studies</searchLink> ; <searchLink fieldCode="MH" term="%22Adult%22">Adult</searchLink> ; <searchLink fieldCode="MH" term="%22Artifacts%22">Artifacts</searchLink> ; <searchLink fieldCode="MH" term="%22Reproducibility+of+Results%22">Reproducibility of Results</searchLink> ; <searchLink fieldCode="MH" term="%22Respiration%22">Respiration</searchLink> ; <searchLink fieldCode="MH" term="%22Contrast+Media%22">Contrast Media</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Background: In cardiac MRI, poor breath-holding may lead to suboptimal image quality. However, the effect of different breath-hold methods on image quality remains unknown.<br />Purpose: To explore the effect of respiratory training with different breath-holding methods and identify the optimal technique for reducing respiratory motion artifacts in cardiac MRI.<br />Study Type: Prospective.<br />Population: A total of 93 patients undergoing cardiac MRI (64 men and 29 women; mean age of 48.9 ± 13.7 years).<br />Field Strength/sequences: 3T, single-shot fast spin-echo sequence, fast imaging employing steady-state acquisition sequence, first-pass perfusion sequence (fast gradient echo), and late gadolinium enhancement sequence (phase-sensitive myocardial delayed enhancement).<br />Assessment: All patients undergoing cardiac MRI were divided into three groups: mouth-breathing, nasal-breathing, and nose-clip. Respiratory-gated monitoring diagrams, examination duration, and subjective and objective image quality assessments were compared.<br />Statistical Tests: One-way ANOVA, Chi-square test, Kruskal-Wallis H test, Kappa test. Statistical significance was set at p &lt; 0.05.<br />Results: Evaluation of the cardiac MRI respiratory-gated monitoring diagrams showed that the probability of good breath-holding in the nose-clip group was 96.7%, significantly higher than in the mouth-breathing (64.5%) and nasal-breathing groups (75.0%). There was no significant difference in examination duration among groups. Myocardial noise in the mouth-breathing group was significantly higher than those in the other two groups (24.2 [18.3, 32.5] vs. 15.8 [12.5, 23.9]/19.2 [13.7, 24.4]); blood pool noise was significantly higher than in the nasal-breathing group (34.6 [22.6, 42.9] vs. 24.9 [18.4, 33.8]). However, CNR did not significantly differ among the three groups (p = 0.07). Subjective image quality scores were higher in the nose-clip group than those in the other two groups (26 [86.7%] versus 16 [51.6%]/18 [56.3%]).<br />Data Conclusion: Optimized respiratory training can enhance breath-holding performance and image quality in patients undergoing cardiac MRI. The use of a nose clip for assisted breath-holding was found to be the most effective method.<br />Evidence Level: 2.<br />Technical Efficacy: Stage 2.<br /> (© 2026 International Society for Magnetic Resonance in Medicine.) – Name: Ref Label: References Group: RefInfo Data: J Multidiscip Healthc. 2025 Feb 12;18:787-799. (PMID: <searchLink fieldCode="PM" term="%2239963324%22">39963324)</searchLink><br />Eur Radiol. 2022 Jul;32(7):4340-4351. (PMID: <searchLink fieldCode="PM" term="%2235184220%22">35184220)</searchLink><br />J Cardiovasc Magn Reson. 2021 Nov 8;23(1):126. (PMID: <searchLink fieldCode="PM" term="%2234743718%22">34743718)</searchLink><br />J Cardiovasc Magn Reson. 2018 Mar 8;20(1):16. (PMID: <searchLink fieldCode="PM" term="%2229514708%22">29514708)</searchLink><br />J Gen Intern Med. 2022 Apr;37(5):1226-1232. (PMID: <searchLink fieldCode="PM" term="%2235137298%22">35137298)</searchLink><br />Radiology. 2021 Sep;300(3):539-548. (PMID: <searchLink fieldCode="PM" term="%2234128724%22">34128724)</searchLink><br />J Clin Med. 2024 Jan 28;13(3):. (PMID: <searchLink fieldCode="PM" term="%2238337447%22">38337447)</searchLink><br />J Magn Reson Imaging. 2011 Jul;34(1):211-9. (PMID: <searchLink fieldCode="PM" term="%2221618337%22">21618337)</searchLink><br />Magn Reson Med. 2019 May;81(5):3234-3244. (PMID: <searchLink fieldCode="PM" term="%2230474151%22">30474151)</searchLink><br />Eur Radiol. 2016 Aug;26(8):2714-22. (PMID: <searchLink fieldCode="PM" term="%2226573682%22">26573682)</searchLink><br />BMC Cardiovasc Disord. 2021 Dec 7;21(1):580. (PMID: <searchLink fieldCode="PM" term="%2234876015%22">34876015)</searchLink><br />Curr Med Imaging. 2023;19(9):1090-1095. (PMID: <searchLink fieldCode="PM" term="%2236453485%22">36453485)</searchLink><br />Radiology. 2023 Jan;306(1):47-53. (PMID: <searchLink fieldCode="PM" term="%2235997609%22">35997609)</searchLink><br />Diagn Interv Imaging. 2023 Nov;104(11):538-546. (PMID: <searchLink fieldCode="PM" term="%2237328394%22">37328394)</searchLink><br />Neuroimage. 2021 Apr 15;230:117756. (PMID: <searchLink fieldCode="PM" term="%2233460797%22">33460797)</searchLink><br />Korean J Radiol. 2021 Jul;22(7):1044-1053. (PMID: <searchLink fieldCode="PM" term="%2233856138%22">33856138)</searchLink><br />Eur Radiol. 2023 Apr;33(4):2289-2300. (PMID: <searchLink fieldCode="PM" term="%2236357691%22">36357691)</searchLink><br />Front Cardiovasc Med. 2022 Apr 29;9:884221. (PMID: <searchLink fieldCode="PM" term="%2235571164%22">35571164)</searchLink><br />Rofo. 2018 Apr;190(4):341-347. (PMID: <searchLink fieldCode="PM" term="%2229448290%22">29448290)</searchLink><br />J Am Heart Assoc. 2022 Jan 4;11(1):e022605. (PMID: <searchLink fieldCode="PM" term="%2234970923%22">34970923)</searchLink><br />J Cardiovasc Magn Reson. 2016 Feb 25;18:10. (PMID: <searchLink fieldCode="PM" term="%2226915830%22">26915830)</searchLink><br />Ann Neurol. 2018 Mar;83(3):460-471. (PMID: <searchLink fieldCode="PM" term="%2229420859%22">29420859)</searchLink><br />Diagnostics (Basel). 2024 Sep 03;14(17):. (PMID: <searchLink fieldCode="PM" term="%2239272732%22">39272732)</searchLink><br />Magn Reson Imaging. 2018 Jan;45:43-50. (PMID: <searchLink fieldCode="PM" term="%2228963048%22">28963048)</searchLink><br />IEEE Signal Process Mag. 2020 Jan;37(1):111-127. (PMID: <searchLink fieldCode="PM" term="%2233192036%22">33192036)</searchLink><br />NMR Biomed. 2021 Feb;34(2):e4433. (PMID: <searchLink fieldCode="PM" term="%2233258197%22">33258197)</searchLink><br />Eur Radiol. 2018 Mar;28(3):1132-1139. (PMID: <searchLink fieldCode="PM" term="%2228986630%22">28986630)</searchLink><br />Int J Cardiovasc Imaging. 2019 Oct;35(10):1893-1901. (PMID: <searchLink fieldCode="PM" term="%2231104178%22">31104178)</searchLink><br />Eur Radiol. 2020 Nov;30(11):5923-5932. (PMID: <searchLink fieldCode="PM" term="%2232556463%22">32556463)</searchLink><br />Eur Radiol. 2024 Apr;34(4):2689-2698. (PMID: <searchLink fieldCode="PM" term="%2237804340%22">37804340)</searchLink><br />Magn Reson Med. 2021 Mar;85(3):1195-1208. (PMID: <searchLink fieldCode="PM" term="%2232924188%22">32924188)</searchLink><br />Clin Imaging. 2015 Jul-Aug;39(4):619-22. (PMID: <searchLink fieldCode="PM" term="%2225555833%22">25555833)</searchLink> – Name: GrantInfo Label: Grant Information Group: Grant Data: 20231477 Medical Science Research Project of Hebei; 2023B03 Medical Science Foundation of Hebei University – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>breath‐holding effect; cardiac magnetic resonance; image quality; respiratory training<br /><i>Local Abstract: </i>[plain-language-summary] Cardiac MRI requires patients to hold their breath to prevent blurring from breathing motion, yet many patients struggle with this. This study compared three breath‐holding techniques in 93 patients: mouth‐breathing, nasal‐breathing, and using a nose clip. The nose clip achieved good breath‐holding in 96.7% of patients, versus 64.5% and 75.0% for the other methods and produced the highest image quality. The nose clip is a low‐cost tool requiring no equipment changes. These findings suggest that nose‐clip‐assisted breath‐holding is a practical, effective way to improve cardiac MRI quality in everyday clinical practice. – Name: NumberCAS Label: Substance Nomenclature Group: ID Data: 0 (Contrast Media) – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260629 <i>Date Completed: </i>20260916 <i>Latest Revision: </i>20260918 – Name: DateUpdate Label: Update Code Group: Date Data: 20260918 – Name: PubmedCentralID Label: PubMed Central ID Group: ID Data: PMC13578530 – Name: DOI Label: DOI Group: ID Data: 10.1002/jmri.70390 – Name: AN Label: PMID Group: ID Data: 42366921 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42366921 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/jmri.70390 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 987 Subjects: – SubjectFull: Image Enhancement methods Type: general – SubjectFull: Image Processing, Computer-Assisted methods Type: general – SubjectFull: Humans Type: general – SubjectFull: Female Type: general – SubjectFull: Middle Aged Type: general – SubjectFull: Male Type: general – SubjectFull: Prospective Studies Type: general – SubjectFull: Adult Type: general – SubjectFull: Artifacts Type: general – SubjectFull: Reproducibility of Results Type: general – SubjectFull: Respiration Type: general – SubjectFull: Contrast Media Type: general – SubjectFull: Magnetic Resonance Imaging methods Type: general – SubjectFull: Heart diagnostic imaging Type: general – SubjectFull: Breath Holding Type: general – SubjectFull: Breathing Exercises Type: general Titles: – TitleFull: Optimization of Respiratory Training Methods for Cardiac Magnetic Resonance Imaging. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Ma Z – PersonEntity: Name: NameFull: Zhang X – PersonEntity: Name: NameFull: Li G – PersonEntity: Name: NameFull: Yuan S – PersonEntity: Name: NameFull: Yan G – PersonEntity: Name: NameFull: Wang Z – PersonEntity: Name: NameFull: Zhao Y – PersonEntity: Name: NameFull: Wang J – PersonEntity: Name: NameFull: Yin X IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: 2026 Oct Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1522-2586 Numbering: – Type: volume Value: 64 – Type: issue Value: 4 Titles: – TitleFull: Journal of magnetic resonance imaging : JMRI Type: main |
| ResultId | 1 |