Academic Journal

Comfortable Flower Electrodes for Dry EEG in Epilepsy and Clinical Neurophysiology Diagnostics.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Comfortable Flower Electrodes for Dry EEG in Epilepsy and Clinical Neurophysiology Diagnostics.
Συγγραφείς: Dimitrakopoulos D; Department of Neural Dynamics and Magnetoencephalography, Hertie-Institute for Clinical Brain Research, University of Tuebingen, 72076 Tuebingen, Germany.; Institute for Modelling and Simulation of Biomechanical Systems, University of Stuttgart, 70569 Stuttgart, Germany., Marquetand J; Department of Neural Dynamics and Magnetoencephalography, Hertie-Institute for Clinical Brain Research, University of Tuebingen, 72076 Tuebingen, Germany.; Institute for Modelling and Simulation of Biomechanical Systems, University of Stuttgart, 70569 Stuttgart, Germany.; Cerebri GmbH, Neckargasse 7, 72070 Tuebingen, Germany., Kuramatsu J; Department of Neurology, RoMed Clinic Rosenheim, Ellmaierstraße 23, 83022 Rosenheim, Germany.; Department of Neurology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany., Fiedler P; Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Gustav-Kirchhoff-Str. 2, 98693 Ilmenau, Germany., Lang J; Cerebri GmbH, Neckargasse 7, 72070 Tuebingen, Germany.; Department of Neurology, RoMed Clinic Rosenheim, Ellmaierstraße 23, 83022 Rosenheim, Germany.; Department of Neurology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany.
Πηγή: Sensors (Basel, Switzerland) [Sensors (Basel)] 2026 Mar 31; Vol. 26 (7). Date of Electronic Publication: 2026 Mar 31.
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: MDPI Country of Publication: Switzerland NLM ID: 101204366 Publication Model: Electronic Cited Medium: Internet ISSN: 1424-8220 (Electronic) Linking ISSN: 14248220 NLM ISO Abbreviation: Sensors (Basel) Subsets: MEDLINE
Imprint Name(s): Original Publication: Basel, Switzerland : MDPI, c2000-
Ιατρικοί όροι (MeSH): Electroencephalography*/methods , Electroencephalography*/instrumentation , Epilepsy*/diagnosis , Epilepsy*/physiopathology , Neurophysiology*/methods, Humans ; Electrodes ; Signal-To-Noise Ratio ; Female ; Male ; Adult
Περίληψη: Dry electroencephalography (EEG) electrodes enable rapid, gel-free setups, which are crucial for point-of-care diagnostics, but often face challenges with comfort and signal quality-especially in a clinical context. Novel "flower" dry electrodes are a special type of reusable scalp electrodes for dry EEG, featuring a distinct flower-like shape with angled pins in three intertwined layers. While the new electrode design has been validated in an in vivo study on healthy volunteers, we tested its clinical applicability in a proof-of-concept study involving three patients diagnosed with epilepsy and delirium. The recordings were of high diagnostic quality, enabling the reliable identification of pathological patterns, such as generalized spike-wave complexes and intermittent delta activity, with a signal-to-noise ratio comparable to prior reports for sponge-based EEG systems (limited case series). The signal-to-noise ratio (SNR) proved to be sufficiently high for clinical diagnostic purposes, resulting in visually clear and interpretable EEG data that enabled effective assessment of patients' neurophysiological signals. Consequently, our findings demonstrate that the comfortable flower-electrode design is a viable and effective tool for epilepsy diagnostics, extended recording, and clinical neurophysiology. It represents a significant step towards patient-centered and gel-free EEG technology, specifically in point-of-care and emergency applications, without compromising the diagnostic quality of the recordings.
References: IEEE Trans Neural Syst Rehabil Eng. 2018 Apr;26(4):750-757. (PMID: 29641379)
Curr Neurol Neurosci Rep. 2022 Dec;22(12):839-846. (PMID: 36434488)
J Cogn Neurosci. 2010 Nov;22(11):2491-502. (PMID: 19925193)
Sci Rep. 2025 Sep 29;15(1):33667. (PMID: 41023148)
J Clin Neurophysiol. 2019 Nov;36(6):460-466. (PMID: 31335565)
Sensors (Basel). 2025 Feb 05;25(3):. (PMID: 39943605)
Epilepsia. 2023 Sep;64(9):2351-2360. (PMID: 37350392)
Sensors (Basel). 2025 Aug 21;25(16):. (PMID: 40872076)
Clin Neurophysiol. 2018 May;129(5):1056-1082. (PMID: 29483017)
Sensors (Basel). 2021 Oct 14;21(20):. (PMID: 34696039)
Neurol Int. 2025 Mar 24;17(4):. (PMID: 40278419)
Epilepsia. 2023 Mar;64(3):602-618. (PMID: 36762397)
Sci Rep. 2023 Oct 3;13(1):16589. (PMID: 37789022)
Clin Neurophysiol Pract. 2019 Mar 13;4:69-75. (PMID: 30976727)
Front Neurosci. 2021 Oct 18;15:748100. (PMID: 34733134)
Sensors (Basel). 2021 Jul 31;21(15):. (PMID: 34372446)
J Am Coll Emerg Physicians Open. 2024 Sep 13;5(5):e13303. (PMID: 39281726)
Sci Rep. 2020 Mar 23;10(1):5218. (PMID: 32251333)
Pract Neurol. 2024 Jan 23;24(1):2-10. (PMID: 38050141)
Sensors (Basel). 2019 Mar 19;19(6):. (PMID: 30893791)
Brain Behav. 2022 Feb;12(2):e2476. (PMID: 35040596)
Sensors (Basel). 2014 Jul 18;14(7):12847-70. (PMID: 25046013)
Clin Neurophysiol Pract. 2023 Mar 11;8:58-64. (PMID: 37033684)
Grant Information: no Cerebri GmbH
Contributed Indexing: Keywords: dry electrode; electroencephalography; electrophysiology; gel-free
Entry Date(s): Date Created: 20260414 Date Completed: 20260715 Latest Revision: 20260813
Update Code: 20260813
PubMed Central ID: PMC13074899
DOI: 10.3390/s26072146
PMID: 41977935
Βάση Δεδομένων: MEDLINE