Effects of K2HPO4and iodinated contrast agents in bone-equivalent solutions on the quantitative accuracy of bone single-photon emission computed tomography.
| Title: | Effects of K |
|---|---|
| Authors: | Nojima Y; Graduate School of Health Sciences, Niigata University, Niigata, Japan., Suda S; Saiseikai Niigata Kenoh Kikan Hospital, Sanjo, Japan., Yamazaki Y; Graduate School of Health Sciences, Niigata University, Niigata, Japan. |
| Source: | Biomedical physics & engineering express [Biomed Phys Eng Express] 2026 Jun 01; Vol. 12 (3). Date of Electronic Publication: 2026 Jun 01. |
| Publication Type: | Journal Article |
| Language: | English |
| Journal Info: | Publisher: IOP Publishing Ltd Country of Publication: England NLM ID: 101675002 Publication Model: Electronic Cited Medium: Internet ISSN: 2057-1976 (Electronic) Linking ISSN: 20571976 NLM ISO Abbreviation: Biomed Phys Eng Express Subsets: MEDLINE |
| Imprint Name(s): | Original Publication: Bristol : IOP Publishing Ltd., [2015]- |
| MeSH Terms: | Contrast Media*/chemistry , Phosphates*/chemistry , Potassium Compounds*/chemistry , Tomography, Emission-Computed, Single-Photon*/methods , Bone and Bones*/diagnostic imaging , Iodine*/chemistry, Image Processing, Computer-Assisted/methods ; Phantoms, Imaging ; Algorithms ; Humans |
| Abstract: | Quantitative bone single-photon emission computed tomography (SPECT) using99mTc-labeled phosphates has become increasingly feasible due to advances in SPECT/CT technology and reconstruction algorithms. The xSPECT bone algorithm further improves local anatomical fidelity by segmenting CT images into six tissue classes to generate a zone map for context-specific enhancement of spatial resolution. Therefore, when evaluating xSPECT Bone using phantom studies, bone-equivalent solutions must be prepared to ensure that CT values fall within the bone segmentation range. This study aims to clarify how two commonly used substances (dipotassium hydrogen phosphate (K (© 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.) |
| Contributed Indexing: | Keywords: CT value; bone SPECT; mass density; phantom study; xSPECT bone |
| Substance Nomenclature: | 0 (Contrast Media) B7862WZ632 (potassium phosphate) 0 (Phosphates) 0 (Potassium Compounds) 9679TC07X4 (Iodine) |
| Entry Date(s): | Date Created: 20260521 Date Completed: 20260717 Latest Revision: 20260924 |
| Update Code: | 20260925 |
| DOI: | 10.1088/2057-1976/ae7118 |
| PMID: | 42167289 |
| Database: | MEDLINE |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 42167289 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Effects of K<subscript>2</subscript>HPO<subscript>4</subscript>and iodinated contrast agents in bone-equivalent solutions on the quantitative accuracy of bone single-photon emission computed tomography. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Nojima+Y%22">Nojima Y</searchLink>; Graduate School of Health Sciences, Niigata University, Niigata, Japan.<br /><searchLink fieldCode="AU" term="%22Suda+S%22">Suda S</searchLink>; Saiseikai Niigata Kenoh Kikan Hospital, Sanjo, Japan.<br /><searchLink fieldCode="AU" term="%22Yamazaki+Y%22">Yamazaki Y</searchLink>; Graduate School of Health Sciences, Niigata University, Niigata, Japan. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22101675002%22">Biomedical physics & engineering express</searchLink> [Biomed Phys Eng Express] 2026 Jun 01; Vol. 12 (3). <i>Date of Electronic Publication: </i>2026 Jun 01. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22IOP+Publishing+Ltd%22">IOP Publishing Ltd </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>101675002 <i>Publication Model: </i>Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>2057-1976 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2220571976%22">20571976 </searchLink><i>NLM ISO Abbreviation: </i>Biomed Phys Eng Express <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Original Publication</i>: Bristol : IOP Publishing Ltd., [2015]- – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Contrast+Media%22">Contrast Media*</searchLink>/<searchLink fieldCode="MM" term="%22Contrast+Media+chemistry%22">chemistry</searchLink> <br /><searchLink fieldCode="MM" term="%22Phosphates%22">Phosphates*</searchLink>/<searchLink fieldCode="MM" term="%22Phosphates+chemistry%22">chemistry</searchLink> <br /><searchLink fieldCode="MM" term="%22Potassium+Compounds%22">Potassium Compounds*</searchLink>/<searchLink fieldCode="MM" term="%22Potassium+Compounds+chemistry%22">chemistry</searchLink> <br /><searchLink fieldCode="MM" term="%22Tomography%2C+Emission-Computed%2C+Single-Photon%22">Tomography, Emission-Computed, Single-Photon*</searchLink>/<searchLink fieldCode="MM" term="%22Tomography%2C+Emission-Computed%2C+Single-Photon+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Bone+and+Bones%22">Bone and Bones*</searchLink>/<searchLink fieldCode="MM" term="%22Bone+and+Bones+diagnostic+imaging%22">diagnostic imaging</searchLink> <br /><searchLink fieldCode="MM" term="%22Iodine%22">Iodine*</searchLink>/<searchLink fieldCode="MM" term="%22Iodine+chemistry%22">chemistry</searchLink><br /><searchLink fieldCode="MH" term="%22Image+Processing%2C+Computer-Assisted%22">Image Processing, Computer-Assisted</searchLink>/<searchLink fieldCode="MH" term="%22Image+Processing%2C+Computer-Assisted+methods%22">methods</searchLink> ; <searchLink fieldCode="MH" term="%22Phantoms%2C+Imaging%22">Phantoms, Imaging</searchLink> ; <searchLink fieldCode="MH" term="%22Algorithms%22">Algorithms</searchLink> ; <searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Quantitative bone single-photon emission computed tomography (SPECT) using<superscript>99m</superscript>Tc-labeled phosphates has become increasingly feasible due to advances in SPECT/CT technology and reconstruction algorithms. The xSPECT bone algorithm further improves local anatomical fidelity by segmenting CT images into six tissue classes to generate a zone map for context-specific enhancement of spatial resolution. Therefore, when evaluating xSPECT Bone using phantom studies, bone-equivalent solutions must be prepared to ensure that CT values fall within the bone segmentation range. This study aims to clarify how two commonly used substances (dipotassium hydrogen phosphate (K<subscript>2</subscript>HPO<subscript>4</subscript>) and iodinated contrast agent) affect CT values, zone maps, attenuation coefficients (μ-map), and quantitative accuracy of xSPECT bone. The inner container of the JS 10 SPECT performance phantom was filled with a<superscript>99m</superscript>Tc solution prepared by dissolving either K<subscript>2</subscript>HPO<subscript>4</subscript>or iodinated contrast agent in 100 ml of water. Four types of inserts (with no additive or different K<subscript>2</subscript>HPO<subscript>4</subscript>or iodine concentrations) were placed in the same sectional area. Both K<subscript>2</subscript>HPO<subscript>4</subscript>and iodine exhibited strong correlations (p&lt; 0.01) between CT values (HU) and mass densities (g ml<superscript>-1</superscript>). No significant differences in zone map orμ-map values were observed between K<subscript>2</subscript>HPO<subscript>4</subscript>and iodine. At equivalent CT values, percentage contrast was significantly higher with iodine than with K<subscript>2</subscript>HPO<subscript>4</subscript>. Furthermore, K<subscript>2</subscript>HPO<subscript>4</subscript>demonstrated stable percentage contrast near unity within 158.5-269.7 HU, indicating superior quantitative consistency. The zone maps andμ-maps were similar with K<subscript>2</subscript>HPO<subscript>4</subscript>and iodine; however, differences in attenuation during SPECT acquisition due to differences in mass density were not considered. This suggests that attenuation correction becomes overcorrected, thereby decreasing quantitative accuracy. These findings indicate that K<subscript>2</subscript>HPO<subscript>4</subscript>is more suitable than iodine for creating bone equivalent solutions in quantitative bone SPECT phantom studies.<br /> (© 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.) – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>CT value; bone SPECT; mass density; phantom study; xSPECT bone – Name: NumberCAS Label: Substance Nomenclature Group: ID Data: 0 (Contrast Media)<br />B7862WZ632 (potassium phosphate)<br />0 (Phosphates)<br />0 (Potassium Compounds)<br />9679TC07X4 (Iodine) – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260521 <i>Date Completed: </i>20260717 <i>Latest Revision: </i>20260924 – Name: DateUpdate Label: Update Code Group: Date Data: 20260925 – Name: DOI Label: DOI Group: ID Data: 10.1088/2057-1976/ae7118 – Name: AN Label: PMID Group: ID Data: 42167289 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42167289 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1088/2057-1976/ae7118 Languages: – Code: eng Text: English Subjects: – SubjectFull: Image Processing, Computer-Assisted methods Type: general – SubjectFull: Phantoms, Imaging Type: general – SubjectFull: Algorithms Type: general – SubjectFull: Humans Type: general – SubjectFull: Contrast Media chemistry Type: general – SubjectFull: Phosphates chemistry Type: general – SubjectFull: Potassium Compounds chemistry Type: general – SubjectFull: Tomography, Emission-Computed, Single-Photon methods Type: general – SubjectFull: Bone and Bones diagnostic imaging Type: general – SubjectFull: Iodine chemistry Type: general Titles: – TitleFull: Effects of K2HPO4and iodinated contrast agents in bone-equivalent solutions on the quantitative accuracy of bone single-photon emission computed tomography. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Nojima Y – PersonEntity: Name: NameFull: Suda S – PersonEntity: Name: NameFull: Yamazaki Y IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 06 Text: 2026 Jun 01 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 2057-1976 Numbering: – Type: volume Value: 12 – Type: issue Value: 3 Titles: – TitleFull: Biomedical physics & engineering express Type: main |
| ResultId | 1 |