Academic Journal
Comparison of four attenuation-compensation methods for backscatter coefficient estimation and characterization of focal liver lesions.
| Τίτλος: | Comparison of four attenuation-compensation methods for backscatter coefficient estimation and characterization of focal liver lesions. |
|---|---|
| Συγγραφείς: | Héroux A; Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada., Destrempes F; Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada., Rafati I; Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada., Maxime B; Clinical Laboratory of Image Processing, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada., Karam E; Clinical Laboratory of Image Processing, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada., Fohlen A; Clinical Laboratory of Image Processing, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada., Nguyen BN; Department of Pathology, University of Montreal Hospital, Montréal, Québec, Canada., Castel H; Departments of Hepatology and Liver Transplantation, University of Montreal Hospital, Montréal, Québec, Canada., Tang A; Clinical Laboratory of Image Processing, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada., Cloutier G; Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada. |
| Πηγή: | Physics in medicine and biology [Phys Med Biol] 2026 Jul 02; Vol. 71 (13). Date of Electronic Publication: 2026 Jul 02. |
| Τύπος έκδοσης: | Journal Article; Comparative Study |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: IOP Publishing Country of Publication: England NLM ID: 0401220 Publication Model: Electronic Cited Medium: Internet ISSN: 1361-6560 (Electronic) Linking ISSN: 00319155 NLM ISO Abbreviation: Phys Med Biol Subsets: MEDLINE |
| Imprint Name(s): | Original Publication: Bristol : IOP Publishing |
| Ιατρικοί όροι (MeSH): | Liver Neoplasms*/diagnostic imaging , Liver Neoplasms*/pathology , Image Processing, Computer-Assisted*/methods , Scattering, Radiation*, Humans ; Ultrasonography ; Signal-To-Noise Ratio ; Phantoms, Imaging |
| Περίληψη: | Objective.To compare four attenuation-compensation methods for backscatter coefficient (BSC) estimation, assessment of contrast, and classification of focal liver lesions (FLL).Approach. Ninety-seven patients with 100 FLL were scanned to collect radiofrequency ultrasound images. BSC methods relied on a reference phantom for system and operator-settings independent estimations. Method #1 employeda prioritissue layer segmentation and documented attenuation coefficients (AC) of each layer. Method #2 used a fixed total AC (0.85 dB/cm/MHz). Method #3 used local AC compensation. Method #4 jointly estimated total AC and BSC with a power law frequency model (bfη). BSC@3 MHz,b,η, total AC slope, and total AC were computed within segmented lesions. Lesion contrast was assessed with the contrast-to-noise ratio (CNR) and classification performances were evaluated with the area under the receiver operating characteristic curve (AUC). The composite clinical reference standard was a combination of MRI and histopathology.Main results.The study included 30 primary and 26 secondary cancers, and 44 benign nodules. Parameterbprovided the highest CNRs among BSC parameters (p< 0.0001) and gave higher CNRs than B-mode images (p< 0.0001). Method #3 was unsuitable with out-of-range values. Methods #1, #2, and #4 showed no significant differences forb,η, total AC slope, and total AC, whereas BSC@3 MHz showed overestimations with Method #4 compared with Methods #1 and #2 (p< 0.001 andp< 0.0001, respectively). For differentiating benign and malignant lesions,ηprovided the highest AUC of 0.73 (95% confidence interval (CI): 0.62-0.82). For differentiating primary and secondary cancers, BSC@3 MHz provided the highest AUC of 0.71 (95% CI: 0.55-0.83). Classification AUCs did not differ between Methods #1, #2 and #4.Significance. BSC imaging improved lesion contrast compared to B-mode and could classify FLL. Method #4 emerged as the most practical as it does not require anya prioriAC or segmentation. (Creative Commons Attribution license.) |
| Contributed Indexing: | Keywords: attenuation compensation; backscatter coefficient; focal liver lesion; hepatocellular carcinoma; quantitative ultrasound; ultrasound imaging |
| Entry Date(s): | Date Created: 20260612 Date Completed: 20260702 Latest Revision: 20260702 |
| Update Code: | 20260702 |
| DOI: | 10.1088/1361-6560/ae7cd1 |
| PMID: | 42285137 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42285137 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Comparison of four attenuation-compensation methods for backscatter coefficient estimation and characterization of focal liver lesions. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Héroux+A%22">Héroux A</searchLink>; Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada.<br /><searchLink fieldCode="AU" term="%22Destrempes+F%22">Destrempes F</searchLink>; Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada.<br /><searchLink fieldCode="AU" term="%22Rafati+I%22">Rafati I</searchLink>; Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada.<br /><searchLink fieldCode="AU" term="%22Maxime+B%22">Maxime B</searchLink>; Clinical Laboratory of Image Processing, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada.<br /><searchLink fieldCode="AU" term="%22Karam+E%22">Karam E</searchLink>; Clinical Laboratory of Image Processing, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada.<br /><searchLink fieldCode="AU" term="%22Fohlen+A%22">Fohlen A</searchLink>; Clinical Laboratory of Image Processing, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada.<br /><searchLink fieldCode="AU" term="%22Nguyen+BN%22">Nguyen BN</searchLink>; Department of Pathology, University of Montreal Hospital, Montréal, Québec, Canada.<br /><searchLink fieldCode="AU" term="%22Castel+H%22">Castel H</searchLink>; Departments of Hepatology and Liver Transplantation, University of Montreal Hospital, Montréal, Québec, Canada.<br /><searchLink fieldCode="AU" term="%22Tang+A%22">Tang A</searchLink>; Clinical Laboratory of Image Processing, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada.<br /><searchLink fieldCode="AU" term="%22Cloutier+G%22">Cloutier G</searchLink>; Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada.; Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada.; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%220401220%22">Physics in medicine and biology</searchLink> [Phys Med Biol] 2026 Jul 02; Vol. 71 (13). <i>Date of Electronic Publication: </i>2026 Jul 02. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article; Comparative Study – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22IOP+Publishing%22">IOP Publishing </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>0401220 <i>Publication Model: </i>Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1361-6560 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200319155%22">00319155 </searchLink><i>NLM ISO Abbreviation: </i>Phys Med Biol <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Original Publication</i>: Bristol : IOP Publishing – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Liver+Neoplasms%22">Liver Neoplasms*</searchLink>/<searchLink fieldCode="MM" term="%22Liver+Neoplasms+diagnostic+imaging%22">diagnostic imaging</searchLink> <br /><searchLink fieldCode="MM" term="%22Liver+Neoplasms%22">Liver Neoplasms*</searchLink>/<searchLink fieldCode="MM" term="%22Liver+Neoplasms+pathology%22">pathology</searchLink> <br /><searchLink fieldCode="MM" term="%22Image+Processing%2C+Computer-Assisted%22">Image Processing, Computer-Assisted*</searchLink>/<searchLink fieldCode="MM" term="%22Image+Processing%2C+Computer-Assisted+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Scattering%2C+Radiation%22">Scattering, Radiation*</searchLink><br /><searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22Ultrasonography%22">Ultrasonography</searchLink> ; <searchLink fieldCode="MH" term="%22Signal-To-Noise+Ratio%22">Signal-To-Noise Ratio</searchLink> ; <searchLink fieldCode="MH" term="%22Phantoms%2C+Imaging%22">Phantoms, Imaging</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Objective.To compare four attenuation-compensation methods for backscatter coefficient (BSC) estimation, assessment of contrast, and classification of focal liver lesions (FLL).Approach. Ninety-seven patients with 100 FLL were scanned to collect radiofrequency ultrasound images. BSC methods relied on a reference phantom for system and operator-settings independent estimations. Method #1 employeda prioritissue layer segmentation and documented attenuation coefficients (AC) of each layer. Method #2 used a fixed total AC (0.85 dB/cm/MHz). Method #3 used local AC compensation. Method #4 jointly estimated total AC and BSC with a power law frequency model (bfη). BSC@3 MHz,b,η, total AC slope, and total AC were computed within segmented lesions. Lesion contrast was assessed with the contrast-to-noise ratio (CNR) and classification performances were evaluated with the area under the receiver operating characteristic curve (AUC). The composite clinical reference standard was a combination of MRI and histopathology.Main results.The study included 30 primary and 26 secondary cancers, and 44 benign nodules. Parameterbprovided the highest CNRs among BSC parameters (p&lt; 0.0001) and gave higher CNRs than B-mode images (p&lt; 0.0001). Method #3 was unsuitable with out-of-range values. Methods #1, #2, and #4 showed no significant differences forb,η, total AC slope, and total AC, whereas BSC@3 MHz showed overestimations with Method #4 compared with Methods #1 and #2 (p&lt; 0.001 andp&lt; 0.0001, respectively). For differentiating benign and malignant lesions,ηprovided the highest AUC of 0.73 (95% confidence interval (CI): 0.62-0.82). For differentiating primary and secondary cancers, BSC@3 MHz provided the highest AUC of 0.71 (95% CI: 0.55-0.83). Classification AUCs did not differ between Methods #1, #2 and #4.Significance. BSC imaging improved lesion contrast compared to B-mode and could classify FLL. Method #4 emerged as the most practical as it does not require anya prioriAC or segmentation.<br /> (Creative Commons Attribution license.) – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>attenuation compensation; backscatter coefficient; focal liver lesion; hepatocellular carcinoma; quantitative ultrasound; ultrasound imaging – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260612 <i>Date Completed: </i>20260702 <i>Latest Revision: </i>20260702 – Name: DateUpdate Label: Update Code Group: Date Data: 20260702 – Name: DOI Label: DOI Group: ID Data: 10.1088/1361-6560/ae7cd1 – Name: AN Label: PMID Group: ID Data: 42285137 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42285137 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1088/1361-6560/ae7cd1 Languages: – Code: eng Text: English Subjects: – SubjectFull: Humans Type: general – SubjectFull: Ultrasonography Type: general – SubjectFull: Signal-To-Noise Ratio Type: general – SubjectFull: Phantoms, Imaging Type: general – SubjectFull: Liver Neoplasms diagnostic imaging Type: general – SubjectFull: Liver Neoplasms pathology Type: general – SubjectFull: Image Processing, Computer-Assisted methods Type: general – SubjectFull: Scattering, Radiation Type: general Titles: – TitleFull: Comparison of four attenuation-compensation methods for backscatter coefficient estimation and characterization of focal liver lesions. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Héroux A – PersonEntity: Name: NameFull: Destrempes F – PersonEntity: Name: NameFull: Rafati I – PersonEntity: Name: NameFull: Maxime B – PersonEntity: Name: NameFull: Karam E – PersonEntity: Name: NameFull: Fohlen A – PersonEntity: Name: NameFull: Nguyen BN – PersonEntity: Name: NameFull: Castel H – PersonEntity: Name: NameFull: Tang A – PersonEntity: Name: NameFull: Cloutier G IsPartOfRelationships: – BibEntity: Dates: – D: 02 M: 07 Text: 2026 Jul 02 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1361-6560 Numbering: – Type: volume Value: 71 – Type: issue Value: 13 Titles: – TitleFull: Physics in medicine and biology Type: main |
| ResultId | 1 |