Academic Journal
EURADOS WG10 2019 field test of retrospective dosimetry methods: The NRPI results of mobile phones and salt dosemeters.
| Τίτλος: | EURADOS WG10 2019 field test of retrospective dosimetry methods: The NRPI results of mobile phones and salt dosemeters. |
|---|---|
| Συγγραφείς: | Čemusová Z; National Radiation Protection Institute, Bartoškova 28, 14000 Prague, Czech Republic., Ekendahl D; National Radiation Protection Institute, Bartoškova 28, 14000 Prague, Czech Republic. |
| Πηγή: | Radiation protection dosimetry [Radiat Prot Dosimetry] 2026 Sep 22; Vol. 202 (15), pp. 1245-1252. |
| Τύπος έκδοσης: | Journal Article |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: Oxford University Press Country of Publication: England NLM ID: 8109958 Publication Model: Print Cited Medium: Internet ISSN: 1742-3406 (Electronic) Linking ISSN: 01448420 NLM ISO Abbreviation: Radiat Prot Dosimetry Subsets: MEDLINE |
| Imprint Name(s): | Publication: 2004- : Oxford, UK : Oxford University Press Original Publication: Ashford, Kent : Nuclear Technology Pub., c1981- |
| Ιατρικοί όροι (MeSH): | Radiation Monitoring*/methods , Radiation Monitoring*/instrumentation , Radiation Dosimeters*/standards , Radiation Protection*/methods , Radiation Protection*/instrumentation , Sodium Chloride*/analysis , Radiometry*/methods , Radiometry*/instrumentation , Cell Phone*, Humans ; Radiation Dosage ; Retrospective Studies ; Europe ; Phantoms, Imaging |
| Περίληψη: | Various methods of physical retrospective dosimetry based mainly on thermally and optically stimulated luminescence in daily-use items are employed to assess the dose after unplanned radiation exposure. The investigations are usually performed in laboratory conditions, but the situation will differ in a real scenario. This was the motivation for the field test organized by European Radiation Dosimetry Group and Running the European Network of Biological and Retrospective Physical Dosimetry. The field test was arranged outdoors, where phantoms equipped with mobile phones, payment cards, pieces of dental ceramics and enamel, salty snacks and salt dosemeters, cigarettes and textile bags were irradiated. This manuscript presents doses estimated at National Radiation Protection Institute, as one of participating laboratories, using mobile phones and salt dosemeters in comparison with reference values. When using glass from the display, acceptable agreement was achieved for emergency dosimetry purposes. Resistors and salt measurements led to a more significant overestimation, in the case of resistors up to five times the reference value. (© The Author(s) 2026. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.) |
| Grant Information: | EURADOS WG10; RENEB and Public Health England |
| Substance Nomenclature: | 451W47IQ8X (Sodium Chloride) |
| Entry Date(s): | Date Created: 20260609 Date Completed: 20260922 Latest Revision: 20260922 |
| Update Code: | 20260923 |
| DOI: | 10.1093/rpd/ncag051 |
| PMID: | 42263149 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=17423406&ISBN=&volume=202&issue=15&date=20260922&spage=1245&pages=1245-1252&title=Radiation protection dosimetry&atitle=EURADOS%20WG10%202019%20field%20test%20of%20retrospective%20dosimetry%20methods%3A%20The%20NRPI%20results%20of%20mobile%20phones%20and%20salt%20dosemeters.&aulast=%C4%8Cemusov%C3%A1%20Z&id=DOI:10.1093/rpd/ncag051 Name: Full Text Finder (for New FTF UI) (ns324271) Category: fullText Text: Full Text Finder MouseOverText: Full Text Finder |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42263149 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: EURADOS WG10 2019 field test of retrospective dosimetry methods: The NRPI results of mobile phones and salt dosemeters. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Čemusová+Z%22">Čemusová Z</searchLink>; National Radiation Protection Institute, Bartoškova 28, 14000 Prague, Czech Republic.<br /><searchLink fieldCode="AU" term="%22Ekendahl+D%22">Ekendahl D</searchLink>; National Radiation Protection Institute, Bartoškova 28, 14000 Prague, Czech Republic. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%228109958%22">Radiation protection dosimetry</searchLink> [Radiat Prot Dosimetry] 2026 Sep 22; Vol. 202 (15), pp. 1245-1252. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Oxford+University+Press%22">Oxford University Press </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>8109958 <i>Publication Model: </i>Print <i>Cited Medium: </i>Internet <i>ISSN: </i>1742-3406 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2201448420%22">01448420 </searchLink><i>NLM ISO Abbreviation: </i>Radiat Prot Dosimetry <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Publication</i>: 2004- : Oxford, UK : Oxford University Press<br /><i>Original Publication</i>: Ashford, Kent : Nuclear Technology Pub., c1981- – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Radiation+Monitoring%22">Radiation Monitoring*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Monitoring+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Monitoring%22">Radiation Monitoring*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Monitoring+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Dosimeters%22">Radiation Dosimeters*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Dosimeters+standards%22">standards</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Protection%22">Radiation Protection*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Protection+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Protection%22">Radiation Protection*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Protection+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Sodium+Chloride%22">Sodium Chloride*</searchLink>/<searchLink fieldCode="MM" term="%22Sodium+Chloride+analysis%22">analysis</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiometry%22">Radiometry*</searchLink>/<searchLink fieldCode="MM" term="%22Radiometry+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiometry%22">Radiometry*</searchLink>/<searchLink fieldCode="MM" term="%22Radiometry+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Cell+Phone%22">Cell Phone*</searchLink><br /><searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22Radiation+Dosage%22">Radiation Dosage</searchLink> ; <searchLink fieldCode="MH" term="%22Retrospective+Studies%22">Retrospective Studies</searchLink> ; <searchLink fieldCode="MH" term="%22Europe%22">Europe</searchLink> ; <searchLink fieldCode="MH" term="%22Phantoms%2C+Imaging%22">Phantoms, Imaging</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Various methods of physical retrospective dosimetry based mainly on thermally and optically stimulated luminescence in daily-use items are employed to assess the dose after unplanned radiation exposure. The investigations are usually performed in laboratory conditions, but the situation will differ in a real scenario. This was the motivation for the field test organized by European Radiation Dosimetry Group and Running the European Network of Biological and Retrospective Physical Dosimetry. The field test was arranged outdoors, where phantoms equipped with mobile phones, payment cards, pieces of dental ceramics and enamel, salty snacks and salt dosemeters, cigarettes and textile bags were irradiated. This manuscript presents doses estimated at National Radiation Protection Institute, as one of participating laboratories, using mobile phones and salt dosemeters in comparison with reference values. When using glass from the display, acceptable agreement was achieved for emergency dosimetry purposes. Resistors and salt measurements led to a more significant overestimation, in the case of resistors up to five times the reference value.<br /> (© The Author(s) 2026. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.) – Name: GrantInfo Label: Grant Information Group: Grant Data: EURADOS WG10; RENEB and Public Health England – Name: NumberCAS Label: Substance Nomenclature Group: ID Data: 451W47IQ8X (Sodium Chloride) – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260609 <i>Date Completed: </i>20260922 <i>Latest Revision: </i>20260922 – Name: DateUpdate Label: Update Code Group: Date Data: 20260923 – Name: DOI Label: DOI Group: ID Data: 10.1093/rpd/ncag051 – Name: AN Label: PMID Group: ID Data: 42263149 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42263149 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1093/rpd/ncag051 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 1245 Subjects: – SubjectFull: Humans Type: general – SubjectFull: Radiation Dosage Type: general – SubjectFull: Retrospective Studies Type: general – SubjectFull: Europe Type: general – SubjectFull: Phantoms, Imaging Type: general – SubjectFull: Radiation Monitoring methods Type: general – SubjectFull: Radiation Monitoring instrumentation Type: general – SubjectFull: Radiation Dosimeters standards Type: general – SubjectFull: Radiation Protection methods Type: general – SubjectFull: Radiation Protection instrumentation Type: general – SubjectFull: Sodium Chloride analysis Type: general – SubjectFull: Radiometry methods Type: general – SubjectFull: Radiometry instrumentation Type: general – SubjectFull: Cell Phone Type: general Titles: – TitleFull: EURADOS WG10 2019 field test of retrospective dosimetry methods: The NRPI results of mobile phones and salt dosemeters. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Čemusová Z – PersonEntity: Name: NameFull: Ekendahl D IsPartOfRelationships: – BibEntity: Dates: – D: 22 M: 09 Text: 2026 Sep 22 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1742-3406 Numbering: – Type: volume Value: 202 – Type: issue Value: 15 Titles: – TitleFull: Radiation protection dosimetry Type: main |
| ResultId | 1 |