Free light chain EQA: Analytical variability with clinical consequences - Data from 25 Italian EQA exercises (2021-2025).

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Free light chain EQA: Analytical variability with clinical consequences - Data from 25 Italian EQA exercises (2021-2025).
Συγγραφείς: Pasotti F; Regional Coordination Center for Laboratory Medicine of Lombardy Region, Milan, Italy., Da Molin S; Regional Coordination Center for Laboratory Medicine of Lombardy Region, Milan, Italy., Bosoni T; Laboratory of Clinical Analysis, IRCCS Policlinico San Matteo, Pavia, Italy., Azzarà G; Regional Coordination Center for Laboratory Medicine of Lombardy Region, Milan, Italy., Liga G; Regional Coordination Center for Laboratory Medicine of Lombardy Region, Milan, Italy., Moriello G; Regional Coordination Center for Laboratory Medicine of Lombardy Region, Milan, Italy., Zaccaria B; Regional Coordination Center for Laboratory Medicine of Lombardy Region, Milan, Italy., Buoro S; Regional Coordination Center for Laboratory Medicine of Lombardy Region, Milan, Italy.
Πηγή: Clinica chimica acta; international journal of clinical chemistry [Clin Chim Acta] 2026 Aug 15; Vol. 590, pp. 121056. Date of Electronic Publication: 2026 May 05.
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Elsevier Country of Publication: Netherlands NLM ID: 1302422 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1873-3492 (Electronic) Linking ISSN: 00098981 NLM ISO Abbreviation: Clin Chim Acta Subsets: MEDLINE
Imprint Name(s): Original Publication: Amsterdam, Elsevier.
Ιατρικοί όροι (MeSH): Immunoglobulin Light Chains*/blood , Immunoglobulin kappa-Chains*/blood , Immunoglobulin lambda-Chains*/blood, Paraproteinemias/diagnosis ; Paraproteinemias/blood ; Humans ; Italy ; Quality Control
Περίληψη: Serum free light chains (FLC) κ and λ, and the κ/λ ratio, are key biomarkers for the diagnosis, risk stratification and monitoring of monoclonal gammopathies. However, substantial between-method variability still limits harmonised interpretation. We analysed five years of external quality assessment (EQA) data from an Italian FLC scheme. Twenty-five EQA rounds (2021-2025) yielded 2218 results: 746 for κ FLC, 746 for λ FLC and 726 for the κ/λ ratio. Data were processed according to ISO 13528 using robust statistics and method-specific peer groups. Inter-laboratory precision within homogeneous peer groups was generally acceptable, with typical coefficients of variation around 10-20% for κ and λ FLC. By contrast, marked between-method differences were observed. Compared with Siemens N Latex, Binding Site Freelite assays yielded approximately two-fold higher mean κ FLC concentrations (relative mean bias ≈ +94%) and lower mean λ FLC concentrations (relative mean bias ≈ -82%), leading to substantial discrepancies in κ/λ ratio interpretation. Stratified analysis across low, intermediate and high concentration bands showed that the positive κ bias of Freelite persisted throughout the analytical range, whereas the global negative λ bias was largely driven by a subset of high-concentration samples with very high N Latex values. Bland-Altman analysis confirmed wide limits of agreement for both analytes. These findings indicate that current FLC assays are not interchangeable and that κ/λ ratios should not be interpreted using universal reference intervals. Method-specific cut-offs, method-consistent follow-up and method-stratified EQA schemes are required pending international standardization of FLC measurement.
(Copyright © 2026 Elsevier B.V. All rights reserved.)
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Contributed Indexing: Keywords: External quality assessment; Free light chains; Laboratory harmonisation; Method comparison; κ/λ ratio
Substance Nomenclature: 0 (Immunoglobulin Light Chains)
0 (Immunoglobulin kappa-Chains)
0 (Immunoglobulin lambda-Chains)
Entry Date(s): Date Created: 20260507 Date Completed: 20260710 Latest Revision: 20260710
Update Code: 20260711
DOI: 10.1016/j.cca.2026.121056
PMID: 42097195
Βάση Δεδομένων: MEDLINE
Περιγραφή
ISSN:1873-3492
DOI:10.1016/j.cca.2026.121056