Academic Journal

Effects of K2HPO4and iodinated contrast agents in bone-equivalent solutions on the quantitative accuracy of bone single-photon emission computed tomography.

Bibliographic Details
Title: Effects of K2HPO4and iodinated contrast agents in bone-equivalent solutions on the quantitative accuracy of bone single-photon emission computed tomography.
Authors: Nojima Y; Graduate School of Health Sciences, Niigata University, Niigata, Japan., Suda S; Saiseikai Niigata Kenoh Kikan Hospital, Sanjo, Japan., Yamazaki Y; Graduate School of Health Sciences, Niigata University, Niigata, Japan.
Source: Biomedical physics & engineering express [Biomed Phys Eng Express] 2026 Jun 01; Vol. 12 (3). Date of Electronic Publication: 2026 Jun 01.
Publication Type: Journal Article
Language: English
Journal Info: Publisher: IOP Publishing Ltd Country of Publication: England NLM ID: 101675002 Publication Model: Electronic Cited Medium: Internet ISSN: 2057-1976 (Electronic) Linking ISSN: 20571976 NLM ISO Abbreviation: Biomed Phys Eng Express Subsets: MEDLINE
Imprint Name(s): Original Publication: Bristol : IOP Publishing Ltd., [2015]-
MeSH Terms: Contrast Media*/chemistry , Phosphates*/chemistry , Potassium Compounds*/chemistry , Tomography, Emission-Computed, Single-Photon*/methods , Bone and Bones*/diagnostic imaging , Iodine*/chemistry, Image Processing, Computer-Assisted/methods ; Phantoms, Imaging ; Algorithms ; Humans
Abstract: Quantitative bone single-photon emission computed tomography (SPECT) using99mTc-labeled phosphates has become increasingly feasible due to advances in SPECT/CT technology and reconstruction algorithms. The xSPECT bone algorithm further improves local anatomical fidelity by segmenting CT images into six tissue classes to generate a zone map for context-specific enhancement of spatial resolution. Therefore, when evaluating xSPECT Bone using phantom studies, bone-equivalent solutions must be prepared to ensure that CT values fall within the bone segmentation range. This study aims to clarify how two commonly used substances (dipotassium hydrogen phosphate (K2HPO4) and iodinated contrast agent) affect CT values, zone maps, attenuation coefficients (μ-map), and quantitative accuracy of xSPECT bone. The inner container of the JS 10 SPECT performance phantom was filled with a99mTc solution prepared by dissolving either K2HPO4or iodinated contrast agent in 100 ml of water. Four types of inserts (with no additive or different K2HPO4or iodine concentrations) were placed in the same sectional area. Both K2HPO4and iodine exhibited strong correlations (p< 0.01) between CT values (HU) and mass densities (g ml-1). No significant differences in zone map orμ-map values were observed between K2HPO4and iodine. At equivalent CT values, percentage contrast was significantly higher with iodine than with K2HPO4. Furthermore, K2HPO4demonstrated stable percentage contrast near unity within 158.5-269.7 HU, indicating superior quantitative consistency. The zone maps andμ-maps were similar with K2HPO4and iodine; however, differences in attenuation during SPECT acquisition due to differences in mass density were not considered. This suggests that attenuation correction becomes overcorrected, thereby decreasing quantitative accuracy. These findings indicate that K2HPO4is more suitable than iodine for creating bone equivalent solutions in quantitative bone SPECT phantom studies.
(© 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.)
Contributed Indexing: Keywords: CT value; bone SPECT; mass density; phantom study; xSPECT bone
Substance Nomenclature: 0 (Contrast Media)
B7862WZ632 (potassium phosphate)
0 (Phosphates)
0 (Potassium Compounds)
9679TC07X4 (Iodine)
Entry Date(s): Date Created: 20260521 Date Completed: 20260717 Latest Revision: 20260924
Update Code: 20260925
DOI: 10.1088/2057-1976/ae7118
PMID: 42167289
Database: MEDLINE
FullText Text:
  Availability: 0
Header DbId: cmedm
DbLabel: MEDLINE
An: 42167289
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Effects of K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;and iodinated contrast agents in bone-equivalent solutions on the quantitative accuracy of bone single-photon emission computed tomography.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AU&quot; term=&quot;%22Nojima+Y%22&quot;&gt;Nojima Y&lt;/searchLink&gt;; Graduate School of Health Sciences, Niigata University, Niigata, Japan.&lt;br /&gt;&lt;searchLink fieldCode=&quot;AU&quot; term=&quot;%22Suda+S%22&quot;&gt;Suda S&lt;/searchLink&gt;; Saiseikai Niigata Kenoh Kikan Hospital, Sanjo, Japan.&lt;br /&gt;&lt;searchLink fieldCode=&quot;AU&quot; term=&quot;%22Yamazaki+Y%22&quot;&gt;Yamazaki Y&lt;/searchLink&gt;; Graduate School of Health Sciences, Niigata University, Niigata, Japan.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22101675002%22&quot;&gt;Biomedical physics &amp; engineering express&lt;/searchLink&gt; [Biomed Phys Eng Express] 2026 Jun 01; Vol. 12 (3). &lt;i&gt;Date of Electronic Publication: &lt;/i&gt;2026 Jun 01.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: &lt;i&gt;Publisher: &lt;/i&gt;&lt;searchLink fieldCode=&quot;PB&quot; term=&quot;%22IOP+Publishing+Ltd%22&quot;&gt;IOP Publishing Ltd &lt;/searchLink&gt;&lt;i&gt;Country of Publication: &lt;/i&gt;England &lt;i&gt;NLM ID: &lt;/i&gt;101675002 &lt;i&gt;Publication Model: &lt;/i&gt;Electronic &lt;i&gt;Cited Medium: &lt;/i&gt;Internet &lt;i&gt;ISSN: &lt;/i&gt;2057-1976 (Electronic) &lt;i&gt;Linking ISSN: &lt;/i&gt;&lt;searchLink fieldCode=&quot;IS&quot; term=&quot;%2220571976%22&quot;&gt;20571976 &lt;/searchLink&gt;&lt;i&gt;NLM ISO Abbreviation: &lt;/i&gt;Biomed Phys Eng Express &lt;i&gt;Subsets: &lt;/i&gt;MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: &lt;i&gt;Original Publication&lt;/i&gt;: Bristol : IOP Publishing Ltd., [2015]-
– Name: SubjectMESH
  Label: MeSH Terms
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Contrast+Media%22&quot;&gt;Contrast Media*&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Contrast+Media+chemistry%22&quot;&gt;chemistry&lt;/searchLink&gt; &lt;br /&gt;&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Phosphates%22&quot;&gt;Phosphates*&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Phosphates+chemistry%22&quot;&gt;chemistry&lt;/searchLink&gt; &lt;br /&gt;&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Potassium+Compounds%22&quot;&gt;Potassium Compounds*&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Potassium+Compounds+chemistry%22&quot;&gt;chemistry&lt;/searchLink&gt; &lt;br /&gt;&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Tomography%2C+Emission-Computed%2C+Single-Photon%22&quot;&gt;Tomography, Emission-Computed, Single-Photon*&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Tomography%2C+Emission-Computed%2C+Single-Photon+methods%22&quot;&gt;methods&lt;/searchLink&gt; &lt;br /&gt;&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Bone+and+Bones%22&quot;&gt;Bone and Bones*&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Bone+and+Bones+diagnostic+imaging%22&quot;&gt;diagnostic imaging&lt;/searchLink&gt; &lt;br /&gt;&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Iodine%22&quot;&gt;Iodine*&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MM&quot; term=&quot;%22Iodine+chemistry%22&quot;&gt;chemistry&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Image+Processing%2C+Computer-Assisted%22&quot;&gt;Image Processing, Computer-Assisted&lt;/searchLink&gt;/&lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Image+Processing%2C+Computer-Assisted+methods%22&quot;&gt;methods&lt;/searchLink&gt; ; &lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Phantoms%2C+Imaging%22&quot;&gt;Phantoms, Imaging&lt;/searchLink&gt; ; &lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Algorithms%22&quot;&gt;Algorithms&lt;/searchLink&gt; ; &lt;searchLink fieldCode=&quot;MH&quot; term=&quot;%22Humans%22&quot;&gt;Humans&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Quantitative bone single-photon emission computed tomography (SPECT) using&lt;superscript&gt;99m&lt;/superscript&gt;Tc-labeled phosphates has become increasingly feasible due to advances in SPECT/CT technology and reconstruction algorithms. The xSPECT bone algorithm further improves local anatomical fidelity by segmenting CT images into six tissue classes to generate a zone map for context-specific enhancement of spatial resolution. Therefore, when evaluating xSPECT Bone using phantom studies, bone-equivalent solutions must be prepared to ensure that CT values fall within the bone segmentation range. This study aims to clarify how two commonly used substances (dipotassium hydrogen phosphate (K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;) and iodinated contrast agent) affect CT values, zone maps, attenuation coefficients (μ-map), and quantitative accuracy of xSPECT bone. The inner container of the JS 10 SPECT performance phantom was filled with a&lt;superscript&gt;99m&lt;/superscript&gt;Tc solution prepared by dissolving either K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;or iodinated contrast agent in 100 ml of water. Four types of inserts (with no additive or different K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;or iodine concentrations) were placed in the same sectional area. Both K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;and iodine exhibited strong correlations (p&amp;lt; 0.01) between CT values (HU) and mass densities (g ml&lt;superscript&gt;-1&lt;/superscript&gt;). No significant differences in zone map orμ-map values were observed between K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;and iodine. At equivalent CT values, percentage contrast was significantly higher with iodine than with K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;. Furthermore, K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;demonstrated stable percentage contrast near unity within 158.5-269.7 HU, indicating superior quantitative consistency. The zone maps andμ-maps were similar with K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;and iodine; however, differences in attenuation during SPECT acquisition due to differences in mass density were not considered. This suggests that attenuation correction becomes overcorrected, thereby decreasing quantitative accuracy. These findings indicate that K&lt;subscript&gt;2&lt;/subscript&gt;HPO&lt;subscript&gt;4&lt;/subscript&gt;is more suitable than iodine for creating bone equivalent solutions in quantitative bone SPECT phantom studies.&lt;br /&gt; (&#169; 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.)
– Name: SubjectMinor
  Label: Contributed Indexing
  Group:
  Data: &lt;i&gt;Keywords: &lt;/i&gt;CT value; bone SPECT; mass density; phantom study; xSPECT bone
– Name: NumberCAS
  Label: Substance Nomenclature
  Group: ID
  Data: 0 (Contrast Media)&lt;br /&gt;B7862WZ632 (potassium phosphate)&lt;br /&gt;0 (Phosphates)&lt;br /&gt;0 (Potassium Compounds)&lt;br /&gt;9679TC07X4 (Iodine)
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: &lt;i&gt;Date Created: &lt;/i&gt;20260521 &lt;i&gt;Date Completed: &lt;/i&gt;20260717 &lt;i&gt;Latest Revision: &lt;/i&gt;20260924
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260925
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1088/2057-1976/ae7118
– Name: AN
  Label: PMID
  Group: ID
  Data: 42167289
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42167289
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1088/2057-1976/ae7118
    Languages:
      – Code: eng
        Text: English
    Subjects:
      – SubjectFull: Image Processing, Computer-Assisted methods
        Type: general
      – SubjectFull: Phantoms, Imaging
        Type: general
      – SubjectFull: Algorithms
        Type: general
      – SubjectFull: Humans
        Type: general
      – SubjectFull: Contrast Media chemistry
        Type: general
      – SubjectFull: Phosphates chemistry
        Type: general
      – SubjectFull: Potassium Compounds chemistry
        Type: general
      – SubjectFull: Tomography, Emission-Computed, Single-Photon methods
        Type: general
      – SubjectFull: Bone and Bones diagnostic imaging
        Type: general
      – SubjectFull: Iodine chemistry
        Type: general
    Titles:
      – TitleFull: Effects of K2HPO4and iodinated contrast agents in bone-equivalent solutions on the quantitative accuracy of bone single-photon emission computed tomography.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Nojima Y
      – PersonEntity:
          Name:
            NameFull: Suda S
      – PersonEntity:
          Name:
            NameFull: Yamazaki Y
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: 2026 Jun 01
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 2057-1976
          Numbering:
            – Type: volume
              Value: 12
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Biomedical physics & engineering express
              Type: main
ResultId 1