Academic Journal

From Hp(10) to Hp: impact of implementing ICRU/ICRP report 95 personal dose quantity on CaSO4:Dy-based TLD dosemeters - a Monte Carlo study.

Bibliographic Details
Title: From Hp(10) to Hp: impact of implementing ICRU/ICRP report 95 personal dose quantity on CaSO4:Dy-based TLD dosemeters - a Monte Carlo study.
Authors: Yadav R; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India., Bhattacharya M; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India., Bakshi AK; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.; Homi Bhabha National Institute, Mumbai, 400085, India., Sapra BK; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.; Homi Bhabha National Institute, Mumbai, 400085, India.
Source: Radiation protection dosimetry [Radiat Prot Dosimetry] 2026 Aug 11; Vol. 202 (13), pp. 1043-1056.
Publication Type: Journal Article
Language: English
Journal Info: Publisher: Oxford University Press Country of Publication: England NLM ID: 8109958 Publication Model: Print Cited Medium: Internet ISSN: 1742-3406 (Electronic) Linking ISSN: 01448420 NLM ISO Abbreviation: Radiat Prot Dosimetry Subsets: MEDLINE
Imprint Name(s): Publication: 2004- : Oxford, UK : Oxford University Press
Original Publication: Ashford, Kent : Nuclear Technology Pub., c1981-
MeSH Terms: Thermoluminescent Dosimetry*/instrumentation , Thermoluminescent Dosimetry*/methods , Thermoluminescent Dosimetry*/standards , Radiation Protection*/standards , Radiation Protection*/methods , Radiation Protection*/instrumentation , Radiation Monitoring*/instrumentation , Radiation Monitoring*/methods , Radiation Monitoring*/standards , Calcium Sulfate*/chemistry , Calcium Sulfate*/analysis , Dysprosium*/chemistry , Dysprosium*/analysis , Occupational Exposure*/analysis, Monte Carlo Method ; Radiation Dosage ; Humans ; Algorithms ; Photons ; Computer Simulation ; Radiation Dosimeters ; Reproducibility of Results
Abstract: The International Commission on Radiation Units and Measurements (ICRU), in collaboration with the International Commission on Radiological Protection (ICRP), has introduced new operational quantities in ICRU Report 95. Among these, the personal dose Hp addresses the significant limitations of the currently used Hp (10), which can overestimate the effective dose by up to a factor of 5.5 at photon energies below 70 keV. These changes necessitate a re-estimation of dosemeter response to evaluate potential modifications in dose algorithms and detector design. In this study, the performance of CaSO4:Dy thermoluminescent dosemeter (TLD) badges was investigated for the new operational quantity Hp and compared with the existing Hp (10). The badge response was simulated over photon energy range 12.3-1250 keV using the Monte Carlo Simulation code FLUKA and benchmarked against experimental validation. To correct for energy-dependent overestimation at lower photon energies, a new dose evaluation algorithm for Hp was developed based on disc dose ratio (R12). The disc dose ratio (R12) refers to the ratio of absorbed doses measured in CaSO₄:Dy TL discs D1 and D2 positioned under different filtration conditions within the badge and serves as an energy-sensitive parameter for correcting the over-response of the dosemeter in terms of Hp. The proposed algorithm demonstrated strong compliance with IEC 62387:2020 performance criteria (acceptance range 0.71-1.67), with 95% of estimated Hp values lying within 0.9-1.3 of the delivered dose. These results confirm that CaSO4:Dy TLD badges, when combined with the improved algorithm, are fully compatible with the new operational quantities recommended in ICRU Report 95, ensuring reliable application in personnel dosimetry.
(© The Author(s) 2026. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.)
Substance Nomenclature: WAT0DDB505 (Calcium Sulfate)
1D4N45714Q (Dysprosium)
Entry Date(s): Date Created: 20260430 Date Completed: 20260811 Latest Revision: 20260811
Update Code: 20260811
DOI: 10.1093/rpd/ncag042
PMID: 42059348
Database: MEDLINE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=17423406&ISBN=&volume=202&issue=13&date=20260811&spage=1043&pages=1043-1056&title=Radiation protection dosimetry&atitle=From%20Hp%2810%29%20to%20Hp%3A%20impact%20of%20implementing%20ICRU%2FICRP%20report%2095%20personal%20dose%20quantity%20on%20CaSO4%3ADy-based%20TLD%20dosemeters%20-%20a%20Monte%20Carlo%20study.&aulast=Yadav%20R&id=DOI:10.1093/rpd/ncag042
    Name: Full Text Finder (for New FTF UI) (ns324271)
    Category: fullText
    Text: Full Text Finder
    MouseOverText: Full Text Finder
Header DbId: cmedm
DbLabel: MEDLINE
An: 42059348
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: From Hp(10) to Hp: impact of implementing ICRU/ICRP report 95 personal dose quantity on CaSO4:Dy-based TLD dosemeters - a Monte Carlo study.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Yadav+R%22">Yadav R</searchLink>; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.<br /><searchLink fieldCode="AU" term="%22Bhattacharya+M%22">Bhattacharya M</searchLink>; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.<br /><searchLink fieldCode="AU" term="%22Bakshi+AK%22">Bakshi AK</searchLink>; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.; Homi Bhabha National Institute, Mumbai, 400085, India.<br /><searchLink fieldCode="AU" term="%22Sapra+BK%22">Sapra BK</searchLink>; Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.; Homi Bhabha National Institute, Mumbai, 400085, India.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%228109958%22">Radiation protection dosimetry</searchLink> [Radiat Prot Dosimetry] 2026 Aug 11; Vol. 202 (13), pp. 1043-1056.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Oxford+University+Press%22">Oxford University Press </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>8109958 <i>Publication Model: </i>Print <i>Cited Medium: </i>Internet <i>ISSN: </i>1742-3406 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2201448420%22">01448420 </searchLink><i>NLM ISO Abbreviation: </i>Radiat Prot Dosimetry <i>Subsets: </i>MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: <i>Publication</i>: 2004- : Oxford, UK : Oxford University Press<br /><i>Original Publication</i>: Ashford, Kent : Nuclear Technology Pub., c1981-
– Name: SubjectMESH
  Label: MeSH Terms
  Group: Su
  Data: <searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry%22">Thermoluminescent Dosimetry*</searchLink>/<searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry%22">Thermoluminescent Dosimetry*</searchLink>/<searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry%22">Thermoluminescent Dosimetry*</searchLink>/<searchLink fieldCode="MM" term="%22Thermoluminescent+Dosimetry+standards%22">standards</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Protection%22">Radiation Protection*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Protection+standards%22">standards</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Protection%22">Radiation Protection*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Protection+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Protection%22">Radiation Protection*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Protection+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Monitoring%22">Radiation Monitoring*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Monitoring+instrumentation%22">instrumentation</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Monitoring%22">Radiation Monitoring*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Monitoring+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Radiation+Monitoring%22">Radiation Monitoring*</searchLink>/<searchLink fieldCode="MM" term="%22Radiation+Monitoring+standards%22">standards</searchLink> <br /><searchLink fieldCode="MM" term="%22Calcium+Sulfate%22">Calcium Sulfate*</searchLink>/<searchLink fieldCode="MM" term="%22Calcium+Sulfate+chemistry%22">chemistry</searchLink> <br /><searchLink fieldCode="MM" term="%22Calcium+Sulfate%22">Calcium Sulfate*</searchLink>/<searchLink fieldCode="MM" term="%22Calcium+Sulfate+analysis%22">analysis</searchLink> <br /><searchLink fieldCode="MM" term="%22Dysprosium%22">Dysprosium*</searchLink>/<searchLink fieldCode="MM" term="%22Dysprosium+chemistry%22">chemistry</searchLink> <br /><searchLink fieldCode="MM" term="%22Dysprosium%22">Dysprosium*</searchLink>/<searchLink fieldCode="MM" term="%22Dysprosium+analysis%22">analysis</searchLink> <br /><searchLink fieldCode="MM" term="%22Occupational+Exposure%22">Occupational Exposure*</searchLink>/<searchLink fieldCode="MM" term="%22Occupational+Exposure+analysis%22">analysis</searchLink><br /><searchLink fieldCode="MH" term="%22Monte+Carlo+Method%22">Monte Carlo Method</searchLink> ; <searchLink fieldCode="MH" term="%22Radiation+Dosage%22">Radiation Dosage</searchLink> ; <searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22Algorithms%22">Algorithms</searchLink> ; <searchLink fieldCode="MH" term="%22Photons%22">Photons</searchLink> ; <searchLink fieldCode="MH" term="%22Computer+Simulation%22">Computer Simulation</searchLink> ; <searchLink fieldCode="MH" term="%22Radiation+Dosimeters%22">Radiation Dosimeters</searchLink> ; <searchLink fieldCode="MH" term="%22Reproducibility+of+Results%22">Reproducibility of Results</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The International Commission on Radiation Units and Measurements (ICRU), in collaboration with the International Commission on Radiological Protection (ICRP), has introduced new operational quantities in ICRU Report 95. Among these, the personal dose Hp addresses the significant limitations of the currently used Hp (10), which can overestimate the effective dose by up to a factor of 5.5 at photon energies below 70 keV. These changes necessitate a re-estimation of dosemeter response to evaluate potential modifications in dose algorithms and detector design. In this study, the performance of CaSO4:Dy thermoluminescent dosemeter (TLD) badges was investigated for the new operational quantity Hp and compared with the existing Hp (10). The badge response was simulated over photon energy range 12.3-1250 keV using the Monte Carlo Simulation code FLUKA and benchmarked against experimental validation. To correct for energy-dependent overestimation at lower photon energies, a new dose evaluation algorithm for Hp was developed based on disc dose ratio (R12). The disc dose ratio (R12) refers to the ratio of absorbed doses measured in CaSO₄:Dy TL discs D1 and D2 positioned under different filtration conditions within the badge and serves as an energy-sensitive parameter for correcting the over-response of the dosemeter in terms of Hp. The proposed algorithm demonstrated strong compliance with IEC 62387:2020 performance criteria (acceptance range 0.71-1.67), with 95% of estimated Hp values lying within 0.9-1.3 of the delivered dose. These results confirm that CaSO4:Dy TLD badges, when combined with the improved algorithm, are fully compatible with the new operational quantities recommended in ICRU Report 95, ensuring reliable application in personnel dosimetry.<br /> (© The Author(s) 2026. Published by Oxford University Press. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.)
– Name: NumberCAS
  Label: Substance Nomenclature
  Group: ID
  Data: WAT0DDB505 (Calcium Sulfate)<br />1D4N45714Q (Dysprosium)
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: <i>Date Created: </i>20260430 <i>Date Completed: </i>20260811 <i>Latest Revision: </i>20260811
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260811
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1093/rpd/ncag042
– Name: AN
  Label: PMID
  Group: ID
  Data: 42059348
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=42059348
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1093/rpd/ncag042
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        StartPage: 1043
    Subjects:
      – SubjectFull: Monte Carlo Method
        Type: general
      – SubjectFull: Radiation Dosage
        Type: general
      – SubjectFull: Humans
        Type: general
      – SubjectFull: Algorithms
        Type: general
      – SubjectFull: Photons
        Type: general
      – SubjectFull: Computer Simulation
        Type: general
      – SubjectFull: Radiation Dosimeters
        Type: general
      – SubjectFull: Reproducibility of Results
        Type: general
      – SubjectFull: Thermoluminescent Dosimetry instrumentation
        Type: general
      – SubjectFull: Thermoluminescent Dosimetry methods
        Type: general
      – SubjectFull: Thermoluminescent Dosimetry standards
        Type: general
      – SubjectFull: Radiation Protection standards
        Type: general
      – SubjectFull: Radiation Protection methods
        Type: general
      – SubjectFull: Radiation Protection instrumentation
        Type: general
      – SubjectFull: Radiation Monitoring instrumentation
        Type: general
      – SubjectFull: Radiation Monitoring methods
        Type: general
      – SubjectFull: Radiation Monitoring standards
        Type: general
      – SubjectFull: Calcium Sulfate chemistry
        Type: general
      – SubjectFull: Calcium Sulfate analysis
        Type: general
      – SubjectFull: Dysprosium chemistry
        Type: general
      – SubjectFull: Dysprosium analysis
        Type: general
      – SubjectFull: Occupational Exposure analysis
        Type: general
    Titles:
      – TitleFull: From Hp(10) to Hp: impact of implementing ICRU/ICRP report 95 personal dose quantity on CaSO4:Dy-based TLD dosemeters - a Monte Carlo study.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Yadav R
      – PersonEntity:
          Name:
            NameFull: Bhattacharya M
      – PersonEntity:
          Name:
            NameFull: Bakshi AK
      – PersonEntity:
          Name:
            NameFull: Sapra BK
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 11
              M: 08
              Text: 2026 Aug 11
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 1742-3406
          Numbering:
            – Type: volume
              Value: 202
            – Type: issue
              Value: 13
          Titles:
            – TitleFull: Radiation protection dosimetry
              Type: main
ResultId 1